Portable microwave radiometer for wearable devices

被引:22
|
作者
Vesnin, Sergey G. [1 ,2 ,3 ]
Sedankin, Mikhail K. [4 ,5 ]
Ovchinnikov, Lev M. [2 ]
Gudkov, Alexander G. [1 ]
Leushin, Vitaly Yu [1 ]
Sidorov, Igor A. [1 ]
Goryanin, Igor I. [6 ]
机构
[1] Bauman Moscow State Tech Univ, 5,2nd Baumanskaya Str, Moscow 105005, Russia
[2] RES Co, 55-59 B1,B Pochtovaya, Moscow 105082, Russia
[3] RTM Diagnost LLC, 55-59 B1,B Pochtovaya, Moscow 105082, Russia
[4] SRC FMBC, 23 Marshala Novikova Str, Moscow 123098, Russia
[5] Dept Natl Res Univ, Moscow Power Engn Inst, 14 Krasnokazarmennaya Str, Moscow 111250, Russia
[6] Univ Edinburgh, 10 Crichton Str, Edinburgh EH8 9AR, Midlothian, Scotland
基金
俄罗斯科学基金会;
关键词
Microwave radiometer; Circuit parameters; Miniature radiometer; Core body temperature measurement; Temperature sensors; Wearable sensors; Non-invasive passive measurement; Body temperature monitoring; TEMPERATURE;
D O I
10.1016/j.sna.2020.112506
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new circuit of the miniature microwave radiometer for wearable devices, which can be used to monitor the core body temperature (CBT) of internal human tissues continuously 24/7. The measurement results of the proposed device, as opposed to the known miniature wearable radiometers, remain unchanged when the impedance of the examined area varies. We have derived an analytical expression for radiometer measurement error based on parameters of device components. This formula allows accuracies to be estimated and optimal parameters of the circuit to be selected to minimise measurement error at a design stage. It is shown that measurement error is independent of the antenna reflection coefficient and the temperature of the radiometer front-end. A prototype of the single-channel miniature radiometer has 32 x 25 x 14 mm(3) dimensions and USB interface communication with PC. A 28-h run of the device has shown that it is highly stable, and a maximum drift in temperature is 0.15 degrees C. Operating frequency range was 3400-4100 MHz, supply voltage -5 V; power supply of the radiometer in measurement mode is 210 mA; time constant of the radiometer without being averaged is 0.6 s, at the same time, standard deviation delta = 0.17 degrees C, with further averaging during 4 s delta = 0.052 degrees C, with averaging during 30 s delta = 0.017 degrees C; when there were input reflections R-2 = 0.25, an error in measuring brightness temperature shifted by 0.2 degrees C; with 10 degrees C variations in ambient temperature the shift was 0.15 degrees C. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Portable microwave radiometer for wearable devices
    Vesnin, Sergey G.
    Sedankin, Mikhail K.
    Ovchinnikov, Lev M.
    Gudkov, Alexander G.
    Leushin, Vitaly Yu
    Sidorov, Igor A.
    Goryanin, Igor I.
    [J]. NEXO REVISTA CIENTIFICA, 2021, 34 (04): : 1431 - 1447
  • [2] A portable microwave radiometer for proximal measurement of soil permittivity
    Gudkov, Alexander G.
    Agasieva, Svetlana V.
    Sidorov, Igor A.
    Khokhlov, Nikolay F.
    Chernikov, Alexander S.
    Vagapov, Yuriy
    [J]. Computers and Electronics in Agriculture, 2022, 198
  • [3] A portable microwave radiometer for proximal measurement of soil permittivity
    Gudkov, Alexander G.
    Agasieva, Svetlana, V
    Sidorov, Igor A.
    Khokhlov, Nikolay F.
    Chernikov, Alexander S.
    Vagapov, Yuriy
    [J]. COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2022, 198
  • [4] Microwave Devices for Wearable Sensors and IoT
    Costanzo, Alessandra
    Augello, Elisa
    Battistini, Giulia
    Benassi, Francesca
    Masotti, Diego
    Paolini, Giacomo
    [J]. SENSORS, 2023, 23 (09)
  • [5] Portable and Wearable Device for Microwave Head Diagnostic Systems
    Saied, Imran
    Hussainy, Syed Ali Akbar
    [J]. 2019 IEEE HEALTHCARE INNOVATIONS AND POINT OF CARE TECHNOLOGIES (HI-POCT), 2019, : 45 - 48
  • [6] Wearable and Portable Devices in Sport Biomechanics and Training Science
    Jaen-Carrillo, Diego
    Perez-Castilla, Alejandro
    Garcia-Pinillos, Felipe
    [J]. SENSORS, 2024, 24 (14)
  • [7] Wearable Triboelectric Generator for Powering the Portable Electronic Devices
    Cui, Nuanyang
    Liu, Jinmei
    Gu, Long
    Bai, Suo
    Chen, Xiaobo
    Qin, Yong
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (33) : 18225 - 18230
  • [8] Using multiple portable/wearable devices for enhanced misalignment estimation in portable navigation
    Medhat Omr
    Jacques Georgy
    Aboelmagd Noureldin
    [J]. GPS Solutions, 2017, 21 : 393 - 404
  • [9] Using multiple portable/wearable devices for enhanced misalignment estimation in portable navigation
    Omr, Medhat
    Georgy, Jacques
    Noureldin, Aboelmagd
    [J]. GPS SOLUTIONS, 2017, 21 (02) : 393 - 404
  • [10] Context-based storage management for wearable and portable devices
    Karypidis, A
    Lalis, S
    [J]. SYSTEMS ASPECTS IN ORGANIC AND PERVASIVE COMPUTING - ARCS 2005, PROCEEDINGS, 2005, 3432 : 236 - 248