A safe procedure for connecting a continuous renal replacement therapy device into an extracorporeal membrane oxygenation circuit

被引:29
|
作者
Suga, Natsumi [1 ]
Matsumura, Yosuke [1 ]
Abe, Ryuzo [1 ]
Hattori, Noriyuki [1 ]
Nakada, Taka-aki [1 ]
Oda, Shigeto [1 ]
机构
[1] Chiba Univ, Dept Emergency & Crit Care Med, Grad Sch Med, Chuo Ku, 1-8-1 Inohana, Chiba 2608677, Japan
关键词
Extracorporeal membrane oxygenation; Continuous renal replacement therapy; Adult; Pressure; Bypass conduit; CRITICALLY-ILL PATIENTS; LIFE-SUPPORT; FAILURE; ECMO;
D O I
10.1007/s10047-017-0952-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Patients receiving extracorporeal membrane oxygenation (ECMO) often require continuous renal replacement therapy (CRRT). The intra-circuit pressure of adult ECMO usually deviates from the physiological range. We investigated the use of CRRT connected to an ECMO circuit with physiological intra-circuit pressures (0-150 mmHg, defined as the "safety range") using an in vitro experiment involving a water-filled ECMO circuit. The intra-circuit pressure pre-pump, post-pump, and post-oxygenator were measured while varying the height of the pump or ECMO flow. The bypass conduit pressure and distance from the post-oxygenator port were measured to find the "safety point", where the bypass pressure remained within the safety range. Both drainage and return limbs of the CRRT machine were connected to the safety point and the inlet and outlet pressures of the hemofilter were recorded while varying the ECMO and CRRT flow. The pre-pump pressure only remained within the safety range for heights >75 cm (ECMO flow = 4 L/min) or ECMO flow <3.5 L min (height = 50 cm). The post-pump and post-oxygenator pressure was generally outside of the safety range. The bypass pressure decreased according to the distance from the post-oxygenator port and the safety point was found at 60 or 75 cm (in a 90-cm length conduit) regardless of ECMO flow. The hemofilter inlet and outlet pressures remained within the safety range for all conditions of ECMO and CRRT flow, findings validated in clinical cases. The bypass conduit within an ECMO circuit can be connected to a CRRT machine safely under physiological pressures in adult patients receiving ECMO.
引用
收藏
页码:125 / 131
页数:7
相关论文
共 50 条
  • [1] A safe procedure for connecting a continuous renal replacement therapy device into an extracorporeal membrane oxygenation circuit
    Natsumi Suga
    Yosuke Matsumura
    Ryuzo Abe
    Noriyuki Hattori
    Taka-aki Nakada
    Shigeto Oda
    [J]. Journal of Artificial Organs, 2017, 20 : 125 - 131
  • [2] Impact of connecting continuous renal replacement therapy to the extracorporeal membrane oxygenation circuit
    De Tymowski, Christian
    Desmard, Mathieu
    Lortat-Jacob, Brice
    Pellenc, Quentin
    Alkhoder, Soleiman
    Alouache, Arezki
    Fritz, Benedicte
    Montravers, Philippe
    Augustin, Pascal
    [J]. ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2018, 37 (06) : 557 - 564
  • [3] Using additional pressure control lines when connecting a continuous renal replacement therapy device to an extracorporeal membrane oxygenation circuit
    Na, Soo Jin
    Choi, Hee Jung
    Chung, Chi Ryang
    Cho, Yang Hyun
    Jang, Hye Ryoun
    Suh, Gee Young
    Jeon, Kyeongman
    [J]. BMC NEPHROLOGY, 2018, 19
  • [4] Using additional pressure control lines when connecting a continuous renal replacement therapy device to an extracorporeal membrane oxygenation circuit
    Soo Jin Na
    Hee Jung Choi
    Chi Ryang Chung
    Yang Hyun Cho
    Hye Ryoun Jang
    Gee Young Suh
    Kyeongman Jeon
    [J]. BMC Nephrology, 19
  • [5] Connecting continuous renal replacement therapy in parallel with extracorporeal membrane oxygenation: is there no problem? Reply
    Lopez-Herce, Jesus
    Jose Santiago, Maria
    Sanchez, Amelia
    [J]. KIDNEY INTERNATIONAL, 2010, 77 (09) : 830 - 830
  • [6] Continuous Renal Replacement Therapy during Extracorporeal Membrane Oxygenation: Circuit Haemodynamics and Circuit Failure
    Sansom, Benjamin
    Riley, Brooke
    Udy, Andrew
    Sriram, Shyamala
    Presneill, Jeffrey
    Bellomo, Rinaldo
    [J]. BLOOD PURIFICATION, 2023, 52 (06) : 522 - 531
  • [7] Continuous renal replacement therapy in patients with extracorporeal membrane oxygenation
    Poveda, Ricardo
    Fajardo, Christian
    Agliati, Rocio
    Diaz, Rodrigo
    [J]. REVISTA MEDICA DE CHILE, 2018, 146 (01) : 78 - 90
  • [8] Combination of extracorporeal membrane oxygenation and continuous renal replacement therapy
    Yarosh, R. G.
    Piatrovich, N. S.
    Shestakova, L. G.
    Ostrovsky, Y. P.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 : 612 - 613
  • [9] Impact of connecting methods of continuous renal replacement therapy device on patients underwent extracorporeal membrane oxygenation: A retrospectively observational study
    Wu, Juan
    Huang, Xihua
    Mei, Yong
    Lv, Jinru
    Li, Wei
    Hu, Deliang
    Zhang, Gang
    Zhang, Huazhong
    Gao, Yongxia
    Zhang, Hui
    Chen, Xufeng
    Sun, Feng
    [J]. AUSTRALIAN CRITICAL CARE, 2023, 36 (05) : 695 - 701
  • [10] Providing Continuous Renal Replacement Therapy in Patients on Extracorporeal Membrane Oxygenation
    Karakala, Nithin
    Juncos, Luis A.
    [J]. CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2020, 15 (05): : 704 - 706