Surgically induced astigmatism after posterior chamber phakic intraocular lens implantation

被引:22
|
作者
Kamiya, K. [1 ]
Shimizu, K. [1 ]
Aizawa, D. [1 ]
Igarashi, A. [1 ]
Komatsu, M. [2 ]
机构
[1] Kitasato Univ, Dept Ophthalmol, Sch Med, Kanagawa 2288555, Japan
[2] Sanno Hosp, Dept Ophthalmol, Tokyo, Japan
关键词
HIGH MYOPIC ASTIGMATISM; ADMINISTRATION CLINICAL-TRIAL; TEMPORAL CLEAR CORNEAL; COLLAMER LENS; CONTACT-LENS; FOLLOW-UP; MODERATE; INCISIONS; SURGERY; SHAPE;
D O I
10.1136/bjo.2009.160044
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To assess astigmatism induced after phakic intraocular lens (Visian ICL, STAAR Surgical) implantation. Methods: Seventy-three eyes of 47 patients undergoing ICL implantation through a horizontal 3.0 mm clear corneal incision were retrospectively examined. The amount of corneal astigmatism before and 3 months after surgery using an automated keratometer (ARK-700A, Nidek) and corneal topography (ATRAS995, Carl Zeiss Meditec) were quantitatively investigated. The surgically induced astigmatism was assessed by vector analysis using the Holladay-Cravy-Koch formula. Results: The corneal astigmatism was significantly increased from 1.10 (0.51) dioptres (D) to 1.44 (0.57) D using the keratometer (Wilcoxon signed-rank test, p<0.001). It was also significantly increased from 1.16 (0.53) D to 1.45 (0.57) D using corneal topography (p<0.001). On the other hand, the manifest astigmatism was significantly decreased from 0.93 (0.60) D to 0.72 (0.58) D (p<0.001). The surgically induced astigmatism was 0.45 (0.26) D at an axis of 93.3 degrees using the keratometer and 0.49 (0.26) D at an axis of 98.0 degrees using corneal topography. Conclusions: ICL implantation induces corneal astigmatism through a with-the-rule astigmatic shift of approximately 0.5 D, which was small but not negligible for candidates for refractive surgery.
引用
收藏
页码:1648 / 1651
页数:4
相关论文
共 50 条
  • [1] Successful toric intraocular lens implantation in a patient with induced cataract and astigmatism after posterior chamber toric phakic intraocular lens implantation: a case report
    Kazutaka Kamiya
    Akio Nakamura
    Hideyuki Miyake
    Hiroyuki Nishimoto
    Kimiya Shimizu
    Journal of Medical Case Reports, 6 (1)
  • [2] Lens opacities after posterior chamber phakic intraocular lens implantation
    Sánchez-Galeana, CA
    Smith, RJ
    Sanders, DR
    Rodríguez, FX
    Litwak, S
    Montes, M
    Chayet, AS
    OPHTHALMOLOGY, 2003, 110 (04) : 781 - 785
  • [3] Cataract formation after posterior chamber phakic intraocular lens implantation
    Trindade, F
    Pereira, F
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (12): : 1661 - 1663
  • [4] Refractory intraocular pressure increase after phakic posterior chamber intraocular lens implantation
    Sánchez-Galeana, CA
    Zadok, D
    Montes, M
    Cortés, MA
    Chayet, AS
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 134 (01) : 121 - 123
  • [5] Prediction of anterior chamber volume after implantation of posterior chamber phakic intraocular lens
    Takagi, Yuki
    Kojima, Takashi
    Nishida, Tomoya
    Nakamura, Tomoaki
    Ichikawa, Kazuo
    PLOS ONE, 2020, 15 (11):
  • [6] Pupil Dynamics Induced by Light Reflex After Posterior Chamber Phakic Intraocular Lens Implantation
    Totsuka, Kazuko
    Ishikawa, Hitoshi
    Kamiya, Kazutaka
    Shoji, Nobuyuki
    Shimizu, Kimiya
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (10) : 704 - +
  • [7] Posterior chamber phakic intraocular lens implantation after laser in situ keratomileusis
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Igarashi, Akihito
    Kitazawa, Yoshihiro
    Kojima, Takashi
    Nakamura, Tomoaki
    Ichikawa, Kazuo
    Fukuoka, Sachiko
    Fujimoto, Kahoko
    EYE AND VISION, 2022, 9 (01)
  • [8] Visual quality after posterior chamber phakic intraocular lens implantation in keratoconus
    Kurian, Mathew
    Nagappa, Somshekar
    Bhagali, Ridhima
    Shetty, Rohit
    Shetty, Bhujang K.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06): : 1050 - 1057
  • [9] Evaluation of pupil diameter after posterior chamber phakic intraocular lens implantation
    K Kamiya
    K Shimizu
    A Igarashi
    H Ishikawa
    Eye, 2010, 24 : 588 - 594
  • [10] Evaluation of pupil diameter after posterior chamber phakic intraocular lens implantation
    Kamiya, K.
    Shimizu, K.
    Igarashi, A.
    Ishikawa, H.
    EYE, 2010, 24 (04) : 588 - 594