Responses to Continuous Glucose Monitoring in Subjects with Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion or Multiple Daily Injections

被引:25
|
作者
Rodbard, David [1 ]
Jovanovic, Lois [2 ]
Garg, Satish K. [3 ]
机构
[1] Biomed Informat Consultants LLC, Potomac, MD 20854 USA
[2] Sansum Diabet Res Inst, Santa Barbara, CA USA
[3] Univ Colorado Denver, Barbara Davis Ctr Diabet, Aurora, CO USA
关键词
IMPROVED GLYCEMIC CONTROL; OXIDATIVE STRESS; VARIABILITY; QUALITY; FLUCTUATIONS; ACTIVATION; SENSOR; INDEX; BLOOD;
D O I
10.1089/dia.2009.0078
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: We compared changes in response to unmasking of continuous glucose monitoring (CGM) in subjects with type 1 diabetes who use multiple daily injections (MDI) or continuous subcutaneous insulin infusion (CSII). Research Design and Methods: Use of real-time CGM (DexCom [San Diego, CA] SEVEN(R)) was studied in 38 subjects using CSII and 26 using MDI. CGM output was masked during Week 1 and unmasked during Weeks 2 and 3. We evaluated changes in 16 criteria for quality of glycemic control and eight criteria for glycemic variability. Results: All 24 criteria showed highly statistically significant improvement when considered simultaneously (P < 0.000001). For subjects using CSII, 18 of 24 criteria improved significantly (nominal P < 0.05); for subjects using MDI, 16 of 24 criteria improved significantly (P < 0.05). Twelve of the comparisons remained significant (P < 0.05) after applying the overconservative Bonferroni correction for multiple comparisons. The percentage of glucose values within the range 80-140mg/dL increased by 19% and 17% relative to their control values (Week 1) for subjects using MDI and CSII, respectively. Mean glucose, overall SD (SDT), SD between daily means (SDdm), mean amplitude of glycemic excursion (MAGE), and mean of daily differences (MODD) improved significantly. Responses to CGM display were not significantly different between the MDI and CSII subject groups for any of the 24 criteria considered individually or in groups of eight, 16, or 24. Conclusion: CGM has similar effectiveness in subjects with type 1 diabetes using either CSII or MDI.
引用
收藏
页码:757 / 765
页数:9
相关论文
共 50 条
  • [1] Continuous subcutaneous insulin infusion versus multiple daily injections for type 1 diabetes
    Ross, Lindsey J.
    Neville, Kristen A.
    [J]. JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2019, 55 (06) : 718 - 722
  • [2] Use of Continuous Glucose Monitoring in Subjects With Type 1 Diabetes on Multiple Daily Injections Versus Continuous Subcutaneous Insulin Infusion Therapy A prospective 6-month study
    Garg, Satish K.
    Voelmle, Mary K.
    Beatson, Christie R.
    Miller, Hayley A.
    Crew, Lauren B.
    Freson, Brandon J.
    Hazenfield, Rachel M.
    [J]. DIABETES CARE, 2011, 34 (03) : 574 - 579
  • [3] Continuous subcutaneous infusion versus multiple daily injections of insulin for type 1 diabetes in pregnancy
    Fisher, Stephanie A.
    Xu, Nicole Y.
    Huang, Jingtong
    Dubord, Ashley
    Beestrum, Molly
    Niznik, Charlotte M.
    Yeung, Andrea M.
    Nguyen, Kevin
    Klonoff, David C.
    Yee, Lynn M.
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 228 (01) : S743 - S744
  • [4] Continuous subcutaneous insulin infusion versus multiple daily injections in children with type 1 diabetes
    Weintrob, N
    Benzaquen, H
    Shalitin, S
    Fayman, G
    Galatzer, A
    Dickerman, Z
    Phillip, M
    [J]. DIABETOLOGIA, 2001, 44 : A26 - A26
  • [5] A qualitative comparison between multiple daily injections and continuous subcutaneous insulin infusion using a continuous glucose monitoring system
    Javor, ED
    Ilic, S
    Lee, SW
    [J]. DIABETES, 2001, 50 : A438 - A438
  • [6] The efficacy of continuous subcutaneous insulin infusion and multiple daily injections of insulin in pregnant women with type 1 diabetes
    Hebda-Szydlo, A.
    Cyganek, K.
    Malecki, M. T.
    Trznadel-Morawska, I.
    Katra, B.
    Klupa, T.
    Kaim, I.
    Reron, A.
    Sicradzki, J.
    [J]. DIABETOLOGIA, 2008, 51 : S456 - S457
  • [7] Multiple daily injections of insulin versus continuous subcutaneous insulin infusion for pregnant women with type 1 diabetes
    Wender-Ozegowska, Ewa
    Zawiejska, Agnieszka
    Ozegowska, Katarzyna
    Wroblewska-Seniuk, Katarzyna
    Iciek, Rafal
    Mantaj, Urszula
    Olejniczak, Danuta
    Brazert, Jacek
    [J]. AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2013, 53 (02): : 130 - 135
  • [8] Continuous Subcutaneous Insulin Infusion Versus Multiple Daily Injections in Pregnant Women with Type 1 Diabetes
    Gonzalez-Romero, Stella
    Gonzalez-Molero, Inmaculada
    Fernandez-Abellan, Micaela
    Dominguez-Lopez, Marta E.
    Ruiz-de-Adana, Soledad
    Olveira, Gabriel
    Soriguer, Federico
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2010, 12 (04) : 263 - 269
  • [9] Transition from multiple daily injections to continuous subcutaneous insulin infusion in type 1 diabetes mellitus
    Conrad, SC
    McGrath, MT
    Gitelman, SE
    [J]. JOURNAL OF PEDIATRICS, 2002, 140 (02): : 235 - 240
  • [10] The impact of continuous subcutaneous insulin infusion and multiple daily injections of insulin on glucose variability in older adults with type 2 diabetes
    Johnson, Susan L.
    McEwen, Laura N.
    Newton, Christopher A.
    Martin, Catherine L.
    Raskin, Philip
    Halter, Jeffrey B.
    Herman, William H.
    [J]. JOURNAL OF DIABETES AND ITS COMPLICATIONS, 2011, 25 (04) : 211 - 215