Partial Discharges Pulse Shape Analysis at AC and DC

被引:0
|
作者
Pihera, Josef [1 ]
Hornak, Jaroslav [1 ]
Vobornik, Ales [1 ]
Kupka, Lukas [1 ]
Chladek, Svatoslav [1 ]
Haller, Rainer [1 ]
机构
[1] Univ West Bohemia, Fac Elect Engn, Reg Innovat Ctr Elect Engn, Plzen, Czech Republic
关键词
Partial discharges; Pulse shape; Measuring impedance; Statistical analysis;
D O I
10.1007/978-3-030-31676-1_52
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial discharge (PD) signal analysis is a well-known tool for monitoring the conditions of insulation systems of electrical machines and equipment. Classical analyzes of PD are mostly based on the evaluation of the phase angle of the test voltage at which partial discharges occur. At the present, the partial discharge detection is mostly based on the measurement of charging currents that are needed to resume the voltage on the sample that was there before the partial discharge occurred. Other electrical methods are, for example, the scanning of an electromagnetic field emitted during a partial discharge. Another developed methodology in the field of measuring and analyzing partial discharges is the monitoring of pulse parameters of the detected discharge. Experiments suggest that measuring the rise and fall time of the pulse edges and amplitude measurements can evaluate the partial discharge signal. Especially this method could be very helpful at the moment when partial discharges at DC are studied and evaluated. The disadvantage of partial discharges at DC is the fact there is no phase and phase angle position for PD patterns recognition. Thus, another evaluation method development is necessary for PD recognition DC. There is presented in the study an experiment where the PD pulse shapes, in the manner of rise time and fall time, were investigated at laboratory PD models at both voltage types AC and DC. The PD models simulated corona discharges. Each individual pulse of a partial discharge can be detected by a suitable scanning impedance and viewed with fast digital oscilloscopes. As has been said, there is a presumption that different discharge arrangements or even variously degraded insulating materials have different waveforms of the sensed pulses. The main monitored parameters of individual pulses are their rise time and amplitude. Since the occurrence of partial discharge is essentially a random phenomenon, statistical analysis of a significant amount of data is required. A view of the behaviour of the partial discharge pulse in various cases of the discharge activity brings different results in the observation of the pulse rise time and its amplitude in the various observed setups. Monitoring the rise time and pulse amplitude is one way of evaluating partial discharges, regardless of their superimposed position on the sine wave of the supply voltage. Thus this PD monitoring could be a part of PD evaluation at DC. These pulse parameters together with other PD analysis at DC (as pulse sequence analysis) could be used to estimate the partial discharge type as well as to evaluate the deterioration of the insulation of electrical machines.
引用
收藏
页码:549 / 559
页数:11
相关论文
共 50 条
  • [1] Classification and comparison of AC and DC partial discharges by pulse waveform analysis
    Rostaghi-Chalaki, Mojtaba
    Yousefpour, Kamran
    Kluss, Joni
    Kurum, Mehmet
    Donohoe, J. Patrick
    Park, Chanyeop
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 125
  • [2] Comparative investigation on pulse shape parameters of partial discharges in air under AC and DC voltage stress
    Luehring, Ulrich
    Wienold, Daniel
    Jenau, Frank
    [J]. 2016 51ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2016,
  • [3] Classification of Partial Discharges at AC, DC and Combined AC/DC Voltage Using Frequency Domain Analysis
    Saadati, Hassan
    Werle, P.
    Gockenbach, E.
    Borsi, Hossein
    [J]. PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 2, 2020, 599 : 1527 - 1537
  • [4] PARTIAL DISCHARGES UNDER AC AND DC TEST CONDITIONS
    Pihera, Josef
    Mraz, Petr
    Haller, Rainer
    [J]. PROCEEDINGS OF THE 14TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2013, 2013, : 237 - 242
  • [5] Partial discharge pulse shape detection and analysis under DC condition
    Li, Xiaohua
    Wu, Guangning
    Zhang, Xueqin
    Bian, Shanshan
    [J]. 2007 ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING EXPO, 2007, : 48 - 51
  • [6] Applicability of coefficients for the defect identification of partial discharges in air under AC voltage stress based on the pulse shape
    Luehring, Ulrich
    Wienold, Daniel
    [J]. 2016 IEEE 16TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2016,
  • [7] The effect of DC superimposed AC Voltage on Partial Discharges in Dielectric Bounded Cavities
    Olsen, P. K.
    Mauseth, F.
    Ildstad, E.
    [J]. 2014 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2014,
  • [8] Partial discharges at dc voltage: Their mechanism, detection and analysis
    Morshuis, PHF
    Smit, JJ
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2005, 12 (02) : 328 - 340
  • [9] Measurement and Statistical Analysis of Partial Discharges at DC Voltage
    Klueter, T.
    Wulff, J.
    Jenau, F.
    [J]. 2013 48TH INTERNATIONAL UNIVERSITIES' POWER ENGINEERING CONFERENCE (UPEC), 2013,
  • [10] PULSE-HEIGHT ANALYSIS OF PARTIAL DISCHARGES IN AIR
    FLORKOWSKA, B
    WLODEK, R
    [J]. IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1993, 28 (06): : 932 - 940