In-training evaluation using hand-held computerized clinical work sampling strategies in radiology residency

被引:0
|
作者
Finlay, Karen
Norman, Geoff R.
Stolberg, Harald
Weaver, Bruce
Keane, David R.
机构
[1] McMaster Univ, Dept Clin Epidemiol & Biostat, Hamilton, ON L8N 3Z5, Canada
[2] McMaster Univ, Program Educ Res & Dev, Hamilton, ON L8N 3Z5, Canada
[3] McMaster Univ, Dept Diagnost Imaging, Hamilton, ON L8N 3Z5, Canada
[4] No Ontario Sch Med, Human Sci Div, Thunder Bay, ON, Canada
关键词
diagnostic radiology; resident evaluation; hand-held computers;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The in-training evaluation and final in-training evaluation are the mainstay format for evaluation summaries in Canadian residency training programs. This study investigates the feasibility of a clinical work sampling (CWS) approach to evaluation in radiology residency, with the aid of personal hand-held computing devices Methods: This study was conducted over a 1-year period with 14 radiology residents spanning 4 postgraduate years. Residents were provided with a hand-held device to enter evaluation data, with entries assessing 9 categories of resident performance. Results from the CWS entries were compared with standard in-training evaluations completed at the end of the residents' rotations, as well as with an established annual objective evaluation tool. Results: The overall reliability of the CWS approach according to the observed 7 forms per resident was 0.62, suggesting that a minimum of 20 forms would be required to achieve a reliability of 0.80. For the in-training evaluation report (ITER), internal consistency was 0.98, reflecting very high correlations between categories and indicating that the individual categories are not discriminating. Correlation across rotations was 0.36, which is low for summative evaluation. Correlation between the 2 measures was 0.47 (P = 0.09); neither measure was correlated with the American College of Radiology evaluation. Conclusion: The CWS strategy is feasible for adaptation to radiology residency, although compliance with voluntary entries was less than expected. It is not clear whether this reflects the additional burden of using the hand-held device, the fact that entries were voluntary rather than mandatory, or the many demands on both residents and evaluators. The added potential of this evaluation format includes the opportunity to discuss performance at the time of data entry, rather than resorting to the usual end-of-rotation evaluation. Nevertheless, the study has shown that the ITER remains only of marginal value for summative evaluation; the addition of the CWS would require at least 20 forms for acceptable reliability and might not justify the additional cost and complexity.
引用
收藏
页码:232 / 237
页数:6
相关论文
共 50 条
  • [1] Clinical work sampling: A new approach to the problem of in-training evaluation
    Turnbull J.
    MacFadyen J.
    Van Barneveld C.
    Norman G.
    Journal of General Internal Medicine, 2000, 15 (8) : 556 - 561
  • [2] PERKINS HAND-HELD APPLANATION TONOMETER - A CLINICAL EVALUATION
    WALLACE, J
    LOVELL, HG
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1968, 52 (07) : 568 - &
  • [3] Kinematic evaluation in Parkinson’s disease using a hand-held position transducer and computerized signal analysis
    S. Sauermann
    H. Standhardt
    W. Gerschlager
    H. Lanmüller
    F. Alesch
    Acta Neurochirurgica, 2005, 147 : 939 - 945
  • [4] Kinematic evaluation in Parkinson's disease using a hand-held position transducer and computerized signal analysis
    Sauermann, S
    Standhardt, H
    Gerschlager, W
    Lanmüller, H
    Alesch, F
    ACTA NEUROCHIRURGICA, 2005, 147 (09) : 939 - 945
  • [5] Clinical evaluation of postoperative pressure-induced alopecia using a hand-held dermatoscope
    Ozdemir, Emel Erturk
    Gulec, A. Tulin
    INTERNATIONAL JOURNAL OF DERMATOLOGY, 2014, 53 (04) : E309 - E310
  • [6] The clinical utility of a hand-held computerized optical imaging system at assessing skin discoloration
    Fisk, Nathan A.
    Jensen, Kurt
    Knaggs, Helen
    Ferguson, Scott
    JOURNAL OF COSMETIC DERMATOLOGY, 2010, 9 (02) : 103 - 107
  • [7] Kinematic evaluation in Parkinson's disease using a hand-held position transducer and computerized signal analysis - Comments
    Nikkhah, G
    Kim, DG
    ACTA NEUROCHIRURGICA, 2005, 147 (09) : 945 - 945
  • [8] CLINICAL-EVALUATION OF A HAND-HELD ULTRASOUND DEVICE IN PEDIATRIC CARDIOLOGY
    GUSSENHOVEN, WJ
    KAPPEN, L
    LIGTVOET, CM
    EGGINK, JH
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1980, 6 (03): : 271 - &
  • [9] Clinical evaluation of the eBsensor hand-held blood glucose monitoring system
    Chen, Chien-Chih
    Tai, Der-Yan
    Ho, Ping
    Lai, Yiu-Kay
    Lin, Jui-Jane
    Mao, Simon J. T.
    Lin, Chia-Chi
    Hsieh, Yu-Chen
    Chiang, Hsiang-Cheng
    Dai, Ken-Shwo
    CLINICA CHIMICA ACTA, 2007, 377 (1-2) : 170 - 173
  • [10] Emergency medicine resident patient care documentation using a hand-held computerized device
    Bird, SB
    Zarum, RS
    Renzi, FP
    ACADEMIC EMERGENCY MEDICINE, 2001, 8 (12) : 1200 - 1203