Patient-specific quality assurance method for VMAT treatment delivery

被引:112
|
作者
Schreibmann, Eduard [1 ]
Dhabaan, Anees [1 ]
Elder, Eric [1 ]
Fox, Tim [1 ]
机构
[1] Emory Univ, Sch Med, Dept Radiat Oncol, Atlanta, GA 30322 USA
关键词
CONE-BEAM CT; A-SI EPIDS; DOSE RECONSTRUCTION; RADIATION-THERAPY; MLC; CALIBRATION; IMRT; VERIFICATION; RAPIDARC; ARC;
D O I
10.1118/1.3213085
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Volumetric modulated arc therapy (VMAT) is a system for intensity-modulated radiotherapy treatment delivery that achieves high dose conformality by optimizing the dose rate, gantry speed, and the leaf positions of the dynamic multileaf collimator (DMLC). The aim of this work is to present a practical approach for patient-specific volumetric reconstruction of the dose delivered of a VMAT treatment using the DMLC and treatment controller log (Dynalog) files. The accuracy of VMAT delivery was analyzed for five prostate patients. For each patient, a clinical treatment was delivered and values recorded in the log files for the gantry angle, dose rate, and leaf positions were converted to a new DICOM-compliant plan using a custom-developed software system. The plan was imported in a treatment planning system and the dose distribution was recreated on the original CT by simply recomputing the dose. Using the standard evaluation tools, it is straightforward to assess if reconstructed dose meets clinical endpoints, as well as to compare side-by-side reconstructed and original plans. The study showed that log files can be directly used for dose reconstruction without resorting to phantom measurements or setups. In all cases, analysis of the leaf positions showed a maximum error of -0.26 mm (mean of 0.15 mm). Gantry angle deviation was less than 1 S and the total MU was within 0.5 from the planned value. Differences between the reconstructed and the intended dose matrices were less than 1.46% for all cases. Measurements using the MATRIXX system in a phantom were used to validate the dosimetric accuracy of the proposed method, with an agreement of at least 96% in all pixels as measured using the gamma index. The methodology provides a volumetric evaluation of the dose reconstructed by VMAT plans which is easily achieved by automated analysis of Dynalog files without additional measurements or phantom setups. This process provides a valuable platform for adaptive therapy in the future. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3213085]
引用
收藏
页码:4530 / 4535
页数:6
相关论文
共 50 条
  • [1] Volumetric Patient-Specific Quality Assurance for VMAT Treatment Delivery Using the Dynalog Files
    Schreibmann, E.
    Dhabaan, A.
    Elder, E.
    Fox, T.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [2] Using an EPID for patient-specific VMAT quality assurance
    Bakhtiari, M.
    Kumaraswamy, L.
    Bailey, D. W.
    de Boer, S.
    Malhotra, H. K.
    Podgorsak, M. B.
    MEDICAL PHYSICS, 2011, 38 (03) : 1366 - 1373
  • [3] Results of a Provincial Survey on Patient-Specific Quality Assurance Practice for IMRT and VMAT Delivery
    King, Jenna
    Abdellatif, Ady
    Bissonnette, Jean-Pierre
    Buckley, Lesley
    Chan, Gordon
    Chin, Lee
    Comsa, Daria
    Himmelman, Julie
    Rapley, Patrick
    Vandermeer, Aaron
    MEDICAL PHYSICS, 2019, 46 (11) : 5377 - 5377
  • [4] Survey of patient-specific quality assurance practice for IMRT and VMAT
    Chan, Gordon H.
    Chin, Lee C. L.
    Abdellatif, Ady
    Bissonnette, Jean-Pierre
    Buckley, Lesley
    Comsa, Daria
    Granville, Dal
    King, Jenna
    Rapley, Patrick L.
    Vandermeer, Aaron
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (07): : 155 - 164
  • [5] Best Practice Guidance for Patient-Specific Quality Assurance for IMRT and VMAT Plan Delivery Verification
    Chan, G.
    Abdellatif, A.
    Bissonnette, J.
    Chin, L.
    Comsa, D.
    Granville, D.
    Himmelman, J. Kraus
    King, J.
    Rapley, P.
    Vandermeer, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E506 - E506
  • [6] Patient-Specific Quality Assurance for Breast VMAT Treatment without Measurements Using Radcalc Software
    Petit, R.
    Apaza, O.
    Bohorquez, L. C.
    Wolfsberger, D.
    Diaz Moreno, R.
    Almada, M. J.
    Venencia, C. D.
    MEDICAL PHYSICS, 2024, 51 (10) : 7884 - 7884
  • [7] Machine Learning for Patient-Specific Quality Assurance of VMAT: Prediction and Classification Accuracy
    Li, J.
    Wang, L.
    Zhang, X.
    Liu, L.
    Li, J.
    Chan, M.
    Sui, J.
    Yang, R.
    MEDICAL PHYSICS, 2019, 46 (06) : E497 - E497
  • [8] Evaluation of digital linac log data for patient-specific VMAT quality assurance
    U'wais, F.
    Zin, H. M.
    Radzi, Y.
    Rizan, N. N.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1346 - S1346
  • [9] Machine Learning for Patient-Specific Quality Assurance of VMAT: Prediction and Classification Accuracy
    Li, Jiaqi
    Wang, Le
    Zhang, Xile
    Liu, Lu
    Li, Jun
    Chan, Maria F.
    Sui, Jing
    Yang, Ruijie
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (04): : 893 - 902
  • [10] Use of a plastic scintillator detector for patient-specific quality assurance of VMAT SRS
    Snyder, Jesse D.
    Sullivan, Rodney J.
    Wu, Xingen
    Covington, Elizabeth L.
    Popple, Richard A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (09): : 143 - 148