Direct determination of praziquantel in pharmaceutical formulations and human plasma by cathodic adsorptive stripping differential-pulse voltammetry

被引:15
|
作者
Ghoneim, MM [1 ]
Mabrouk, MM
Tawfik, A
机构
[1] Tanta Univ, Fac Sci, Dept Chem, Tanta 31527, Egypt
[2] Tanta Univ, Fac Pharm, Dept Analyt Chem, Tanta 31527, Egypt
关键词
praziquantel; polarography; adsorptive stripping differential-pulse voltammetry; determination in pharmaceutical forms and human plasma;
D O I
10.1016/S0731-7085(02)00457-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The polarographic and cyclic voltammetric behaviour of praziquantel was studied in B.R. buffers of different pH values. Contradictory to that mentioned in a previously published work, praziquantel is an electro-active compound. Its polarogram. exhibited a single 2-electron irreversible reduction wave in B.R. buffer of pH 5, the wave height decreased on the increase of pH till it disappeared in solution of pH > 7. This wave was attributed to the reduction of the C=O double bond. The quantitative trace determination of bulk praziquantel was studied at a hanging mercury drop electrode by cathodic adsorptive stripping differential-pulse voltammetry. A fully validated sensitive procedure based on controlled adsorptive accumulation of the drug onto a HMDE was developed for its direct determination without derivatization. Accumulation of praziquantel was found to be optimized in 0.1 M Na2SO4 solution as supporting electrolyte under the following conditions: accumulation potential, -1.2 V (vs. Ag/AgCl/KCls); accumulation time, 30 s; scan rate, 10 mV/s and pulse height 100 mV. The proposed procedure was applied successfully for determination of praziquantel in its pharmaceutical formulations and human plasma. The mean recoveries of the drug were 98.85-99.42% and 99.12-100.47% with RSD of 0.49-0.95% and 0.45-0.52% in pharmaceutical formulations and human plasma, respectively. Limits of detection and quantitation. of 1.14 x 10(-9) and 3.80 x 10(-9) M praziquantel, respectively, were achieved. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1311 / 1318
页数:8
相关论文
共 50 条
  • [1] Determination of the antibacterial enrofloxacin by differential-pulse adsorptive stripping voltammetry
    Navalón, A
    Blanc, R
    Reyes, L
    Navas, N
    Vílchez, JL
    [J]. ANALYTICA CHIMICA ACTA, 2002, 454 (01) : 83 - 91
  • [2] Determination of the antibacterial trovafloxacin by differential-pulse adsorptive stripping voltammetry
    Vílchez, JL
    Taoufiki, J
    Araujo, L
    Navalón, A
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (03) : 465 - 471
  • [3] COBALT IN DUTCH MILK POWDER - DETERMINATION BY DIFFERENTIAL-PULSE ADSORPTIVE CATHODIC-STRIPPING VOLTAMMETRY
    KOOPS, J
    KLOMP, H
    [J]. NETHERLANDS MILK AND DAIRY JOURNAL, 1991, 45 (02): : 127 - 138
  • [4] DIFFERENTIAL-PULSE ADSORPTIVE STRIPPING VOLTAMMETRY OF CHLORHEXIDINE
    GRATTERI, P
    PINZAUTI, S
    LAPORTA, E
    PAPESCHI, G
    CAVRINI, V
    SANTONI, G
    [J]. ANALYST, 1991, 116 (07) : 723 - 725
  • [5] Indirect determination of praziquantel in human serum by cathodic adsorptive stripping voltammetry
    Radi, A
    Hassanein, AM
    [J]. CHEMIA ANALITYCZNA, 2001, 46 (04): : 561 - 567
  • [6] Determination of total arsenic in soils by differential-pulse cathodic stripping voltammetry
    Eguiarte, I
    Alonso, RM
    Jimenez, RM
    [J]. ANALYST, 1996, 121 (12) : 1835 - 1838
  • [7] Polarographic behaviour of loratadine and its direct determination in pharmaceutical formulation and human plasma by cathodic adsorptive stripping voltammetry
    Ghoneim, MM
    Mabrouk, MM
    Hassanein, AM
    Tawfik, A
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (5-6) : 933 - 939
  • [8] DETERMINATION OF NANOMOLAR LEVELS OF GUANINE BY DIFFERENTIAL-PULSE ADSORPTIVE CATHODIC STRIPPING VOLTAMMETRY OF ITS COPPER(II) COMPLEX
    SHUBIETAH, RM
    ABUZUHRI, AZ
    FOGG, AG
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (11): : 754 - 757
  • [9] DETERMINATION OF CEFTRIAXONE IN BIOLOGICAL-MATERIAL BY DIFFERENTIAL-PULSE ADSORPTIVE STRIPPING VOLTAMMETRY
    ALTINOZ, S
    TEMIZER, A
    BEKSAC, S
    [J]. ANALYST, 1990, 115 (06) : 873 - 874
  • [10] Determination of selenium in natural waters by adsorptive differential pulse cathodic stripping voltammetry
    Ashournia, Mehdi
    Aliakbar, Alireza
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2009, 168 (01) : 542 - 547