Monte Carlo Comparison of Proton and Helium-ion Minibeam Generation Techniques

被引:8
|
作者
Schneider, Tim [1 ,2 ]
De Marzi, Ludovic [3 ,4 ]
Patriarca, Annalisa [5 ]
Prezado, Yolanda [6 ]
机构
[1] Univ Paris Saclay, IJCLab, CNRS IN2P3, Orsay, France
[2] Univ Paris, IJCLab, Orsay, France
[3] Univ Paris Saclay, PSL Res Univ, Inst Curie, LITO, Orsay, France
[4] PSL Res Univ, Inst Curie, Dept Radiat Oncol, Proton Therapy Ctr,Ctr Univ, Orsay, France
[5] PSL Res Univ, Inst Curie, Proton Therapy Ctr, Ctr Univ, Orsay, France
[6] Univ PSL, Inst Curie, CNRS UMR3347, Inserm U1021,Signalisat Radiobiol & Canc, Orsay, France
基金
欧洲研究理事会;
关键词
proton minibeam radiation therapy; collimator; magnetic focusing; Monte Carlo simulations; spatial fractionation of the dose; helium ions;
D O I
10.3389/fphy.2021.595721
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Proton minibeam radiation therapy (pMBRT) is a novel therapeutic strategy that combines the normal tissue sparing of submillimetric, spatially fractionated beams with the improved dose deposition of protons. In contrast to conventional approaches which work with comparatively large beam diameters (5 mm to several centimetres) producing laterally homogeneous fields, pMBRT uses submillimetric minibeams to create a distinct spatial modulation of the dose featuring alternating regions of high dose (peaks) and low dose (valleys). This spatial fractionation can increase the tolerance of normal tissue and may allow a safe dose escalation in the tumour. Important quantities in this context are the valley dose as well as the peak-to-valley dose ratio (PVDR). Creating submillimetric proton beams for clinical applications is a challenging task that until now has been realized with mechanical collimators (metal blocks with thin slits or holes). However, this method is inherently inefficient, inflexible and creates undesirable secondary neutrons. We therefore recently proposed a method for obtaining clinical minibeams using only magnetic focusing. In this study, we performed Monte Carlo simulations in order to compare minibeams generated using the new method of magnetic focusing with two techniques involving mechanical collimators (collimator and broad beam irradiation, collimator and pencil beam scanning). The dose deposition in water was simulated and dosimetric aspects [beam broadening, depth-dose profiles, PVDR and Bragg-peak-to-entrance dose ratio (BEDR)] as well as irradiation efficiencies were evaluated. Apart from protons, we also considered helium ions which, due to their reduced lateral scattering and sharper Bragg peak, may present a promising alternative for minibeam radiation therapy. Magnetically focused minibeams exhibited a 20-60 times higher PVDR than mechanically collimated minibeams and yielded an increase in irradiation efficiency of up to two orders of magnitude. Compared to proton minibeams, helium ion minibeams were found to broaden at a slower rate and yield an even higher PVDR (at the same minibeam spacing) as well as a more favourable BEDR. Moreover, the simulations showed that methods developed for proton minibeams are suitable for the generation of helium ion minibeams.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Proton and helium ion radiotherapy for meningioma tumors: a Monte Carlo-based treatment planning comparison
    Tessonnier, Thomas
    Mairani, Andrea
    Chen, Wenjing
    Sala, Paola
    Cerutti, Francesco
    Ferrari, Alfredo
    Haberer, Thomas
    Debus, Juergen
    Parodi, Katia
    [J]. RADIATION ONCOLOGY, 2018, 13
  • [2] Proton and helium ion radiotherapy for meningioma tumors: a Monte Carlo-based treatment planning comparison
    Thomas Tessonnier
    Andrea Mairani
    Wenjing Chen
    Paola Sala
    Francesco Cerutti
    Alfredo Ferrari
    Thomas Haberer
    Jürgen Debus
    Katia Parodi
    [J]. Radiation Oncology, 13
  • [3] DEPTH DISTRIBUTION OF DAMAGE IN HELIUM-ION AND PROTON IRRADIATED NICKEL
    EZAWA, T
    SUGIMOTO, M
    NIWASE, K
    SASAKI, S
    IWASE, A
    IWATA, T
    FUJITA, FE
    [J]. JOURNAL OF NUCLEAR MATERIALS, 1991, 179 : 974 - 977
  • [4] Proton and photon Minibeam Radiation Therapy (MBRT): a micro and nanodosimetry Monte Carlo study
    Dos Santos, M.
    Salmon, R.
    Prezado, Y.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S77 - S77
  • [5] Helium CT: Monte Carlo simulation results for an ideal source and detector with comparison to proton CT
    Piersimoni, Pierluigi
    Faddegon, Bruce A.
    Mendez, Jose Ramos
    Schulte, Reinhard W.
    Volz, Lennart
    Seco, Joao
    [J]. MEDICAL PHYSICS, 2018, 45 (07) : 3264 - 3274
  • [6] L-SHELL IONIZATIONS OF AU, BI, AND U IN PROTON AND HELIUM-ION IMPACT
    TAWARA, H
    ISHII, K
    MORITA, S
    KAJI, H
    SHIOKAWA, T
    [J]. PHYSICAL REVIEW A, 1975, 11 (05) : 1560 - 1570
  • [7] Comparison of linear energy transfer scoring techniques in Monte Carlo simulations of proton beams
    Granville, Dal A.
    Sawakuchi, Gabriel O.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (14): : N283 - N291
  • [8] A comparison of neon versus helium ion beam induced deposition via Monte Carlo simulations
    Timilsina, Rajendra
    Smith, Daryl A.
    Rack, Philip D.
    [J]. NANOTECHNOLOGY, 2013, 24 (11)
  • [9] COMPARISON OF CORRELATED MONTE-CARLO TECHNIQUES
    PREEG, WE
    TSANG, JSK
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 43 : 628 - 630
  • [10] 2S AND 2P EXCITATIONS OF HYDROGEN BY PROTON AND HELIUM-ION IMPACT
    FLANNERY, MR
    [J]. JOURNAL OF PHYSICS PART B ATOMIC AND MOLECULAR PHYSICS, 1969, 2 (10): : 1044 - &