Novel Method for Real Time Co-Registration of IVUS and Coronary Angiography

被引:12
|
作者
Frimerman, Aharon [1 ]
Abergel, Eitan [2 ]
Blondheim, David S. [1 ]
Shotan, Avraham [1 ]
Meisel, Simcha [1 ]
Shochat, Michael [1 ]
Punjabi, Pritesh [2 ]
Roguin, Ariel [2 ]
机构
[1] Hillel Yaffe Med Ctr, Dept Cardiol, IL-38100 Hadera, Israel
[2] Technion Israel Inst Technol, Rappaport Fac Med, Rambam Med Ctr, Dept Cardiol, IL-3109601 Haifa, Israel
关键词
INTRAVASCULAR ULTRASOUND; FUSION; IMPACT;
D O I
10.1111/joic.12279
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesWe present our experience with a novel method for real time co-registration of intravascular ultrasound (IVUS) and coronary angiography. BackgroundA major limitation of the current practice of concomitant use of coronary angiography and IVUS is that the locations of the acquired IVUS images are not correlated with their exact locations on the vessel roadmap obtained by coronary angiography. MethodsPhantoms simulating the coronary tree were used to test the accuracy and potential of co-registration. Subsequently we examined patients who underwent IVUS during cardiac catheterization. Analysis and feasibility were performed in 42 arteries of 36 patients. ResultsThe statistical validation in phantoms resulted in a co-registration accuracy of 1.12mm. The length measurement on an angiogram resulted in an accuracy of 0.38mm. Co-registration in patients was successful in all cases and four categories were assisted by 1(bad) to 5 (good) grading. Accuracy (the co-registration precision in pointing at the exact corresponding location): 4.80.41; Ease of use and workflow: 4.74 +/- 0.44; Stent landing zone detection and evaluation: 4.58 +/- 0.5; Stent landing zone length and diameter measurement: 4.94 +/- 0.23. The co-registration error was estimated as no more than 1mm. ConclusionIn this pilot study, we found that the novel IVUS and coronary angiography co-registration method is accurate, easy to use, fast and user-friendly. This method precludes the need to use motorized automated pull back device. (J Interven Cardiol 2016;29:225-231)
引用
收藏
页码:225 / 231
页数:7
相关论文
共 50 条
  • [1] Validation of a new angiography/IVUS co-registration system
    Houissa, K.
    Escaned, J.
    Macaya, C.
    Cruden, N. L.
    Uren, N.
    Slots, T.
    Carlier, S.
    [J]. EUROPEAN HEART JOURNAL, 2016, 37 : 490 - 491
  • [2] A new method for real-time co-registration of 3D coronary angiography and intravascular ultrasound or optical coherence tomography
    Carlier, Stephane
    Didday, Rich
    Slots, Tristan
    Kayaert, Peter
    Sonck, Jeroen
    El-Mourad, Mike
    Preumont, Nicolas
    Schoors, Dany
    Van Camp, Guy
    [J]. CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2014, 15 (04) : 226 - 232
  • [3] COMPUTED TOMOGRAPHY ANGIOGRAPHY CO-REGISTRATION WITH REAL-TIME FLUOROSCOPY IN CHRONIC TOTAL OCCLUSION PERCUTANEOUS CORONARY INTERVENTIONS
    Xenogiannis, Iosif
    Burke, M. Nicholas
    Megaly, Michael
    Hall, Allison B.
    Tajti, Peter
    Morley, Pamela W.
    Rangan, Bavana
    Brilakis, Emmanouil S.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1074 - 1074
  • [4] Computed tomography angiography co-registration with real-time fluoroscopy in percutaneous coronary intervention for chronic total occlusions
    Xenogiannis, Iosif
    Jaffer, Farouc A.
    Shah, Alpesh R.
    Omer, Mohamed
    Megaly, Michael
    Vemmou, Evangelia
    Nikolakopoulos, Ilias
    V. Rangan, Bavana
    Garcia, Santiago
    Lesser, John R.
    Cavalcante, Joao L.
    Burke, Nicholas
    Brilakis, Emmanouil S.
    [J]. EUROINTERVENTION, 2021, 17 (05) : E433 - E435
  • [5] Comprehensive assessment of multivessel disease with physiological vessel mapping and IVUS-angiography co-registration
    Dingli, Philip
    Ryan, Nicola
    Escaned, Javier
    [J]. EUROPEAN HEART JOURNAL-CASE REPORTS, 2018, 2 (01)
  • [6] Automated co-registration of coronary CT angiography with myocardial perfusion SPECT
    Woo, Jonghye
    Slomka, Piotr
    Kuo, C-C
    Cheng, Victor
    Dey, Damini
    Ramesh, Amit
    Herman, Daniel
    Germano, Guido
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [7] Co-registration of Intravascular Ultrasound and Angiography
    Cassar, Andrew
    Prasad, Megha
    Fetterly, Kenneth A.
    Prasad, Abhiram
    Bresnahan, John
    Lerman, Amir
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B197 - B197
  • [8] The OPTIS Integrated System: real-time, co-registration of angiography and optical coherence tomography
    van der Sijde, Johannes N.
    Guagliumi, Giulio
    Sirbu, Vasile
    Shimamura, Kunihiro
    Borghesi, Marco
    Karanasos, Antonios
    Regar, Evelyn
    [J]. EUROINTERVENTION, 2016, 12 (07) : 855 - 860
  • [9] ASSESSMENT OF CO-REGISTRATION BETWEEN 3D ANGIOGRAPHY AND IVUS. AN IN VIVO FEASABILITY STUDY
    Ligthart, Jurgen
    Witberg, Karen
    Slots, Tristan
    Karanasos, Antonios
    Regar, Evelyn
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1790 - A1790
  • [10] Real-time optical coherence tomography co-registration with angiography to optimize percutaneous coronary intervention: results of the OPTICO-Integration study
    Steinbeck, L.
    Riedel, M.
    Staehli, B.
    Froehlich, C.
    Lauten, A.
    Skurk, C.
    Mochmann, H. C.
    Luebking, L.
    Rauch-Kroehnert, U.
    Schnabel, R.
    Westermann, D.
    Blankenberg, S.
    Landmesser, U.
    Leistner, D.
    [J]. EUROPEAN HEART JOURNAL, 2017, 38 : 473 - 473