Validation of a wearable biosensor device for vital sign monitoring in septic emergency department patients in Rwanda

被引:17
|
作者
Garbern, Stephanie C. [1 ]
Mbanjumucyo, Gabin [2 ]
Umuhoza, Christian [3 ,4 ]
Sharma, Vinay K. [5 ]
Mackey, James [6 ]
Tang, Oliver [7 ]
Martin, Kyle D. [1 ]
Twagirumukiza, Francois R. [2 ]
Rosman, Samantha L. [8 ]
McCall, Natalie [9 ]
Wegerich, Stephan W. [10 ]
Levine, Adam C. [1 ]
机构
[1] Brown Univ, Warren Alpert Med Sch, Dept Emergency Med, 55 Claverick St,2nd Floor, Providence, RI 02906 USA
[2] Univ Rwanda, Dept Anesthesia Emergency Med & Crit Care, Kigali, Rwanda
[3] Univ Teaching Hosp Kigali, Dept Pediat, Pediat Emergency Unit, Kigali, Rwanda
[4] Univ Rwanda, Dept Pediat, Kigali, Rwanda
[5] Michigan State Univ, Coll Human Med, E Lansing, MI 48824 USA
[6] Columbia Univ, Mailman Sch Publ Hlth, New York, NY USA
[7] Brown Univ, Providence, RI 02912 USA
[8] Boston Childrens Hosp, Div Emergency Med, Boston, MA USA
[9] Yale Univ, Dept Pediat, New Haven, CT 06520 USA
[10] PhysIQ Inc, Chicago, IL USA
来源
DIGITAL HEALTH | 2019年 / 5卷
关键词
Sepsis; low; and middle-income country; wearable technology; biosensor; critical care; resource-limited; continuous vital signs; wearable device; Rwanda; emergency medicine; EARLY WARNING SCORE; SEPSIS; GUIDELINES; MORTALITY; CARE; MEDICINE; EVENTS; SYSTEM; IMPACT; UNIT;
D O I
10.1177/2055207619879349
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objective Critical care capabilities needed for the management of septic patients, such as continuous vital sign monitoring, are largely unavailable in most emergency departments (EDs) in low- and middle-income country (LMIC) settings. This study aimed to assess the feasibility and accuracy of using a wireless wearable biosensor device for continuous vital sign monitoring in ED patients with suspected sepsis in an LMIC setting. Methods This was a prospective observational study of pediatric (>= 2 mon) and adult patients with suspected sepsis at the Kigali University Teaching Hospital ED. Heart rate, respiratory rate and temperature measurements were continuously recorded using a wearable biosensor device for the duration of the patients' ED course and compared to intermittent manually collected vital signs. Results A total of 42 patients had sufficient data for analysis. Mean duration of monitoring was 32.8 h per patient. Biosensor measurements were strongly correlated with manual measurements for heart rate (r = 0.87, p < 0.001) and respiratory rate (r = 0.75, p < 0.001), although were less strong for temperature (r = 0.61, p < 0.001). Mean (SD) differences between biosensor and manual measurements were 1.2 (11.4) beats/min, 2.5 (5.5) breaths/min and 1.4 (1.0)degrees C. Technical or practical feasibility issues occurred in 12 patients (28.6%) although were minor and included biosensor detachment, connectivity problems, removal for a radiologic study or exam, and patient/parent desire to remove the device. Conclusions Wearable biosensor devices can be feasibly implemented and provide accurate continuous heart rate and respiratory rate monitoring in acutely ill pediatric and adult ED patients with sepsis in an LMIC setting.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Vital Sign Monitoring During Crowding in Emergency Department Triage Using a Non-invasive Wearable Biosensor
    Rovenolt, G.
    Hall, K.
    Tenzer, M.
    Davenport, P.
    Tracy, S.
    Kuehl, D.
    ANNALS OF EMERGENCY MEDICINE, 2023, 82 (04) : S7 - S7
  • [2] Advantage of Vital Sign Monitoring Using a Wireless Wearable Device for Predicting Septic Shock in Febrile Patients in the Emergency Department: A Machine Learning-Based Analysis
    Choi, Arom
    Chung, Kyungsoo
    Chung, Sung Phil
    Lee, Kwanhyung
    Hyun, Heejung
    Kim, Ji Hoon
    SENSORS, 2022, 22 (18)
  • [3] THE FACTORS THAT AFFECT THE FREQUENCY OF VITAL SIGN MONITORING IN THE EMERGENCY DEPARTMENT
    Johnson, Kimberly D.
    Winkelman, Chris
    Burant, Christopher J.
    Dolansky, Mary
    Totten, Vicken
    JOURNAL OF EMERGENCY NURSING, 2014, 40 (01) : 27 - 35
  • [4] Wearable At-Home Vital Sign Monitoring
    Hammett, Krisila L.
    Paquin, Colin J.
    Pasquel, Ryan J.
    Dow, Douglas E.
    2022 IEEE 13TH ANNUAL UBIQUITOUS COMPUTING, ELECTRONICS & MOBILE COMMUNICATION CONFERENCE (UEMCON), 2022, : 76 - 83
  • [5] Continuous vital sign monitoring using a wearable patch sensor in obese patients: a validation study in a clinical setting
    Kant, Niels
    Peters, Guido M.
    Voorthuis, Brenda J.
    Groothuis-Oudshoorn, Catharina G. M.
    Koning, Mark V.
    Witteman, Bart P. L.
    Rinia-Feenstra, Myra
    Doggen, Carine J. M.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (05) : 1449 - 1459
  • [6] Continuous vital sign monitoring using a wearable patch sensor in obese patients: a validation study in a clinical setting
    Niels Kant
    Guido M. Peters
    Brenda J. Voorthuis
    Catharina G. M. Groothuis-Oudshoorn
    Mark V. Koning
    Bart P. L. Witteman
    Myra Rinia-Feenstra
    Carine J. M. Doggen
    Journal of Clinical Monitoring and Computing, 2022, 36 : 1449 - 1459
  • [7] Analysis of a data-fusion system for continuous vital sign monitoring in an emergency department
    Wilson, Sarah J.
    Wong, David
    Pullinger, Richard M.
    Way, Rob
    Clifton, David A.
    Tarassenko, Lionel
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2016, 23 (01) : 28 - 32
  • [8] The reliability of vital sign measurements in the UCLA emergency department
    Edmonds, Z
    Mower, W
    Lovato, L
    Lomeli, R
    JOURNAL OF INVESTIGATIVE MEDICINE, 2000, 48 (01) : 40A - 40A
  • [9] A Retrospective Observational Study of Continuous Wireless Vital Sign Monitoring via a Medical Grade Wearable Device on Hospitalized Floor Patients
    Weller, Grant B.
    Mault, James
    Ventura, Maria Eloisa
    Adams, Justin
    Campbell, Frank J.
    Tremper, Kevin K.
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (16)
  • [10] Wireless Chest Wearable Vital Sign Monitoring Platform for Hypertension
    Janjua, G.
    Guldenring, D.
    Finlay, D.
    McLaughlin, J.
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 821 - 824