Measurements of Orbital Volume Change Using Computed Tomography in Isolated Orbital Blowout Fractures

被引:0
|
作者
Kwon, Jaehwan [1 ]
Barrera, Jose E. [1 ]
Jung, Tae-Young [2 ]
Most, Sam P. [1 ]
机构
[1] Stanford Univ, Dept Otolaryngol Head & Neck Surg, Div Facial Plast Surg & Reconstruct Surg, Stanford, CA 94305 USA
[2] Maryknoll Med Ctr, Dept Otolaryngol Head & Neck Surg, Pusan, South Korea
关键词
LATE ENOPHTHALMOS; FLOOR FRACTURES; PREDICTION; WALL;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: To measure the orbital volume of unilateral pure blowout fractures with computed tomography before and after surgery and to compare 3-dimensional (3-D) imaging systems. Methods: Twenty-four patients were evaluated with facial computed tomographic scans before and after surgery. Both the orbital volume and the displaced soft tissue volume were measured by 2 operators using 2 different 3-D software programs (Vitrea; Vital Images Inc, Minnetonka, Minnesota; and Dextroscope; Bracco AMT Inc, Princeton, NJ). Results: The mean (SD) normal orbital volumes calculated by Vitrea and Dextroscope were 25.5 (2.4) mL and 24.8 (3.0) mL, respectively. The average preoperative orbital volumes were 28.3 (2.3) mL and 27.6 (3.1) mL, while the postoperative volumes were 25.8 (2.5) mL and 24.9 (3.0) mL. Vitrea showed that the average volume of displaced orbital soft tissue was 2.8 (1.9) mL before surgery and that it was reduced to 0.3 (1.3) mL after surgery, while Dextroscope showed that the average displaced orbital soft tissue was 2.9 (1.4) mL before surgery and that it was reduced to 0.1 (1.2) mL after surgery. There was no statistical difference between the 3-D analysis programs. Conclusions: Consistent volume measurements can be obtained using different 3-D image analysis programs. Measuring preoperative and postoperative volume changes and postoperative reduction can ensure a good surgical result and thereby decrease the incidence of enophthalmos.
引用
收藏
页码:395 / 398
页数:4
相关论文
共 50 条
  • [1] ORBITAL BLOWOUT FRACTURES - THE PROGNOSTIC-SIGNIFICANCE OF COMPUTED-TOMOGRAPHY
    GILBARD, SM
    MAFEE, MF
    LAGOUROS, PA
    LANGER, BG
    OPHTHALMOLOGY, 1985, 92 (11) : 1523 - 1528
  • [2] Relationship of Pre-orbital and Orbital Volume to Blowout Fractures
    Sharifi, Emile
    Thao Phuong Le
    Howe, Katherine
    Mitsumori, Lee
    Jian-Amadi, Arash
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [3] The role of computed tomography (CT) in predicting diplopia in orbital blowout fractures (BOFs)
    Cellina M.
    Floridi C.
    Panzeri M.
    Giancarlo O.
    Emergency Radiology, 2018, 25 (1) : 13 - 19
  • [4] ORBITAL VOLUME MEASUREMENT IN THE MANAGEMENT OF PURE BLOWOUT FRACTURES OF THE ORBITAL FLOOR
    CHARTERIS, DG
    CHAN, CH
    WHITEHOUSE, RW
    NOBLE, JL
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1993, 77 (02) : 100 - 102
  • [5] Correlation of preoperative computed tomography and postoperative ocular motility in orbital blowout fractures
    Harris, GJ
    Garcia, GH
    Logani, SC
    Murphy, ML
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2000, 16 (03): : 179 - 187
  • [6] Bony realignment in surgically treated orbital blowout fractures based on computed tomography
    Park, Ji Woong
    Lee, Chaeyeon
    Woo, Kyung In
    Kim, Yoon-Duck
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [7] Evaluation of computer-based area and volume measurement from coronal computed tomography scans in isolated blowout fractures of the orbital floor
    Ploder, O
    Klug, C
    Voracek, M
    Burggasser, G
    Czerny, C
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 60 (11) : 1267 - 1272
  • [8] Isolated orbital blowout fractures: survey and review
    Courtney, DJ
    Thomas, S
    Whitfield, PH
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2000, 38 (05): : 496 - 503
  • [9] The validity and reliability of computed tomography orbital volume measurements
    Diaconu, Silviu C.
    Dreizin, David
    Uluer, Mehmet
    Mossop, Corey
    Grant, Michael P.
    Nam, Arthur J.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (09) : 1552 - 1557
  • [10] ORBITAL BLOWOUT FRACTURES
    KROLL, M
    WOLPER, J
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1967, 64 (06) : 1169 - &