Dispersive Liquid-Liquid Microextraction Coupled with Dispersive μ-Solid-Phase Extraction for the Fast Determination of Polycyclic Aromatic Hydrocarbons in Environmental Water Samples

被引:207
|
作者
Shi, Zhi-Guo [1 ]
Lee, Hian Kee [1 ]
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
关键词
GAS-CHROMATOGRAPHY; SINGLE-DROP; SOLVENT;
D O I
10.1021/ac9023632
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new two-step microextraction technique, combining dispersive liquid-liquid microextraction (DLLME) and dispersive microsolid-phase extraction (D-mu-SPE), was developed for the fast gas chromatographic-mass spectrometric determination of polycyclic aromatic hydrocarbons (PAHs) in environmental samples. A feature of the new procedure lies in that any organic solvent immiscible with water can be used as extractant in DLLME. A special apparatus, such as conical-bottom test tubes, and tedious procedures of centrifugation, refrigeration of the solvent, and then thawing it, associated with classical DLLME or similar techniques are not necessary in the new procedure, which potentially lends itself to possible automation. In the present D-mu-SPE approach, hydrophobic magnetic nanoparticles were used to retrieve the extractant of I-octanol in the DLLME step. It is noteworthy that the target of D-mu-SPE was the 1-octanol rather than the PAHs. Because of the rapid mass transfer associated with the DLLME and the D-mu-SPE steps, fast extraction could be achieved. Parameters affecting the extraction efficiency were investigated in detail. The optimal conditions were as follows: vortex at 3200 rpm in die DLLME step for 2 min and in D-mu-SPE for 1 min and then desorption by sonication for 4 min with acetonitrile as the solvent. The results demonstrated that enrichment factors ranging from 110- to 186-fold were obtained for the analytes. The limits of detection and the limits of quantification were in the range of 11.7-61.4 pg/mL and 0.04-0.21 ng/mL, respectively. The linearities were 0.5-50, 1-50, or 2-50 ng/mL for different PAHs. Finally, the two-step extraction method was successfully used for the fast determination of PAHs in river water samples. This two-step method, combining two different and efficient miniaturized techniques, provides a fast means of sample pretreatment for environmental water samples.
引用
收藏
页码:1540 / 1545
页数:6
相关论文
共 50 条
  • [1] Magnetic solid-phase extraction or dispersive liquid-liquid microextraction for pyrethroid determination in environmental samples
    Pastor-Belda, Marta
    Navarro-Jimenez, Tania
    Garrido, Isabel
    Vinas, Pilar
    Campillo, Natalia
    Fenoll, Jose
    Hernandez-Cordoba, Manuel
    [J]. JOURNAL OF SEPARATION SCIENCE, 2018, 41 (12) : 2565 - 2575
  • [2] Dispersive liquid-liquid microextraction combined with dispersive solid-phase extraction for gas chromatography with mass spectrometry determination of polycyclic aromatic hydrocarbons in aqueous matrices
    Hassan, Farah Wahidah Mohd
    Raoov, Muggundha
    Kamaruzaman, Sazlinda
    Sanagi, Mohd Marsin
    Yoshida, Nao
    Hirota, Yuichiro
    Nishiyama, Norikazu
    Yahaya, Noorfatimah
    [J]. JOURNAL OF SEPARATION SCIENCE, 2018, 41 (19) : 3751 - 3763
  • [3] Dispersive Liquid-Liquid Microextraction for the Simultaneous Determination of Parent and Nitrated Polycyclic Aromatic Hydrocarbons in Water Samples
    Borges, Barbara
    Melo, Armindo
    Ferreira, Isabel M. P. L. V. O.
    Mansilha, Catarina
    [J]. ACTA CHROMATOGRAPHICA, 2018, 30 (02) : 119 - 126
  • [4] Dispersive liquid-liquid microextraction coupled with high performance liquid chromatography for the determination of polynuclear aromatic hydrocarbons in environmental water samples
    Zhang Jianhua
    Huang Ying
    Chen Xiaoqiu
    Chen Jinhua
    Li Hui
    Chen Guonan
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2009, 27 (06) : 799 - 803
  • [5] Low toxic dispersive liquid-liquid microextraction using halosolvents for extraction of polycyclic aromatic hydrocarbons in water samples
    Leong, Mei-I
    Chang, Chu-Chi
    Fuh, Ming-Ren
    Huang, Shang-Da
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (34) : 5455 - 5461
  • [6] Deep eutectic solvents with low viscosity for the determination of polycyclic aromatic hydrocarbons in environmental water samples by dispersive liquid-liquid microextraction
    Li, Zhiqiang
    Liu, Qian
    Lu, Xiaoxiao
    Chen, Xiaomei
    Zhao, Jingchan
    [J]. MICROCHEMICAL JOURNAL, 2024, 198
  • [7] Simultaneous Dispersive Liquid-Liquid Microextraction and Determination of Different Polycyclic Aromatic Hydrocarbons in Surface Water
    Temerdashev, Zaual
    Prasad, Surendra
    Musorina, Tatiana
    Chervonnaya, Tatiana
    Arutyunyan, Zhanna
    [J]. MOLECULES, 2022, 27 (23):
  • [8] Dispersive liquid-liquid microextraction for determination of volatile aromatic hydrocarbons in water
    Pusvaskiene, Edita
    Jurkina, Aliona
    Vickackaite, Vida
    [J]. CHEMIJA, 2009, 20 (03): : 175 - 179
  • [9] Determination of hydroxylated metabolites of polycyclic aromatic hydrocarbons in sediment samples by combining subcritical water extraction and dispersive liquid-liquid microextraction with derivatization
    Wang, Xiaowei
    Lin, Li
    Luan, Tiangang
    Yang, Lihua
    Tam, Nora F. Y.
    [J]. ANALYTICA CHIMICA ACTA, 2012, 753 : 57 - 63
  • [10] Combination of solid-phase extraction and dispersive liquid-liquid microextraction for detection of cypermethrin and permethrin in environmental water
    Yan, Hongyuan
    Han, Yehong
    Du, Jingjing
    [J]. ANALYTICAL METHODS, 2012, 4 (09) : 3002 - 3006