Dynamic Characterization and Vibration Analysis of a Four-Story Mass Timber Building

被引:21
|
作者
Mugabo, Ignace [1 ,2 ]
Barbosa, Andre R. [1 ]
Riggio, Mariapaola [2 ]
机构
[1] Oregon State Univ, Sch Civil & Construct Engn, Corvallis, OR 97331 USA
[2] Oregon State Univ, Dept Wood Sci & Engn, Corvallis, OR USA
基金
美国食品与农业研究所;
关键词
cross-laminated timber; enhanced frequency domain decomposition; finite element modeling; light-framed shear walls; mass timber building; operational modal analysis; stochastic subspace identification;
D O I
10.3389/fbuil.2019.00086
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Mass timber construction has been gaining momentum in multi-story residential and commercial construction sectors in North America. As taller mass timber buildings are being planned and constructed, in-situ dynamic tests of this type of construction can be performed to further validate their design and use. As part of this larger effort, an in-situ dynamic characterization testing campaign based on ambient vibration measurements was conducted on a recently constructed four-story mass timber building located in Portland, Oregon. The building features cross-laminated timber (CLT) floors, a glued laminated timber (GLT) framing gravity system, and light-frame shear walls and steel HSS hold-downs that compose the lateral resisting system of the building. Ambient vibration acceleration testing data were collected using 18 accelerometers that were wired to a portable data acquisition system in two experimental setups. Approximately 2 h of bi-directional horizontal acceleration data were recorded. In this paper, two operational modal analysis methods are used for estimating the modal parameters (frequency, damping, and mode shapes) based on the data collected. In addition, a multi-stage linear Finite Element (FE) model updating procedure is presented for this building type and the FE estimates of frequencies and mode shapes are compared to estimates from the collected data. The calibrated FE model provides confidence to the operational modal results and presents a comprehensive modal characterization of the building. At ambient levels of excitation, the developed FE model suggests that stiffness of the non-structural elements, such as the exterior wall cladding, and glazing affects the modal response of the building considerably. Lessons learnt on this unique and first of a kind four-story structure constructed in the United States and implications for taller mass timber buildings are summarized and provide valuable insight for the design and assessment for this building type under future dynamic excitation events.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Ambient Vibration Measurement Data of a Four-Story Mass Timber Building
    Mugabo, Ignace
    Barbosa, Andre R.
    Riggio, Mariapaola
    Batti, James
    [J]. FRONTIERS IN BUILT ENVIRONMENT, 2019, 5
  • [2] Forced-Vibration Tests of a Reinforced Concrete Four-Story Building Structure
    De-la-Colina, Jaime
    Valdes-Gonzalez, Jesus
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (07)
  • [3] Fatigue Cracks Detection and Quantification in a Four-Story Building using a Nonlinear Index and Vibration Signals
    Yanez-Borjas, Jesus J.
    Camarena-Martinez, David
    Aguilera-Hernandez, Dulce, I
    Valtierra-Rodriguez, Martin
    Dominguez-Gonzalez, Aurelio
    Morales-Hernandez, Luis A.
    Perez-Ramirez, Carlos A.
    Amezquita-Sanchez, Juan P.
    [J]. PROCEEDINGS OF THE 2021 XXIII IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC 2021), 2021,
  • [4] An experimental case study of escooter fire in a four-story building
    Liu, X. Y.
    Ma, M. X.
    Wei, Z. L.
    Zhen, H. S.
    Wang, Y. L.
    [J]. JOURNAL OF FIRE SCIENCES, 2024,
  • [5] Investigation and Repair of a Four-Story Building Damaged by Yazoo Clay
    Maxwell, Britt
    [J]. JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2011, 25 (01) : 45 - 49
  • [6] Modal identification of a four-story reinforced concrete building under renovation by using ambient vibration measurement
    Areemit, N
    Yamaguchi, H
    Matsumoto, Y
    Ibi, T
    [J]. STRUCTURAL HEALTH MONITORING AND INTELLIGENT INFRASTRUCTURE, VOLS 1 AND 2, 2003, : 513 - 520
  • [7] Comparative analysis of the structural behavior of a four-story building with a fixed base and an isolated base
    Niquen, Katherine
    Villarreal, Genner
    Niquen, Vicente
    [J]. MEMORIA INVESTIGACIONES EN INGENIERIA, 2023, (25): : 107 - 136
  • [8] AMBIENT VIBRATION RECORDS IN REPRODUCING THE FORCED VIBRATION TEST RESULTS OF A FOUR-STORY REINFORCED CONCRETE BUILDING WITH TWO BASEMENT FLOORS
    Celik, Ozan Cem
    [J]. 6TH IOMAC: INTERNATIONAL OPERATIONAL MODAL ANALYSIS CONFERENCE PROCEEDINGS, 2015, : 513 - 519
  • [9] Seismic Response of a Four-Story Miniature Building with Replaceable Plastic Hinges
    Restrepo, Jose I.
    Rodriguez, Mario E.
    Kao-Stocker, Grace
    Carr, Athol J.
    [J]. JOURNAL OF EARTHQUAKE ENGINEERING, 2014, 18 (08) : 1217 - 1240
  • [10] Assessment of Retrofitting Techniques for a Four-Story Masonry Building to Resist Blast Loading
    Gouda, Ahmed
    Salem, Hamed
    Elansary, Ahmed
    [J]. JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2024, 38 (02)