Multi-parameter measurement sensor based on no-core fiber

被引:5
|
作者
Sun Jia-Cheng [1 ]
Wang Ting-Ting [1 ]
Dai Yang [1 ]
Chang Jian-Hua [1 ]
Ke Wei [2 ,3 ]
机构
[1] Nanjing Univ Informat Sci & Technol, Sch Elect & Informat Engn, Nanjing 210044, Peoples R China
[2] Nanjing Normal Univ, Key Lab Optoelect Technol Jiangsu Prov, Nanjing 210023, Peoples R China
[3] Ctr Collaborat Innovat Geog Informat Resource Dev, Nanjing 210023, Peoples R China
基金
中国国家自然科学基金;
关键词
Mach-Zehnder sensor; core diameter mismatch; refractive index and temperature; simultaneous measurement;
D O I
10.7498/aps.70.20201474
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Aiming at the phenomenon of single measurement parameters and low sensitivity of most Mach-Zehnder sensors based on fiber core mismatch, in this paper we design and build a Mach-Zehnder sensor based on single-mode-no-core-single-mode-no-core-single-mode fiber structure, which can be used to measure refractive index and temperature simultaneously. In this sensor, two no-core optical fiber serve as input and output couplers, the intermediate single-mode is used as a sensing arm. Using finite element simulation and theoretical analysis, the optimal length of the coupler and the sensing arm are determined to be 15 mm. High-order modes excited by no-core optical fiber propagate through the cladding of single-mode fiber, which is affected by the ambient refractive index and temperature because of the influence of the evanescent filed. Trough of different interference orders of transmission spectrum is selected as a research object to realize the simultaneous measurement of refractive index and temperature by using sensitivity coefficient matrix. After the further Fourier transform of the transmission spectrum, the frequency of the main mode that interferes with the fundamental mode is analyzed from the spectrogram to be 0.00098 nm(-1). Because of the influence of temperature on the refractive index of water during temperature sensitivity measurement, temperature sensitivity formula and water temperature coefficient are introduced to perform temperature compensation to eliminate the cross sensitivity. In this paper, the 10 mm and 15 mm sensing arms are selected for refractive index comparison experiment, and the temperature experiment is focused on the sensing arm with an optimal length of 15 mm. The experimental results show that the transmission spectrum is blue-shifted with the increase of refractive index in a refractive index range of 1.333-1.397, and the transmission spectrum is red-shifted with the increase of temperature in a temperature range from 30 degrees C to 70 degrees C The refractive index and temperature sensitivity of the interference valley near 1545 nm are -153.89 nm/RIU and 0.166 nm/degrees C, respectively; the refractive index and temperature sensitivity of the interference valley near 1570 nm are -202.74 nm/RIU and 0.183 nm/degrees C, respectively. The experimental results are consistent with the theoretical analyses. Compared with the sensor of the same type, this sensor can still maintain high sensitivity while achieving simultaneous measurement of refractive index and temperature, and has a simple structure, which has a good application prospect in biomedical and other aspects.
引用
收藏
页数:8
相关论文
共 23 条
  • [1] Mach-Zehnder interferometer based on fiber taper and fiber core mismatch for humidity sensing
    Cheng Jun-Ni
    [J]. ACTA PHYSICA SINICA, 2018, 67 (02)
  • [2] All-fiber Mach-Zehnder type interferometers formed in photonic crystal fiber
    Choi, Hae Young
    Kim, Myoung Jin
    Lee, Byeong Ha
    [J]. OPTICS EXPRESS, 2007, 15 (09): : 5711 - 5720
  • [3] Simultaneous measurement of refractive index and temperature using a Mach-Zehnder interferometer with forward core-cladding-core recoupling
    Jiao, Tao
    Meng, Hongyun
    Deng, Shuying
    Liu, Shuai
    Wang, Xianjun
    Wei, Zhongchao
    Wang, Faqiang
    Tan, Chunhua
    Huang, Xuguang
    [J]. OPTICS AND LASER TECHNOLOGY, 2019, 111 : 612 - 615
  • [4] In-fiber Mach-Zehnder interferometer based on fiber core etched air-bubble and core diameter mismatch for liquid refractive index sensing
    Li Hui-Dong
    Fu Hai-Wei
    Shao Min
    Zhao Na
    Qiao Xue-Guang
    Liu Ying-Gang
    Li Yan
    Yan Xu
    [J]. ACTA PHYSICA SINICA, 2013, 62 (21)
  • [5] Properties of Hydrogen Sulfide Gas Sensor Based on No-Core-Multimode-No-Core Fiber Structure
    Liu Min
    Feng Dejiu
    Feng Wenlin
    [J]. ACTA OPTICA SINICA, 2019, 39 (10)
  • [6] A novel optical fiber magnetic field sensor based on Mach-Zehnder interferometer integrated with magnetic fluid
    Luo, Yan
    Lei, Xueqin
    Shi, Fuquan
    Peng, Baojin
    [J]. OPTIK, 2018, 174 : 252 - 258
  • [7] Temperature Response Properties of Macrobending Loss of Single-mode Fiber
    Peng Xing-ling
    Cha Ying-peng
    Zhang Hua
    Li Yu-long
    [J]. ACTA PHOTONICA SINICA, 2018, 47 (11)
  • [8] Magnetic field sensing based on magnetic-fluid-clad no-core single-mode no-core fiber structure
    Pu, Sheng-Li
    Tang, Jia-Li
    Liu, Zhi-Heng
    Luo, Long-Feng
    [J]. Guangzi Xuebao/Acta Photonica Sinica, 2015, 44 (12):
  • [9] A Review of Vehicular Pollution and Control Measures in India
    Rastogi, Aayush
    Rajan, Albert V.
    Mukherjee, Mainak
    [J]. ADVANCES IN HEALTH AND ENVIRONMENT SAFETY, 2018, : 237 - 245
  • [10] Highly sensitive surface plasmon resonance based fiber optic pH sensor utilizing rGO-Pani nanocomposite prepared by in situ method
    Semwal, Vivek
    Gupta, Banshi D.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2019, 283 : 632 - 642