Heterophilic antibodies causing falsely high serum calcitonin values

被引:20
|
作者
Papapetrou, P. D.
Polymeris, A.
Karga, H.
Vaiopoulos, G.
机构
[1] Univ Athens, Sch Med, Dept Internal Med 1, Laikon Hosp, GR-11527 Athens, Greece
[2] Alexandra Hosp, Div Endocrinol 2, Athens, Greece
关键词
heterophilic antibodies; high serum calcitonin;
D O I
10.1007/BF03349197
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Heterophilic antibodies (HA) may interfere in some immunoassays, causing falsely high hormone values, of wich practitioners should be aware when measuring calcitonin (CT) used as tumor marker for medullary thyroid carcinoma (MTC). We studied four patients with thyroid nodules, three of whom underwent surgical neck exploration, after an erroneous diagnosis of MTC because of falsely high serum CT eventually proved to be due to HA. One patient had a lingual thyroid, two autoimmune thyroiclitis and the fourth a colloid goiter. The minimal incremental CT response to calcium infusion raised our suspicion of possible false high CT values due to HA. There was no linearity of the CT values obtained by testing serial dilutions of the sera in the CT assay, which employs two monoclonal mouse anti-CT antibodies. Addition of normal mouse gamma globulin eliminated the interference by HA in the sera of two patients. Serum assayed in a polyclonal radioimmunoassay using goat anti-CT antibodies gave normal CT values. Finally, incubation of the sera in Heterophilic Blocking Tubes((R)) (HBT) eliminated the false CT immunoreactivity. A spontaneous change of the CT serum concentrations was noticed in three patients over several months, apparently due to changing titles of HA. We suggest that, in patients a) whose CT response to calcium or pentagastrin infusion is minimal despite high basal CT values, b) with autoimmune thyroiditis and c) in whom an unexpected change in serum CT concentrations occurs, the possibility of spuriously high CT values because of circulating HA should be considered.
引用
收藏
页码:919 / 923
页数:5
相关论文
共 50 条
  • [1] Heterophilic antibodies causing falsely high serum calcitonin values
    P. D. Papapetrou
    A. Polymeris
    H. Karga
    G. Vaiopoulos
    Journal of Endocrinological Investigation, 2006, 29 : 919 - 923
  • [2] HETEROPHILIC ANTIBODIES AGAINST RABBIT SERUM CAUSING FALSELY ELEVATED GONADOTROPIN-LEVELS
    BERGLUND, L
    HOLMBERG, NG
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1989, 68 (04) : 377 - 378
  • [3] HETEROPHILIC SERUM ANTIBODIES - A CAUSE FOR FALSELY ELEVATED SERUM THYROTROPIN LEVELS
    BRENNAN, MD
    KLEE, GG
    PREISSNER, CM
    HAY, ID
    MAYO CLINIC PROCEEDINGS, 1987, 62 (10) : 894 - 898
  • [4] Falsely elevated serum tryptase levels due to heterophilic antibodies
    Arlettaz, L.
    Roux-Lombard, P.
    Ribi, C.
    Eigenmann, P.
    Chizzolini, C.
    ALLERGY, 2010, 65 : 522 - 523
  • [5] HETEROPHILIC ANTIBODIES CAUSING FALSELY RAISED THYROID-STIMULATING-HORMONE RESULT
    HEDENBORG, G
    PETTERSSON, T
    CARLSTROM, A
    LANCET, 1979, 2 (8145): : 755 - 755
  • [6] Thyroidectomy due to interference of serum calcitonin measurement by heterophilic antibodies
    Vogeser, M.
    Kratzsch, J.
    Otto, C.
    EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY & DIABETES, 2013, 121 (03)
  • [7] Falsely elevated serum tryptase due to interfering heterophilic antibodies in patients with suspected mastocytosis
    Hausmann, O.
    Arlettaz, L.
    Eichhorn, L.
    Cuhat, I
    Roux-Lombard, P.
    Schmid-Grendelmeier, P.
    Helbling, A.
    Brockow, K.
    Chizzolini, C.
    ALLERGY, 2011, 66 : 331 - 331
  • [8] HETEROPHILIC ANTIBODIES IN HUMAN SERA CAUSING FALSELY INCREASED RESULTS IN THE CA-125 IMMUNOFLUOROMETRIC ASSAY
    BOERMAN, OC
    SEGERS, MFG
    POELS, LG
    KENEMANS, P
    THOMAS, CMG
    CLINICAL CHEMISTRY, 1990, 36 (06) : 888 - 891
  • [9] Heterophile antibodies may cause falsely lowered serum cortisol values
    M. J. Bolland
    W. W. Chiu
    J. S. Davidson
    M. S. Croxson
    Journal of Endocrinological Investigation, 2005, 28 : 643 - 645
  • [10] Heterophile antibodies may cause falsely lowered serum cortisol values
    Bolland, MJ
    Chiu, WW
    Davidson, JS
    Croxson, MS
    JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 2005, 28 (07) : 643 - 645