The MISR radiometric calibration process

被引:42
|
作者
Bruegge, Carol J.
Diner, David J.
Kahn, Ralph A.
Chrien, Nadine
Helmlinger, Mark C.
Gaitley, Barbara J.
Abdou, Wedad A.
机构
[1] CALTECH, Jet Prop Lab, Pasadena, CA 91125 USA
[2] Instrument Design Engn Associates, Brea, CA USA
[3] Northrop Grumman Space Technol, El Segundo, CA USA
关键词
radiometric calibration; MISR;
D O I
10.1016/j.rse.2006.07.024
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
One important objective of the Multi-angle Imaging SpectroRadiometer (MISR) is retrieving global aerosol loading and microphysical properties. Accuracy depends on many factors, including the availability of a complete catalog of particle types with their associated size distributions, shapes, single-scattefing albedos, vertical profiles, and spectral radiative characteristics. Co-equal to this need is the availability of a well-designed, well-characterized instrument, with a calibration that is maintained post-launch. This allows accurate radiance and retrieval products to be made, adjusting for instrument changes. MISR performance has been intensively studied throughout the design, pre-flight, and post-launch mission phases. To establish the absolute radiometric scale, annual vicarious calibration (VC) exercises have been conducted. In addition, an on-board-calibrator (OBC) allows more frequent testing of camera degradations. Together, the VC and OBC processes have allowed MISR to achieve an absolute calibration uncertainty of 4% or better (la confidence level) for bright land targets. Additional fine-tunings have been made following analysis of lunar-view campaign data, and from a statistical analysis of Earth observations. These studies led to slight camera-to-camera adjustments, which are important in improving the aerosol retrieval process. Validation of the response at the lower end of the dynamic range has also been accomplished using a dark-water study. With these studies complete, MISR calibration is now in an operational mode, and data users can be assured the resulting data products are stable with time. Such records meet the needs of a program designed to support climate change and provide long-term monitoring of the Earth's atmosphere and radiative fluxes. (c) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:2 / 11
页数:10
相关论文
共 50 条
  • [1] The absolute radiometric calibration of Terra imaging sensors: MODIS, MISR, and ASTER
    Czapla-Myers, Jeffrey
    Thome, Kurtis
    Anderson, Nikolaus
    Biggar, Stuart
    [J]. EARTH OBSERVING SYSTEMS XIX, 2014, 9218
  • [2] The MISR calibration program
    Bruegge, CJ
    Diner, DJ
    Duval, VG
    [J]. JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 1996, 13 (02) : 286 - 299
  • [3] MISR calibration program
    [J]. J Atmos Oceanic Technol, 2 (286-299):
  • [4] Refinements to MISR's radiometric calibration and implications for establishing a climate-quality aerosol observing system
    Diner, DJ
    Kahn, RA
    Bruegge, CJ
    Martonchik, JV
    Abdou, WA
    Gaitley, BJ
    Helmlinger, MC
    Kalashnikova, OV
    Li, WH
    [J]. PASSIVE OPTICAL REMOTE SENSING OF THE ATMOSPHERE AND CLOUDS IV, 2004, 5652 : 57 - 65
  • [5] CALIBRATION OF A RADIOMETRIC DENSITY MEASURING DEVICE FOR THE BOILING PROCESS
    HEMPELMANN, R
    AUSTMEYER, KE
    [J]. ZUCKERINDUSTRIE, 1987, 112 (08): : 695 - 698
  • [6] Distortion calibration of the MISR linear detectors
    Korechoff, R
    Kirby, D
    Hochberg, E
    Sepulveda, C
    Jovanovic, V
    [J]. EARTH OBSERVING SYSTEM, 1996, 2820 : 174 - 183
  • [7] MISR radiometric uncertainty analyses and their utilization within geophysical retrievals
    Bruegge, CJ
    Chrien, NL
    Diner, DJ
    Kahn, RA
    Martonchik, JV
    [J]. METROLOGIA, 1998, 35 (04) : 571 - 579
  • [8] Radiometric calibration of Landsat
    Thome, K
    Markham, B
    Barker, J
    Slater, P
    Biggar, S
    [J]. PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 1997, 63 (07): : 853 - 858
  • [9] Radiometric Calibration for AgCam
    Olsen, Doug
    Dou, Changyong
    Zhang, Xiaodong
    Hu, Lianbo
    Kim, Hojin
    Hildum, Edward
    [J]. REMOTE SENSING, 2010, 2 (02) : 464 - 477
  • [10] Radiometric calibration of MERIS
    Delwart, S
    Bourg, L
    [J]. SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES VIII, 2004, 5570 : 372 - 380