Evaluation of the catheter positioning for neurally adjusted ventilatory assist

被引:90
|
作者
Barwing, Jurgen [1 ]
Ambold, Markus [1 ]
Linden, Nadine [1 ]
Quintel, Michael [1 ]
Moerer, Onnen [1 ]
机构
[1] Univ Gottingen, Dept Anaesthesiol, D-37075 Gottingen, Germany
关键词
Neurally adjusted ventilatory assist (NAVA); Neural control; Electrical activation of the diaphragm (EAdi); BARDET-BIEDL-SYNDROME; MECHANICAL VENTILATION; SYNCHRONY; DIAPHRAGM; RABBITS;
D O I
10.1007/s00134-009-1587-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
During neurally adjusted ventilatory assist (NAVA) the ventilator is driven by the patients electrical activation of the diaphragm (EAdi), detected by a special esophageal catheter. A reliable positioning of the EAdi-catheter is mandatory to trace a representative EAdi signal. We aimed to determine whether a formula that is based on the measurement from nose to ear lobe to xiphoid process of the sternum (NEX distance) modified for EAdi-catheter placement (NEXmod) is sufficient for predicting the accurate catheter position. Twenty-six patients were enrolled in this study. The optimal EAdi-catheter position (OPT) was defined by: (1) stable EAdi signal, (2) electrical activity highlighted in central leads of the catheter positioning tool, and (3) absence of p-wave in distal lead. Afterwards NEXmod was calculated and compared to the OPT finding. At NEXmod the EAdi signal was suitable for running NAVA in 18 out of 25 patients (72%). NEXmod was identical with OPT in four patients (16%). NAVA was possible in all patients at OPT. Median OPT position was 2 cm caudal of the NEXmod ranging from 3 cm too cranial to a position 12 cm too caudal (P < 0.01). In one patient excluded from further analysis EAdi-catheter placement led to the diagnosis of bilateral injury of the phrenic nerves. EAdi-catheter placement based on the NEXmod formula allows running NAVA in about two-thirds of all patients. The additional tools provided are efficient and facilitate the correct positioning of the EAdi-catheter for neurally adjusted ventilatory assist.
引用
收藏
页码:1809 / 1814
页数:6
相关论文
共 50 条
  • [1] Evaluation of the catheter positioning for neurally adjusted ventilatory assist
    Jürgen Barwing
    Markus Ambold
    Nadine Linden
    Michael Quintel
    Onnen Moerer
    [J]. Intensive Care Medicine, 2009, 35 : 1809 - 1814
  • [2] Neurally adjusted ventilatory assist catheter entering the pleural cavity
    Kant, M.
    Hol, M.
    Spronk, P. E.
    [J]. NETHERLANDS JOURNAL OF CRITICAL CARE, 2020, 28 (04): : 180 - 182
  • [3] Neurally adjusted ventilatory assist
    Navalesi, Paolo
    Longhini, Federico
    [J]. CURRENT OPINION IN CRITICAL CARE, 2015, 21 (01) : 58 - 64
  • [4] NEURALLY ADJUSTED VENTILATORY ASSIST (NAVA)
    Clemente Lopez, Francisco Jose
    [J]. REVISTA ROL DE ENFERMERIA, 2014, 37 (10): : 674 - 678
  • [5] Neurally Adjusted Ventilatory Assist - NAVA
    de Carvalho, Werther Brunow
    Machado Fonseca, Marcelo Cunio
    [J]. CURRENT RESPIRATORY MEDICINE REVIEWS, 2012, 8 (01) : 37 - 43
  • [6] Neurally adjusted ventilatory assist: An update
    Garzando, Mar
    Ferrandis, Raquel
    Garrigues, Beatriz
    Soro, Marina
    Javier Belda, F.
    [J]. TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2014, 4 (04) : 115 - 118
  • [7] Neurally Adjusted Ventilatory Assist in Newborns
    Beck, Jennifer
    Sinderby, Christer
    [J]. CLINICS IN PERINATOLOGY, 2021, 48 (04) : 783 - 811
  • [8] Influence of body position, PEEP and intra-abdominal pressure on the catheter positioning for neurally adjusted ventilatory assist
    Barwing, Juergen
    Pedroni, Cristina
    Quintel, Michael
    Moerer, Onnen
    [J]. INTENSIVE CARE MEDICINE, 2011, 37 (12) : 2041 - 2045
  • [9] Influence of body position, PEEP and intra-abdominal pressure on the catheter positioning for neurally adjusted ventilatory assist
    Jürgen Barwing
    Cristina Pedroni
    Michael Quintel
    Onnen Moerer
    [J]. Intensive Care Medicine, 2011, 37 : 2041 - 2045
  • [10] Proportional Assist Ventilation and Neurally Adjusted Ventilatory Assist
    Kacmarek, Robert M.
    [J]. RESPIRATORY CARE, 2011, 56 (02) : 140 - 148