In vivo studies of titanium implant surface treatment by sandblasted, acid-etched and further anchored with ceramic of tetracalcium phosphate on osseointegration

被引:14
|
作者
Chen, Jian-Chih [1 ,2 ]
Ko, Chia-Ling [3 ,4 ,5 ]
Lin, Dan-Jae [6 ,7 ]
Wu, Hui-Yu [3 ,4 ]
Hung, Chun-Cheng [4 ,8 ]
Chen, Wen-Cheng [3 ,4 ,6 ]
机构
[1] Kaohsiung Med Univ, Coll Med, Fac Med Sch, Dept Orthoped, Kaohsiung 807, Taiwan
[2] Kaohsiung Municipal Siaogang Hosp, Dept Orthopaed, Kaohsiung 812, Taiwan
[3] Feng Chia Univ, Dept Fiber & Composite Mat, 100 Wenhwa Rd, Taichung 40740724, Taiwan
[4] Kaohsiung Med Univ, Coll Dent Med, Dent Med Devices & Mat Res Ctr, Kaohsiung 807, Taiwan
[5] Ind Technol Res Inst, Laser & Addit Mfg Technol Ctr, Hsinchu 310, Taiwan
[6] China Med Univ, Dept Dent Hyg, Taichung 404, Taiwan
[7] China Med Univ, Sch Dent, Coll Med, Taichung 404, Taiwan
[8] Kaohsiung Med Univ Hosp, Dept Prosthodont, Kaohsiung 807, Taiwan
关键词
Titanium; Calcium phosphate; Surface modification; Sandblasted and acid etched (SLA); Histological; DENTAL IMPLANTS; STABILITY; COATINGS;
D O I
10.1007/s41779-018-00292-5
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The objective was to investigate and compare the osseointegrative responses of sandblasted/acid-etched (SLA) and calcium phosphate (CaP) implants in vivo. The CaP implant was prepared by control group of SLA surface modification and anchoring with sintering ceramic of tetracalcium phosphate (TTCP) to form a mechanical interlocking film. Customized screw Ti implants (size o 2.0 mm x 6 mm length) were utilized to histologically examine the bone-to-implant contact (BIC) after implantation. The implant stability quotient scales in the postoperative implants within femurs were recorded. Subsequently, the postoperative implants were scanned using microcomputed tomography (micro-CT), and the topography was examined microscopically to analyze the BIC conditions. The SLA and CaP implant groups showed increased bone mineral density (g/cm(3)) and BIC (%). Compared with the SLA implant, the CaP implant with TTCP improved the early osteointegration of the BIC at 1-month post-operation and demonstrated quantitative effects on the BIC at 1-month post-operation. SLA and CaP implants all showed good osseointegration through micro-CT analysis (1-6 months). The current findings suggest the CaP anchoring Ti surface demonstrated improvement in early stages of osseointegration and thus shows the potential clinical benefits of TTCP anchoring on Ti surfaces in bone-level solutions.
引用
收藏
页码:799 / 806
页数:8
相关论文
共 50 条
  • [1] In vivo studies of titanium implant surface treatment by sandblasted, acid-etched and further anchored with ceramic of tetracalcium phosphate on osseointegration
    Jian-Chih Chen
    Chia-Ling Ko
    Dan-Jae Lin
    Hui-Yu Wu
    Chun-Cheng Hung
    Wen-Cheng Chen
    [J]. Journal of the Australian Ceramic Society, 2019, 55 : 799 - 806
  • [2] Efficacy of plasma treatment for surface cleansing and osseointegration of sandblasted and acid-etched titanium implants
    Bae, Gang-Ho
    Cho, Won-Tak
    Lee, Jong-Ho
    Huh, Jung-Bo
    [J]. JOURNAL OF ADVANCED PROSTHODONTICS, 2024, 16 (03): : 189 - 199
  • [3] Comparison of early osseointegration between laser-treated/acid-etched and sandblasted/acid-etched titanium implant surfaces
    Mingdeng Rong
    Haibin Lu
    Lei Wan
    Xueyang Zhang
    Xi Lin
    Shaobing Li
    Lei Zhou
    Yingtao Lv
    Yuan Su
    [J]. Journal of Materials Science: Materials in Medicine, 2018, 29
  • [4] Comparison of early osseointegration between laser-treated/acid-etched and sandblasted/acid-etched titanium implant surfaces
    Rong, Mingdeng
    Lu, Haibin
    Wan, Lei
    Zhang, Xueyang
    Lin, Xi
    Li, Shaobing
    Zhou, Lei
    Lv, Yingtao
    Su, Yuan
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2018, 29 (04)
  • [5] Biomechanical comparison of the sandblasted and acid-etched and the machined and acid-etched titanium surface for dental implants
    Li, DH
    Ferguson, SJ
    Beutler, T
    Cochran, DL
    Sittig, C
    Hirt, HP
    Buser, D
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 60 (02): : 325 - 332
  • [6] Osseointegration of chemically modified sandblasted and acid-etched titanium implant surface in diabetic rats: a histological and scanning electron microscopy study
    Nemtoi, Alexandru
    Trandafir, Violeta
    Pasca, Aurelian-Sorin
    Sindilar, Eusebiu-Viorel
    Dragan, Eliza
    Odri, Guillaume-Anthony
    Nemtoi, Ana
    Haba, Danisia
    Sapte, Elena
    [J]. ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY, 2017, 58 (03): : 881 - 886
  • [7] Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface
    Barewal, RM
    Oates, TW
    Meredith, N
    Cochran, DL
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (05) : 641 - 651
  • [8] Osseointegration of Sandblasted and Acid-Etched Implant Surfaces. A Histological and Histomorphometric Study in the Rabbit
    Velasco-Ortega, Eugenio
    Ortiz-Garcia, Ivan
    Jimenez-Guerra, Alvaro
    Nunez-Marquez, Enrique
    Moreno-Munoz, Jesus
    Luis Rondon-Romero, Jose
    Cabanillas-Balsera, Daniel
    Gil, Javier
    Munoz-Guzon, Fernando
    Monsalve-Guil, Loreto
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2021, 22 (16)
  • [9] Evaluation of an endosseous titanium implant with a sandblasted and acid-etched surface in the canine mandible: Radiographic results
    Cochran, DL
    Nummikoski, PV
    Higginbottom, FL
    Hermann, JS
    Makins, SR
    Buser, D
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (03) : 240 - 252
  • [10] Surface analysis of machined versus sandblasted and acid-etched titanium implants
    Orsini, G
    Assenza, B
    Scarano, A
    Piattelli, M
    Piattelli, A
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2000, 15 (06) : 779 - 784