Pulse oximetry for perioperative monitoring

被引:56
|
作者
Pedersen, Tom [1 ]
Moller, Ann Merete [2 ]
Hovhannisyan, Karen [3 ]
机构
[1] Rigshosp, Head & Orthopaed Ctr, DK-2100 Copenhagen O, Denmark
[2] Herlev Univ Hosp, Dept Anaesthesiol, DK-2730 Herlev, Denmark
[3] Rigshosp, Cochrane Anaesthesia Review Grp, DK-2100 Copenhagen O, Denmark
关键词
Oximetry; Anoxia [diagnosis; Monitoring; Intraoperative; methods; Postoperative Complications [prevention & control; Randomized Controlled Trials as Topic; Humans; POSTOPERATIVE COGNITIVE DYSFUNCTION; CLOSED CLAIMS ANALYSIS; CONTROLLED VENTILATION; SURGICAL PATIENTS; RECOVERY ROOM; SINGLE-BLIND; ANESTHESIA; HYPOXEMIA; COMPLICATIONS; EVENTS;
D O I
10.1002/14651858.CD002013.pub2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Back ground Pulse oximetry is extensively used in the perioperative period and might improve patient outcomes by enabling an early diagnosis and, consequently, correction of perioperative events that might cause postoperative complications or even death. Only a few randomized clinical trials of pulse oximetry during anaesthesia and in the recovery room have been performed that describe perioperative hypoxaemic events, postoperative cardiopulmonary complications, and cognitive dysfunction. Objectives The objective of this review was to assess the effects of perioperative monitoring with pulse oximetry and to clearly identify the adverse outcomes that might be prevented or improved by the use of pulse oximetry. Search strategy We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2009, Issue 2), MEDLINE (1966 to May 2009), EMBASE (1980 to May 2009), CINAHL (1982 to May 2009), ISI Web of Science (1956 to May 2009), LILACS (1982 to May 2009), and databases of ongoing trials; and checked the reference lists of trials and review articles. Selection criteria We included all controlled trials that randomized patients to either pulse oximetry or no pulse oximetry during the perioperative period. Data collection and analysis Two authors independently assessed data in relation to events detectable by pulse oximetry, any serious complications that occurred during anaesthesia or in the postoperative period, and intra- or postoperative mortality. Main results Searching identified five reports. We considered the studies with data from a total of 22,992 patients that were eligible for analysis. Results indicated that hypoxaemia was reduced in the pulse oximetry group, both in the operating theatre and in the recovery room. During observation in the recovery room, the incidence of hypoxaemia in the pulse oximetry group was 1.5 to three times less. Postoperative cognitive function was independent of perioperative monitoring with pulse oximetry. The one study in general surgery showed that postoperative complications occurred in 10% of the patients in the oximetry group and in 9.4% in the control group. No statistically significant differences were detected in cardiovascular, respiratory, neurologic, or infectious complications in the two groups. The duration of hospital stay was a median of five days in both groups, and an equal number of in-hospital deaths was registered in the two groups. Continuous pulse oximetry has the potential to increase vigilance and decrease pulmonary complications after cardiothoracic surgery, however routine continuous monitoring did not reduce transfer to an intensive care unit (ICU) or overall mortality. Authors' conclusions The studies confirmed that pulse oximetry can detect hypoxaemia and related events. However, we have found no evidence that pulse oximetry affects the outcome of anaesthesia for patients. The conflicting subjective and objective results of the studies, despite an intense methodical collection of data from a relatively large general surgery population, indicate that the value of perioperative monitoring with pulse oximetry is questionable in relation to improved reliable outcomes, effectiveness, and efficiency. Routine continuous pulse oximetry monitoring did not reduce either transfer to ICU or mortality, and it is unclear if there is any real benefit from the application of this technology in patients who are recovering from cardiothoracic surgery in a general care area.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Pulse Oximetry for Perioperative Monitoring
    Lemanski, Christina
    JOURNAL OF PERIANESTHESIA NURSING, 2016, 31 (01) : 86 - 88
  • [2] Pulse oximetry for perioperative monitoring
    Pedersen, Tom
    Nicholson, Amanda
    Hovhannisyan, Karen
    Moller, Ann Merete
    Smith, Andrew F.
    Lewis, Sharon R.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2014, (03):
  • [3] PERIOPERATIVE MONITORING WITH PULSE OXIMETRY AND LATE POSTOPERATIVE COGNITIVE DYSFUNCTION
    MOLLER, JT
    SVENNILD, I
    JOHANNESSEN, NW
    JENSEN, PF
    ESPERSEN, K
    GRAVENSTEIN, JS
    COOPER, JB
    DJERNES, M
    JOHANSEN, SH
    BRITISH JOURNAL OF ANAESTHESIA, 1993, 71 (03) : 340 - 347
  • [4] Pulse oximetry for Perioperative monitoring: Systematic review of randomized, controlled trials
    Pedersen, T
    Moller, AM
    Pedersen, BD
    ANESTHESIA AND ANALGESIA, 2003, 96 (02): : 426 - 431
  • [5] PERIOPERATIVE HYPOXEMIA DETECTED BY INTERMITTENT PULSE OXIMETRY
    MCKENZIE, AJ
    ANAESTHESIA AND INTENSIVE CARE, 1989, 17 (04) : 412 - 417
  • [6] Pulse oximetry and BIS monitoring
    Gage, JS
    ANESTHESIOLOGY, 2002, 96 (01) : 256 - 256
  • [7] FETAL MONITORING WITH PULSE OXIMETRY
    JOHNSON, N
    JOHNSON, VA
    FISHER, J
    JOBBINGS, B
    BANNISTER, J
    LILFORD, RJ
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1991, 98 (01): : 36 - 41
  • [8] MONITORING PERFUSION IN PULSE OXIMETRY
    GRIGG, KN
    ANAESTHESIA AND INTENSIVE CARE, 1988, 16 (03) : 377 - 378
  • [9] ANESTHESIA-RELATED HYPOXEMIA - THE EFFECT OF PULSE OXIMETRY MONITORING ON PERIOPERATIVE EVENTS AND POSTOPERATIVE COMPLICATIONS
    MOLLER, JT
    DANISH MEDICAL BULLETIN, 1994, 41 (05) : 489 - 500
  • [10] FETAL MONITORING BY PULSE OXIMETRY AND CTG
    MCNAMARA, H
    JOHNSON, N
    JOURNAL OF PERINATAL MEDICINE, 1993, 21 (06) : 475 - 480