Intraocular Pressure-dependent Corneal Elasticity Measurement Using High-frequency Ultrasound

被引:11
|
作者
Osapoetra, Laurentius O. [1 ]
Watson, Dan M. [1 ]
McAleavey, Stephen A. [2 ]
机构
[1] Univ Rochester, Dept Phys & Astron, Rochester, NY 14627 USA
[2] Univ Rochester, Dept Biomed Engn, Rochester, NY 14627 USA
关键词
corneal biomechanics; high-frequency ultrasound; high-resolution elastography; Lamb wave; IOP; MAGNETIC-RESONANCE ELASTOGRAPHY; OPTICAL COHERENCE ELASTOGRAPHY; COLLAGEN CROSS-LINKING; BIOMECHANICAL PROPERTIES; NONINVASIVE MEASUREMENT; WAVE SPEED; TISSUE; RESOLUTION; LOCATION; STRENGTH;
D O I
10.1177/0161734619858386
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Measurement of corneal biomechanical properties can aid in predicting corneal responses to diseases and surgeries. For delineation of spatially resolved distribution of corneal elasticity, high-resolution elastography system is required. In this study, we demonstrate a high-resolution elastography system using high-frequency ultrasound for ex-vivo measurement of intraocular pressure (IOP)-dependent corneal wave speed. Tone bursts of 500 Hz vibrations were generated on the corneal surface using an electromagnetic shaker. A 35-MHz single-element transducer was used to track the resulting anti-symmetrical Lamb wave in the cornea. We acquired spatially resolved wave speed images of the cornea at IOPs of 7, 11, 15, 18, 22, and 29 mmHg. The IOP dependence of corneal wave speed is apparent from these images. Statistical analysis of measured wave speed as a function of IOP revealed a linear relation between wave speed and IOP c(s) = 0.37 + 0.22 x IOP, with the coefficient of determination R-2 = 0.86. We also observed depth-dependent variations of wave speed in the cornea, decreasing from anterior toward posterior. This depth dependence is more pronounced at higher IOP values. This study demonstrates the potential of high-frequency ultrasound elastography in the characterization of spatially resolved corneal biomechanical properties.
引用
收藏
页码:251 / 270
页数:20
相关论文
共 50 条
  • [1] HIGH-FREQUENCY ULTRASOUND MEASUREMENT OF THE THICKNESS OF THE CORNEAL EPITHELIUM
    REINSTEIN, DZ
    SILVERMAN, RH
    COLEMAN, DJ
    [J]. REFRACTIVE AND CORNEAL SURGERY, 1993, 9 (05): : 385 - 387
  • [2] USING HIGH-FREQUENCY ULTRASOUND TO CHARACTERIZE INTRAOCULAR FOREIGN-BODIES
    NOUBYMAHMOUD, G
    SILVERMAN, RH
    COLEMAN, DJ
    [J]. OPHTHALMIC SURGERY AND LASERS, 1993, 24 (02): : 94 - 99
  • [3] eNOS, a Pressure-Dependent Regulator of Intraocular Pressure
    Stamer, W. Daniel
    Lei, Yuan
    Boussommier-Calleja, Alexandra
    Overby, Darryl R.
    Ethier, C. Ross
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (13) : 9438 - 9444
  • [4] HIGH-FREQUENCY ULTRASOUND BIOMICROSCOPY (UBM) VERSUS ULTRASOUND AND OPTICAL PACHYMETRY FOR THE MEASUREMENT OF CORNEAL THICKNESS
    ROBINO, X
    PIERRO, LM
    BRANCATO, R
    RESTI, AG
    MURAGLIA, M
    ZANGANELLI, E
    CARONES, F
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S37 - S37
  • [5] ANALYSIS OF BOREHOLE STRESSES USING PRESSURE-DEPENDENT, LINEAR ELASTICITY
    SANTARELLI, FJ
    BROWN, ET
    MAURY, V
    [J]. INTERNATIONAL JOURNAL OF ROCK MECHANICS AND MINING SCIENCES & GEOMECHANICS ABSTRACTS, 1986, 23 (06) : 445 - 449
  • [6] Role of corneal elasticity in damping of intraocular pressure
    Johnson, C. Starck
    Mian, Shahzad I.
    Moroi, Sayoko
    Epstein, David
    Izatt, Joseph
    Afshari, Natalie A.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (06) : 2540 - 2544
  • [7] MEASUREMENT OF THE DEPTH OF KERATOTOMY INCISIONS USING HIGH-FREQUENCY ULTRASOUND
    BELMONT, SC
    MULLER, JW
    SILVERMAN, RH
    REINSTEIN, DZ
    ASLANIDES, IM
    COLEMAN, DJ
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 2017 - 2017
  • [8] Measurement of amniochorionic membrane thickness using high-frequency ultrasound
    Frigo, P
    Lang, C
    Golaszewski, T
    Gruber, D
    Berger, A
    Ulrich, R
    Eppel, W
    Huber, J
    [J]. PRENATAL DIAGNOSIS, 1996, 16 (04) : 313 - 317
  • [9] Measurement of amniochorionic membrane thickness using high-frequency ultrasound
    Frigo, P
    Lang, C
    Golaszewski, T
    Sator, M
    Ullrich, R
    Eppel, W
    Schurz, B
    [J]. ULTRASCHALL IN DER MEDIZIN, 1996, 17 (04): : 167 - 170
  • [10] High-Frequency Measurement of Ultrasound Using Flexural Ultrasonic Transducers
    Feeney, Andrew
    Kang, Lei
    Dixon, Steve
    [J]. IEEE SENSORS JOURNAL, 2018, 18 (13) : 5238 - 5244