Action potentials recorded with patch-clamp amplifiers: Are they genuine?

被引:105
|
作者
Magistretti, J
Mantegazza, M
Guatteo, E
Wanke, E
机构
[1] UNIV MILAN,DEPT GEN PHYSIOL & BIOCHEM,LAB ELECTROPHYSIOL,I-20133 MILAN,ITALY
[2] NATL NEUROL INST C BESTA,DEPT EXPT NEUROPHYSIOL,I-20133 MILAN,ITALY
关键词
D O I
10.1016/S0166-2236(96)40004-2
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A growing number of experimental studies have used patch-clamp amplifiers (PCAs) in the current-clamp (CC) mode to investigate classical excitability. In this paper we show that the measurements obtained in this way are affected by errors due to the electronic design of the PCA input section. We present experimental evidence of such errors, and demonstrate that they derive from PCA current absorption. Moreover, we propose a new PCA input-circuit configuration for the CC mode, which is suitable for accurately recording physiological voltage signals and is perfectly compatible with the standard voltage-clamp mode.
引用
收藏
页码:530 / 534
页数:5
相关论文
共 50 条
  • [1] Patch-clamp amplifiers on a chip
    Weerakoon, Pujitha
    Culurciello, Eugenio
    Yang, Youshan
    Santos-Sacchi, Joseph
    Kindlmann, Peter J.
    Sigworth, Fred J.
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2010, 192 (02) : 187 - 192
  • [2] Artifactual voltage response recorded from hair cells with patch-clamp amplifiers
    Masetto, S
    Weng, TX
    Valli, P
    Correia, MJ
    [J]. NEUROREPORT, 1999, 10 (09) : 1837 - 1841
  • [3] Patch-Clamp Recordings of Action Potentials From Human Atrial Myocytes: Optimization Through Dynamic Clamp
    Verkerk, Arie O.
    Marchal, Gerard A.
    Zegers, Jan G.
    Kawasaki, Makiri
    Driessen, Antoine H. G.
    Remme, Carol Ann
    de Groot, Joris R.
    Wilders, Ronald
    [J]. FRONTIERS IN PHARMACOLOGY, 2021, 12
  • [4] Sperm Patch-Clamp
    Lishko, Polina
    Clapham, David E.
    Navarro, Betsy
    Kirichok, Yuriy
    [J]. CILIA, PT B, 2013, 525 : 59 - 83
  • [5] THE PATCH-CLAMP TECHNIQUE
    LIEM, LK
    SIMARD, JM
    SONG, YM
    TEWARI, K
    [J]. NEUROSURGERY, 1995, 36 (02) : 382 - 392
  • [6] Patch-clamp techniques
    Teulon, J
    [J]. M S-MEDECINE SCIENCES, 2004, 20 (05): : 550 - 550
  • [7] Virtual neurophysiology laboratories for life science education: action potentials and voltage-/patch-clamp recordings
    Aubin Tchaptchet
    Horst Schneider
    Hans A Braun
    [J]. BMC Neuroscience, 14 (Suppl 1)
  • [8] PATCH-CLAMP STUDY OF THE IONIC CURRENTS UNDERLYING ACTION-POTENTIALS IN CULTURED FROG PITUITARY MELANOTROPHS
    LOUISET, E
    CAZIN, L
    LAMACZ, M
    TONON, MC
    VAUDRY, H
    [J]. NEUROENDOCRINOLOGY, 1988, 48 (05) : 507 - 515
  • [9] Modalities of distortion of physiological voltage signals by patch-clamp amplifiers: A modeling study
    Magistretti, J
    Mantegazza, M
    de Curtis, M
    Wanke, E
    [J]. BIOPHYSICAL JOURNAL, 1998, 74 (02) : 831 - 842
  • [10] An integrated patch-clamp amplifier for high-throughput planar patch-clamp systems
    Weerakoon, Pujitha
    Culurciello, Eugenio
    Klemic, Kate
    Sigworth, Fred J.
    [J]. PROCEEDINGS OF 2008 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-10, 2008, : 1808 - +