Heterogeneous sensor arrays: Merging cameras and gas sensors into innovative fire detection systems

被引:16
|
作者
Hackner, Angelika [1 ]
Oberpriller, Helmut [1 ]
Ohnesorge, Alexander [1 ]
Hechtenberg, Volker [2 ]
Mueller, Gerhard [1 ,3 ]
机构
[1] Airbus Grp Innovat, D-81663 Munich, Germany
[2] Innovat Team Bremen, D-17111 Meesiger, Germany
[3] Munich Univ Appl Sci, Fachbereich 06, Lothstr 34, D-80335 Munich, Germany
关键词
Multi-criteria fire detection; Image processing; Gas detection; False alarm rate; Alarm verification;
D O I
10.1016/j.snb.2016.02.081
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An innovative way of multi-criteria fire detection is introduced. In this concept image information about the monitored area is combined with knowledge about the reactive gas concentrations inside this same area to produce a fire alarm and to enable alarm verification. Key component in this new mode of fire detection is a low-cost CCD camera which is operated in a difference image (DI) mode. In the unsupervised DI mode, the average grey scale values in consecutive difference images are evaluated and compared with the outputs of a metal oxide gas sensor array which measures the reactive gas concentrations in this same area. Fire alarms are generated upon observing concurrent changes in all sensor outputs. Once obtained, the camera can be switched to the supervised imaging mode and the validity of an alarm can be assessed by normal and/or difference imaging of the monitored area. In this paper the concept of DI-based fire detection is explained, demonstrated and possible enhancements and ramifications of this new technique are discussed. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:497 / 505
页数:9
相关论文
共 50 条
  • [1] Fire detection with temperature sensor arrays
    Kaiser, T
    34TH ANNUAL 2000 INTERNATIONAL CARNAHAN CONFERENCE ON SECURITY TECHNOLOGY, PROCEEDINGS, 2000, : 262 - 268
  • [2] Early fire detection based on gas sensor arrays: Multivariate calibration and validation
    Solorzano, Ana
    Eichmann, Jens
    Fernandez, Luis
    Ziems, Bernd
    Manuel Jimenez-Soto, Juan
    Marco, Santiago
    Fonollosa, Jordi
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 352
  • [3] Sensor arrays with metal-oxide gas sensors for gas detection and determination of gas concentrations in real time
    Mayer, H
    TECHNISCHES MESSEN, 1998, 65 (02): : 58 - 71
  • [4] Gas sensor technologies for fire detection
    Gutmacher, D.
    Hoefer, U.
    Woellenstein, J.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 175 : 40 - 45
  • [5] Fire detection using smoke and gas sensors
    Chen, Shin-Juh
    Hovde, David C.
    Peterson, Kristen A.
    Marshall, Andre W.
    FIRE SAFETY JOURNAL, 2007, 42 (08) : 507 - 515
  • [6] Fire detection systems by compact electronic nose systems using metal oxide gas sensors
    Charumporn, B
    Omatu, S
    Yoshioka, M
    Fujinaka, T
    Kosaka, T
    2004 IEEE INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS, VOLS 1-4, PROCEEDINGS, 2004, : 1317 - 1320
  • [7] Compact electronic nose systems using metal oxide gas sensors for fire detection systems
    Charumporn, Bancha
    Fujinaka, Toru
    Yoshioka, Michifumi
    Omatu, Sigeru
    2006 IEEE INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORK PROCEEDINGS, VOLS 1-10, 2006, : 2214 - +
  • [8] Comparison of gas sensor technologies for fire gas detection
    Gutmacher, D.
    Foelmli, C.
    Vollenweider, W.
    Hoefer, U.
    Woellenstein, J.
    EUROSENSORS XXV, 2011, 25
  • [9] Gas sensor arrays using selective chemical sensors.
    Zhou, HW
    Gouma, PI
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 226 : U575 - U575
  • [10] Fire detection with low power fet gas sensors
    Pohle, R.
    Simon, E.
    Schneider, R.
    Fleischer, M.
    Sollacher, R.
    Gao, H.
    Mueller, K.
    Jauch, P.
    Loepfe, M.
    Frerichs, H. -P.
    Wilbertz, C.
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 120 (02) : 669 - 672