Equivalent Uniform Dose Inverse Treatment Planning for Dynamic Arc Radiotherapy of Prostate Carcinoma

被引:0
|
作者
Mihaylov, I. B. [1 ]
Lerma, F. A. [2 ]
Bzdusek, K. [3 ]
Penagaricano, J. [1 ]
Gardner, K. [1 ]
Ratanatharathorn, V. [1 ]
Moros, E. G. [1 ]
机构
[1] Univ Arkansas Med Sci, Little Rock, AR 72205 USA
[2] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
[3] Philips Med Syst, Fitchburg, WI USA
关键词
D O I
10.1016/j.ijrobp.2009.07.1666
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
引用
收藏
页码:S731 / S732
页数:2
相关论文
共 50 条
  • [1] From physical dose constraints to equivalent uniform dose constraints in inverse radiotherapy planning
    Thieke, C
    Bortfeld, T
    Niemierko, A
    Nill, S
    [J]. MEDICAL PHYSICS, 2003, 30 (09) : 2332 - 2339
  • [2] Designing equivalent treatment regimens for prostate radiotherapy based on equivalent uniform dose
    Li, X. A.
    Wang, J. Z.
    Stewart, R. D.
    Dibiase, S. J.
    Wang, D.
    Lawton, C. A.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (961): : 59 - 68
  • [3] Equivalent uniform dose as a predictor of acute toxicity in prostate radiotherapy
    Levin-Plotnik, D
    Hamilton, R
    Myrianthopoulos, L
    Turian, J
    Vijayakumar, S
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1248 - 1248
  • [4] Regularization and the L-curve for inverse planning based on equivalent uniform dose
    Chvetsov, A.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2134 - 2134
  • [5] Benefit of Equivalent Uniform Dose in Prostate IMRT Planning to Reduce Bladder Toxicity
    Zhu, J.
    Simon, A.
    Haigron, P.
    Lafond, C.
    Acosta, O.
    Shu, H.
    Castelli, J.
    Li, B.
    De Crevoisier, R.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3236 - 3236
  • [6] Equivalent uniform dose (EUD) based optimization for IMRT treatment planning
    Mihailidis, D.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2295 - 2295
  • [7] The benefit of using bladder sub-volume equivalent uniform dose constraints in prostate intensity-modulated radiotherapy planning
    Zhu, Jian
    Simon, Antoine
    Haigron, Pascal
    Lafond, Caroline
    Acosta, Oscar
    Shu, Huazhong
    Castelli, Joel
    Li, Baosheng
    De Crevoisier, Renaud
    [J]. ONCOTARGETS AND THERAPY, 2016, 9 : 7537 - 7544
  • [8] Method for using biological imaging data to modulate equivalent uniform dose based inverse planning
    Wiesmeyer, MD
    Beavis, AW
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1335 - 1335
  • [9] Evaluation of external beam radiotherapy and brachytherapy for localized prostate cancer using equivalent uniform dose
    Wang, JZ
    Li, XA
    [J]. MEDICAL PHYSICS, 2003, 30 (01) : 34 - 40
  • [10] VARIATIONS IN BLADDER VOLUME AND EQUIVALENT UNIFORM DOSE FOR PROSTATE CANCER PATIENTS RECEIVING EXTERNAL RADIOTHERAPY
    Hvaale, S.
    Hydal, J. B.
    Fallmyr, I.
    Jorgensen, K.
    Nilsskog, R. A. H.
    Bo, B.
    Malinen, E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S184 - S184