Profiling of selenium removal in hydrogen ambient zone-refined tellurium bar using RF-GDOES

被引:10
|
作者
Anil, G. [1 ]
Reddy, M. R. P. [1 ]
Prasad, D. S. [1 ]
Ali, S. T. [1 ]
Munirathnam, N. R. [1 ]
Prakash, T. L. [1 ]
机构
[1] CMET, Ultrapure Mat Div, Hyderabad 500051, Andhra Pradesh, India
关键词
tellurium; zone refining; segregation coefficient; radio-frequency glow discharge optical emission spectrometer;
D O I
10.1016/j.matchar.2006.03.013
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Ultrapure tellurium (Te) metal has become an important metal in the strategic sector for fabricating high performance infrared devices for thermal imaging and night vision cameras. Zone refining (ZR) is a proven technique for purification of Te. Selenium (Se), present as an impurity in Te, is not easily removed by ZR under normal conditions as the segregation coefficient (K) is around 0.44-0.50. Hence, ZR was performed in a hydrogen atmosphere, during which Se gets converted to hydrogen selenide at the molten moving zones and carried away into the sodium hydroxide scrubbers. In this study a radio-frequency glow discharge optical emission spectrometer (RF-GDOES) was used for determining the concentration of Se along the 56 cm Te zone-refined bar. It was observed that the initial concentration of 1100 ppb Se was decreased to 30 ppb after 2 cycles. (c) 2006 Elsevier Inc. All rights reserved.