Partial discharge signals from TR-XLPE insulated cable

被引:0
|
作者
Morel, O [1 ]
Srinivas, N [1 ]
Berristein, B [1 ]
机构
[1] DTE Energy Technol Inc, Farmington Hills, MI USA
关键词
D O I
10.1109/ELINSL.2004.1380647
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper reports on signal measurements from an unaged TR-XLPE-insulated cable at constant voltage stress, prior to the onset of partial discharge, as conventionally measured in time domain technique. Although physical events prior to partial discharge have been studied in the past, very few reports exist on signal measurements under pre-partial discharge conditions. Signal intensity vs. (a) time at constant voltage, and (b) electrical tree length have been measured; signal intensity increases logarithmically with time, both prior to and after an electrical tree is observed. Tree retardant components in the insulation do not prevent such signals from appearing. Relevant reports have been summarized and relevance to aging phenomena are discussed.
引用
收藏
页码:466 / 470
页数:5
相关论文
共 50 条
  • [1] Cluster Analysis on Signals from XLPE Cable Partial Discharge Detection
    Liu Hui
    Chen Yufeng
    Shen Qinghe
    Yang Bo
    Sun Xiaobin
    Qi Zhao
    [J]. 2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014, : 1535 - 1540
  • [2] A comparative economic analysis for underground distribution cables insulated with TR-XLPE and EPR
    Ramachandran, S
    Hartlein, R
    Chandak, P
    [J]. 1999 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE, VOLS 1 & 2, 1999, : 112 - 119
  • [3] Advances in TR-XLPE insulation
    Caronia, PJ
    Furno, JS
    Pang, KP
    Szaniszlo, SR
    [J]. 1999 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE, VOLS 1 & 2, 1999, : 56 - 61
  • [4] Advances in TR-XLPE insulation
    Caronia, P.J.
    Furno, J.S.
    Pang, K.P.
    Szaniszlo, S.R.
    [J]. Proceedings of the IEEE Power Engineering Society Transmission and Distribution Conference, 1999, 1 : 56 - 61
  • [5] Research on Transmission Characteristics of Partial Discharge Signals in XLPE Cable Body
    Sun, Chunyu
    Tang, Zhiguo
    [J]. 2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 155 - 158
  • [6] Experimental study on relationships between partial discharge signals and apparent discharge magnitude in XLPE cable
    Wang, Wei
    Cheng, Xu
    Liu, Chong
    Zong, Fei
    Shen, Xueliang
    [J]. PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1183 - +
  • [7] Partial Discharge Measurement for Cable Terminators of XLPE Power Cable
    Apiratikul, P.
    Boonchiam, P.
    Plangklang, B.
    Suwanasri, T.
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 573 - 576
  • [8] Short circuit currents due to thermal instability on TR-XLPE 12/20 kV ground cable
    Abduh, Syamsir
    [J]. ICPASM 2005: Proceedings of the 8th International Conference on Properties and Applications of Dielectric Materials, Vols 1 and 2, 2006, : 869 - 872
  • [9] Partial Discharge Characteristics of a Defective MV XLPE Cable
    Ekasittiphong, Woraphat
    Smerpitak, Krit
    Tangthanam, Worasak
    Jeenmuang, Siwakorn
    Pattanadech, Norasage
    Pongswatd, Sawai
    [J]. Proceedings of the IEEE International Conference on Properties and Applications of Dielectric Materials, 2024, : 101 - 104
  • [10] Mechanical Fatigue as a Mechanism of Water Tree Propagation in TR-XLPE
    Wang, Zuoqian
    Marcolongo, Piero
    Lemberg, Joseph A.
    Panganiban, Brian
    Evans, James W.
    Ritchie, Robert O.
    Wright, Paul K.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (01) : 321 - 330