Microparticles and Nanoparticles Delivered in Intravenous Saline and in an Intravenous Solution of a Therapeutic Antibody Product

被引:43
|
作者
Pardeshi, Neha N. [1 ]
Qi, Wei [2 ]
Dahl, Kevin [2 ]
Caplan, Liron [3 ,4 ]
Carpenter, John F. [1 ]
机构
[1] Univ Colorado, Sch Pharm, Dept Pharmaceut Sci, Anschutz Med Campus, Aurora, CO 80045 USA
[2] Malvern Instruments, Columbia, MD 21046 USA
[3] Univ Colorado, Denver Vet Affairs Hosp, Rheumatol Sect, Aurora, CO 80045 USA
[4] Univ Colorado, Sch Med, Aurora, CO 80045 USA
关键词
protein aggregation; microparticles; nanoparticles; IgG antibody; protein delivery; adsorption; particle size; POLYVINYL-CHLORIDE BAGS; MONOCLONAL-ANTIBODY; PROTEIN AGGREGATION; GROWTH-HORMONE; FACTOR-VIII; PARTICLES; STABILITY; INFUSION; MICE; IMMUNOGENICITY;
D O I
10.1016/j.xphs.2016.09.028
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Intravenous ( IV) infusion is used for administration of a large proportion of biologic therapeutics, including most monoclonal antibody products. In this study, we determined the subvisible particle levels in IV solutions and after the solutions were processed with an IV administration setup that mimicked the typical clinical method of administration. IV saline in bags manufactured by both Hospira and Baxter contained 1600-8000 microparticles/mL and 4-73 x 10(6) nanoparticles/mL in solution. When IV immunoglobulin was diluted into the IV saline, 3700-23,000 microparticles/mL and 18-240 x 10(6) nanoparticles/mL were detected. During processing of the solution through the IV system, in-line filters removed most microparticles. However, there were still 1-21 x 10(6) nanoparticles/mL in IV saline and 7-83 x 10(6) nanoparticles/mL in IV immunoglobulin diluted in saline. Finally, in samples processed through in-line filters, we found relatively large microparticles ( 20-60 mm) that were composed of protein or polycarbonate. These particles resulted from shedding of polycarbonate and sloughing off of protein films downstream from the filter membrane. Overall, the results document that even with in-line filters in place, high levels of subvisible particles are delivered to patients and there is a need for improved, more effective filters and IV solutions with lower particle levels. (C) 2017 American Pharmacists Association (R). Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:511 / 520
页数:10
相关论文
共 50 条