The effect of electric field on potentiometric Scanning Electrochemical Microscopic imaging

被引:21
|
作者
Kiss, Andras [1 ,2 ]
Filotas, Daniel [1 ,2 ]
Souto, Ricardo M. [3 ]
Nagy, Geza [1 ,2 ]
机构
[1] Univ Pecs, Dept Gen & Phys Chem, Fac Sci, Ifjusag Utja 6, H-7624 Pecs, Hungary
[2] Univ Pecs, Janos Szentagothai Res Ctr, Ifjusag Utja 20, H-7624 Pecs, Hungary
[3] Univ La Laguna, Dept Chem, POB 456, E-38200 San Cristobal la Laguna, Tenerife, Spain
关键词
Scanning electrochemical microscopy; Potentiometry; Ion-selective microelectrode; Galvanic corrosion; Electric field; VIBRATING ELECTRODE; CONCENTRATION DISTRIBUTIONS; SELECTIVE MICROELECTRODES; AQUEOUS ENVIRONMENTS; SPATIAL-DISTRIBUTION; GALVANIC CORROSION; ALUMINUM; ZN2+;
D O I
10.1016/j.elecom.2017.03.011
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Potentiometric Scanning Electrochemical Microscopy (SECM) is a powerful tool in corrosion science. It allows the selective imaging of a particular ionic species released at the anodic sites in a corrosion micro cell, by using ion-selective microelectrodes (ISMEs) as scanning probes. Galvanic corrosion is a particularly often studied process. The measured potential of the ISME is thought to depend only on the activity of the primary ion. However, an electric field is also formed as a result of the potential difference between the surfaces of the galvanic pair, which has a direct influence on the potential of the sensing microelectrode; the measured potential is the sum of these two contributions. The potential difference caused by the electric field can be substantially large, exceeding that of the potential difference associated with the activity of the primary ion. In this paper, we present experimental evidence of this feature, and investigate the extent to which it influences the final chemically-resolved image. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 141
页数:4
相关论文
共 50 条
  • [1] Electric field effects in scanning tunnelingmicroscope imaging
    Stokbro, K.
    Quaade, U.
    Grey, F.
    Applied Physics A: Materials Science and Processing, 1998, 66 (SUPPL. 1):
  • [2] Electric field effects in scanning tunneling microscope imaging
    Stokbro, K
    Quaade, U
    Grey, F
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1998, 66 (Suppl 1): : S907 - S910
  • [3] Electric field effects in scanning tunneling microscope imaging
    K. Stokbro
    U. Quaade
    F. Grey
    Applied Physics A, 1998, 66 : S907 - S910
  • [4] Direct evidence of ionic fluxes across ion selective membranes:: A scanning electrochemical microscopic and potentiometric study
    Gyurcsányi, RE
    Pergel, E
    Nagy, R
    Kapui, I
    Lan, BTT
    Tóth, K
    Bitter, I
    Lindner, E
    ANALYTICAL CHEMISTRY, 2001, 73 (09) : 2104 - 2111
  • [5] MICROSCOPIC THEORY OF SCANNING TUNNELING MICROSCOPE FOR FINITE ELECTRIC-FIELD AND CURRENT
    HIROSE, K
    TSUKADA, M
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1994, 12 (03): : 2164 - 2166
  • [6] SCANNING ELECTROCHEMICAL MICROSCOPY - POTENTIOMETRIC PROBING OF ION FLUXES
    DENUAULT, G
    FRANK, MHT
    PETER, LM
    FARADAY DISCUSSIONS, 1992, 94 : 23 - 35
  • [7] Scanning gel electrochemical microscopy (SGECM): The potentiometric measurements
    Dang, Ning
    Etienne, Mathieu
    Walcarius, Alain
    Liu, Liang
    ELECTROCHEMISTRY COMMUNICATIONS, 2018, 97 : 64 - 67
  • [8] Near-field scanning optical microscopic imaging of cell membrane.
    Ianoul, A
    Grant, D
    Pezacki, J
    Johnston, L
    BIOPHYSICAL JOURNAL, 2004, 86 (01) : 334A - 334A
  • [9] Combined amperometric/potentiometric probes for improved chemical imaging of corroding surfaces using Scanning Electrochemical Microscopy
    Filotas, D.
    Fernandez-Perez, B. M.
    Izquierdo, J.
    Nagy, L.
    Nagy, G.
    Souto, R. M.
    ELECTROCHIMICA ACTA, 2016, 221 : 48 - 55
  • [10] Nanoscale electric field imaging with an ambient scanning quantum sensor microscope
    Qiu, Ziwei
    Hamo, Assaf
    Vool, Uri
    Zhou, Tony X.
    Yacoby, Amir
    NPJ QUANTUM INFORMATION, 2022, 8 (01)