Prevalence of Failure due to Adverse Reaction to Metal Debris in Modern, Medium and Large Diameter Metal-on-Metal Hip Replacements - The Effect of Novel Screening Methods: Systematic Review and Metaregression Analysis

被引:31
|
作者
Reito, Aleksi [1 ]
Lainiala, Olli [1 ]
Elo, Petra [1 ]
Eskelinen, Antti [1 ]
机构
[1] Coxa Hosp Joint Replacement, Biokatu 6b, Tampere 33900, Finland
来源
PLOS ONE | 2016年 / 11卷 / 03期
关键词
ARTICULAR SURFACE REPLACEMENT; 5-YEAR FOLLOW-UP; SINGLE SURGEON SERIES; RESURFACING ARTHROPLASTY; ION LEVELS; FAILED METAL; FEMORAL-HEAD; PSEUDOTUMOR FORMATION; CONSECUTIVE HIPS; ACETABULAR CUP;
D O I
10.1371/journal.pone.0147872
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Metal-on-metal (MoM) hip replacements were used for almost a decade before adverse reactions to metal debris (ARMD) were found to be a true clinical problem. Currently, there is a paucity of evidence regarding the usefulness of systematic screening for ARMD. We implemented a systematic review and meta-analysis to establish the prevalence of revision confirmed ARMD stratified by the use of different screening protocols in patients with MoM hip replacements. Five levels of screening were identified: no screening (level 0), targeted blood metal ion measurement and/or cross-sectional imaging (level 1), metal ion measurement without imaging (level 2), metal ion measurement with targeted imaging (level 3) and comprehensive screening (both metal ions and imaging for all; level 4). 122 studies meeting our eligibility criteria were included in analysis. These studies included 144 study arms: 100 study arms with hip resurfacings, 33 study arms with large-diameter MoM total hip replacements (THR), and 11 study arms with medium-diameter MoM THRs. For hip resurfacing, the lowest prevalence of ARMD was seen with level 0 screening (pooled prevalence 0.13%) and the highest with level 4 screening (pooled prevalace 9.49%). Pooled prevalence of ARMD with level 0 screening was 0.29% and with level 4 screening 21.3% in the large-diameter MoM THR group. In metaregression analysis of hip resurfacings, level 4 screening was superior with regard to prevalence of ARMD when compared with other levels. In the large diameter THR group level 4 screening was superior to screening 0,2 and 3. These outcomes were irrespective of follow-up time or study publication year. With hip resurfacings, routine cross-sectional imaging regardless of clinical findings is advisable. It is clear, however, that targeted metal ion measurement and/or imaging is not sufficient in the screening for ARMD in any implant concepts. However, economic aspects should be weighed when choosing the preferred screening level.
引用
收藏
页数:32
相关论文
共 11 条
  • [1] Revision of metal-on-metal hip replacements and resurfacings for adverse reaction to metal debris: a systematic review of outcomes
    Matharu, Gulraj S.
    Pynsent, Paul B.
    Dunlop, David J.
    [J]. HIP INTERNATIONAL, 2014, 24 (04) : 311 - 320
  • [2] Predictors of time to revision and clinical outcomes following revision of metal-on-metal hip replacements for adverse reaction to metal debris
    Matharu, G. S.
    Pynsent, P. B.
    Sumathi, V. P.
    Mittal, S.
    Buckley, C. D.
    Dunlop, D. J.
    Revell, P. A.
    Revell, M. P.
    [J]. BONE & JOINT JOURNAL, 2014, 96B (12): : 1600 - 1609
  • [3] Large-Diameter Modular Metal-on-Metal Total Hip Arthroplasty Incidence of Revision for Adverse Reaction to Metallic Debris
    Barrett, William P.
    Kindsfater, Kirk A.
    Lesko, James P.
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 976 - 983
  • [4] Adverse reaction to metal debris after small-head diameter metal-on-metal total hip arthroplasty: an increasing concern
    D'Angelo, Fabio
    Tanas, Davide
    Gallazzi, Enrico
    Zagra, Luigi
    [J]. HIP INTERNATIONAL, 2018, 28 : 35 - 42
  • [5] Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty
    Mokka, Jari
    Junnila, Mika
    Seppanen, Matti
    Virolainen, Petri
    Polonen, Tuukka
    Vahlberg, Tero
    Mattila, Kimmo
    Tuominen, Esa K. J.
    Rantakokko, Juho
    Aarimaa, Ville
    Kukkonen, Juha
    Makela, Keijo T.
    [J]. ACTA ORTHOPAEDICA, 2013, 84 (06) : 549 - 554
  • [6] Effect of bearing size on the long-term wear, wear debris, and ion levels of large diameter metal-on-metal hip replacements -: An in vitro study
    Leslie, Ian
    Williams, Sophie
    Brown, Chris
    Isaac, Graham
    Jin, Zhongmin
    Ingham, Eileen
    Fisher, John
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 87B (01) : 163 - 172
  • [7] Systematic Screening of Adverse Reactions to Metal Debris after Recap-M2A-Magnum Metal-on-Metal Total Hip Arthroplasty
    Mantymaki, H.
    Junnila, M.
    Lankinen, P.
    Seppanen, M.
    Vahlberg, T.
    Makela, K. T.
    [J]. SCANDINAVIAN JOURNAL OF SURGERY, 2017, 106 (04) : 342 - 349
  • [8] Medium-term results following large diameter metal-on-metal total hip arthroplasty: increasing failure after 6 years
    Dhotare, Satish V.
    Shivarathre, Deepak G.
    Croitoru, Cristina
    Armstrong, Catherine
    Kapoor, Birender
    Peter, Viju K.
    [J]. HIP INTERNATIONAL, 2016, 26 (03) : 226 - 232
  • [9] High failure rates with a large-diameter hybrid metal-on-metal total hip replacement CLINICAL, RADIOLOGICAL AND RETRIEVAL ANALYSIS
    Bolland, B. J. R. F.
    Culliford, D. J.
    Langton, D. J.
    Millington, J. P. S.
    Arden, N. K.
    Latham, J. M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (05): : 608 - 615
  • [10] Which factors influence the rate of failure following metal-on-metal hip arthroplasty revision surgery performed for adverse reactions to metal debris? AN ANALYSIS FROM THE NATIONAL JOINT REGISTRY FOR ENGLAND AND WALES
    Matharu, G. S.
    Judge, A.
    Pandit, H. G.
    Murray, D. W.
    [J]. BONE & JOINT JOURNAL, 2017, 99B (08): : 1020 - 1027