Degeneration of patellar cartilage in patients with recurrent patellar dislocation following conservative treatment: evaluation with delayed gadolinium-enhanced magnetic resonance imaging of cartilage

被引:17
|
作者
Watanabe, A. [1 ]
Obata, T. [2 ]
Ikehira, H. [2 ]
Ueda, T. [3 ]
Moriya, H. [4 ]
Wada, Y. [5 ]
机构
[1] Teikyo Univ, Chiba Med Ctr, Dept Radiol, Chiba 2990111, Japan
[2] Natl Inst Radiol Sci, Dept Biophys, Mol Imaging Ctr, Chiba 260, Japan
[3] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
[4] Chiba Univ, Dept Orthoped Surg, Chiba, Japan
[5] Teikyo Univ, Chiba Med Ctr, Dept Orthoped Surg, Chiba 2990111, Japan
关键词
Magnetic resonance imaging; Glycosaminoglycan; Recurrent patellar dislocation; Cartilage degeneration; ARTICULAR-CARTILAGE; CHONDROMALACIA PATELLAE; GLYCOSAMINOGLYCAN CONTENT; KNEE OSTEOARTHRITIS; MRI; THICKNESS; PATHOLOGY; CONTRAST; 3.0T;
D O I
10.1016/j.joca.2009.05.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To examine the characteristics of cartilage degeneration in patients with recurrent patellar dislocation (RPD) following conservative treatment using delayed gadolinium-enhanced magnetic resonance imaging (MRI) of cartilage (dGEMRIC). Design: This study evaluated three groups of knees: group 1, 35 knees from both knees of patients with bilateral RPD and dislocated side knees of patients with unilateral RPD; group II, 15 non-dislocated side knees of patients with unilateral RPD; and group III, 20 knees from both knees of healthy volunteers. Differences in post-contrast T1 [T1(Gd)] of cartilage at both medial and lateral facets between groups 1, II and III were analyzed. For group I, possible relationships were evaluated between T1 (Gd) of cartilage and patient age, length of time between the initial dislocation and MRI and the total number of dislocations between the initial dislocation and MRI for both medial and lateral facets. Results: The mean T1 (Gd) of cartilage at medial facets for groups 1, 11 and III were 411 +/- 46 ms, 465 +/- 38 ms and 490 +/- 29 ms, respectively; there were significant differences between these means (P < 0.05). The mean T1 (Gd) of cartilage at lateral facets for groups I, II and III were 426 +/- 53 ms, 466 +/- 45 ms and 510 +/- 36 ms, respectively; there were also significant differences between these means (P < 0.05). Significant correlations were observed between T1 (Gd) of cartilage for both medial and lateral facets and length of time between the initial dislocation and MRI (P < 0.05). No other correlations were significant. Conclusion: dGEMRIC may be a useful method to monitor glycosaminoglycan concentration in patients with RPD following conservative treatment. (C) 2009 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1546 / 1553
页数:8
相关论文
共 50 条
  • [1] Delayed Gadolinium-Enhanced Magnetic Resonance Imaging of Cartilage (dGEMRIC) in Femoacetabular Impingement
    Mamisch, Tallal Charles
    Kain, Micheal Sean Hillega
    Bittersohl, Bernd
    Apprich, Sebastian
    Werlen, Stefan
    Beck, Martin
    Siebenrock, Klaus Arno
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (09) : 1305 - 1311
  • [2] The Glycosaminoglycan Content of Hip Cartilage in Osteonecrosis of Femoral Head: Evaluation with Delayed Gadolinium-Enhanced Magnetic Resonance Imaging of Cartilage
    Zhang, Qidong
    Guo, Wanshou
    Chen, Yan
    Zhao, Qichao
    Liu, Zhaohui
    Wang, Weiguo
    CARTILAGE, 2021, 12 (01) : 70 - 75
  • [3] Delayed Gadolinium-Enhanced Magnetic Resonance Imaging of Cartilage: Clinical Associations in Obese Adults
    Anandacoomarasamy, Ananthila
    Giuffre, Bruno M.
    Leibman, Steven
    Caterson, Ian D.
    Smith, Garett S.
    Fransen, Marlene
    Sambrook, Philip N.
    March, Lyn M.
    JOURNAL OF RHEUMATOLOGY, 2009, 36 (05) : 1056 - 1062
  • [4] Delayed gadolinium-enhanced magnetic resonance imaging of hip joint cartilage: pearls and pitfalls
    Bittersohl, Bernd
    Zilkens, Christoph
    Kim, Young-Jo
    Werlen, Stefan
    Siebenrock, Klaus A.
    Mamisch, Tallal C.
    Hosalkar, Harish S.
    ORTHOPEDIC REVIEWS, 2011, 3 (02) : 45 - 50
  • [5] Automatic Cartilage Segmentation for Delayed Gadolinium-Enhanced Magnetic Resonance Imaging of Hip Joint Cartilage: A Feasibility Study
    Hesper, Tobias
    Bittersohl, Bernd
    Schleich, Christoph
    Hosalkar, Harish
    Krauspe, Ruediger
    Krekel, Peter
    Zilkens, Christoph
    CARTILAGE, 2020, 11 (01) : 32 - 37
  • [6] Application of functional magnetic resonance imaging for evaluation of cartilage injury effect on knee joint function by recurrent patellar dislocation
    Chen, Yanbo
    Wang, Zijie
    Zhang, Shenlu
    Jin, Chengzhe
    MEDICINE, 2023, 102 (44) : E35902
  • [7] Assessment of early osteoarthritis in hip dysplasia with delayed gadolinium-enhanced magnetic resonance imaging of cartilage
    Kim, YJ
    Jaramillo, D
    Millis, MB
    Gray, ML
    Burstein, D
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (10): : 1987 - 1992
  • [8] Delayed Gadolinium-Enhanced Magnetic Resonance Imaging of Cartilage Values in Hips With Bone Marrow Lesions
    Jones, Carly E.
    Cibere, Jolanda
    Qian, Hong
    Zhang, Honglin
    Guo, Yimeng
    Russell, David
    Forster, Bruce B.
    Wong, Hubert
    Esdaile, John M.
    Wilson, David R.
    ARTHRITIS CARE & RESEARCH, 2022, 74 (12) : 1997 - 2004
  • [9] Delayed Gadolinium-Enhanced MR Imaging of Cartilage (dGEMRIC) following ACL injury
    Fleming, B. C.
    Oksendahl, H. L.
    Mehan, W. A.
    Portnoy, R.
    Fadale, P. D.
    Hulstyn, M. J.
    Bowers, M. E.
    Machan, J. T.
    Tung, G. A.
    OSTEOARTHRITIS AND CARTILAGE, 2010, 18 (05) : 662 - 667
  • [10] Delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC), after slipped capital femoral epiphysis
    Zilkens, Christoph
    Miese, Falk
    Bittersohl, Bernd
    Jaeger, Marcus
    Schultz, Johannes
    Holstein, Arne
    Kim, Young-Jo
    Millis, Michael B.
    Mamisch, Tallal C.
    Krauspe, Ruediger
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (03) : 400 - 406