摘要
The paper presents a high sensitivity TLD system, designed for the survey of the environmental radioactivity. It is based on the use of TL detectors type L(1)F:Mg, Cu, P, commercially known as GR-200A. The dosimeter designed in our Institute. contains 3 detectors. and the measurement value is calculated as the arithmetic mean A very sensitive, TL Reader, READER ANALYSER RA'94 was chosen and ail optimal thermal cycle was designed. such as to enhance the measurement performances For each placement, a set of 3 dosimeters is used. and Survey intervals from 1 to 100 days, depending on the radioactivity level and reporting requirements. are selected. The technical characteristics of the system were determined by exposing the dosimeters in reference X and gamma radiation Fields, such as required by the IEC standard 61066 2006 "Thermoluminiscence dosimetry systems for personal and environmental monitoring" The main technical parameters are of highest quality and recommend it for use in the survey of the environmental radioactivity, at the level of ambient dose equivalent rate, due to normal natural radioactivity, in open areas. The paper describes the method of characterization and measurement results. as well as their relevance.
引用
收藏
页码:711 / 719
页数:9
相关论文
共 50 条
  • [1] A TLD system for environmental monitoring
    Prokic, M
    [J]. RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 153 - 156
  • [2] ENVIRONMENTAL MONITORING WITH TLD
    BECKER, K
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1972, 104 (02): : 405 - &
  • [3] Environmental radioactivity monitoring
    Bayer, A
    [J]. KERNTECHNIK, 2004, 69 (5-6) : 203 - 203
  • [4] A system for archiving and reporting environmental radioactivity monitoring data
    McGinnity, P.
    Currivan, L.
    Fitzgerald, A.
    Pollard, D.
    [J]. RADIOPROTECTION, 2011, 46 (06) : S699 - S703
  • [5] Environmental radioactivity monitoring in Portugal
    Madruga, M. J.
    [J]. APPLIED RADIATION AND ISOTOPES, 2008, 66 (11) : 1639 - 1643
  • [6] TLD SYSTEM FOR RADIOTHERAPY MONITORING
    DALGLEISH, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (03): : 465 - 467
  • [7] Environmental radioactivity monitoring in Latvia
    Berzins, J
    Alksnis, J
    Bute, V
    Upitis, I
    Ljulko, I
    Vasiljeva, T
    [J]. IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 2, 1996, : B596 - B598
  • [8] RADIOACTIVITY STANDARDS FOR ENVIRONMENTAL MONITORING
    COURSEY, BM
    HUTCHINSON, JMR
    LUCAS, LL
    MANN, WB
    MATSUMURA, T
    NOYCE, JR
    [J]. JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1978, 43 (02): : 451 - 460
  • [9] MANUAL OR AUTOMATED AND COMPUTERIZED TLD SYSTEM FOR PERSONNEL AND ENVIRONMENTAL RADIATION EXPOSURE MONITORING
    ZENDLE, R
    SCHUNICH.BF
    CHAMPAGN.RJ
    [J]. HEALTH PHYSICS, 1973, 25 (03): : 331 - 331
  • [10] AUTOMATED TLD SYSTEM FOR PERSONAL MONITORING
    MUSILEK, L
    [J]. CESKOSLOVENSKY CASOPIS PRO FYSIKU SEKCE A, 1974, 24 (04): : 397 - 398