Testing the effect of computer-assisted detection on interpretive performance in screening mammography

被引:39
|
作者
Taplin, Stephen H.
Rutter, Carolyn M.
Lehman, Constance D.
机构
[1] NCI, Appl Res Program, Div Canc Control & Populat Sci, Bethesda, MD 20892 USA
[2] Univ Washington, Seattle Canc Care Alliance, Dept Radiol, Seattle, WA 98109 USA
[3] Grp Hlth Cooperat Puget Sound, Ctr Hlth Studies, Seattle, WA 98101 USA
关键词
BI-RADS; breast cancer; computer-assisted detection; diagnosis; screening mammography;
D O I
10.2214/AJR.05.0940
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to test whether the use of computer-assisted detection (CAD) improves sensitivity at no cost to specificity for the detection of breast cancer and enables more accurate assessment of fatty breast tissue compared with dense breast tissue. MATERIALS AND METHODS. We created a stratified random sample of screening mammograms weighted with difficult cases split evenly among women with fatty breast tissue and those with dense breast tissue: 114 patients were cancer-free, 114 had cancer 1 year after screening, and 113 had cancer 13-24 months after screening. In test settings 6 months apart, 19 community radiologists interpreted 341 bilateral screening mammograms with and without CAD. We compared the sensitivity and specificity using regression models adjusting for repeated measures. RESULTS. CAD assistance did not affect overall sensitivity (cancer by 1 year: 63.2% without CAD and 62.0% with CAD; cancer in 13-24 months: 33.5% without CAD and 32.3% with CAD), but its effect differed for visible masses that were marked by CAD compared with those that were not marked by CAD (hereafter referred to as "unmarked"). CAD was associated with improved sensitivity for marked visible cancers and decreased sensitivity for unmarked visible masses; the sensitivities without and with CAD, respectively, were as follows: marked cancer by 1 year, 82.7% versus 83.1%; marked cancer in 13-24 months, 44.2% versus 57.9%; unmarked cancer by 1 year, 37.4% versus 30.1%; unmarked cancer in 13-24 months, 29.7% versus 23.0% (p < 0.03 for both interactions between assistance and CAD marking for cancer by 1 year and cancer in 13-24 months). CAD marked 77% (70/91) of the visible cancers by 1 year and 67.3% (37/55) of the visible cancers in 13-24 months. CAD marked more visible calcified lesions (86%) than masses and asymmetric densities (67%) (p < 0.05). Overall specificity was 72% without and 75% with CAD (p < 0.02). CAD had a greater effect on both specificity (p < 0.02) and sensitivity (p < 0.03) among radiologists who interpret more than 50 mammograms per week. The results were the same for fatty breast tissue and dense breast tissue. CONCLUSION. In this experiment, CAD increased interpretive specificity but did not affect sensitivity because visible noncalcified lesions that went unmarked by CAD were less likely to be assessed as abnormal by radiologists. Breast density did not affect CAD's performance.
引用
收藏
页码:1475 / 1482
页数:8
相关论文
共 50 条
  • [1] Is Computer-Assisted Detection the Standard of Care for Screening Mammography?
    Berlin, Leonard
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) : W533 - W533
  • [2] Computer-Assisted Detection and Screening Mammography: Where's the Beef?
    Berry, Donald A.
    [J]. JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2011, 103 (15) : 1139 - 1141
  • [3] Sensitivity and specificity of computer-assisted breast cancer detection in mammography screening
    Thurfjell, E
    Thurfjell, MG
    Egge, E
    Bjurstam, N
    [J]. ACTA RADIOLOGICA, 1998, 39 (04) : 384 - 388
  • [4] Computer-assisted diagnosis in mammography
    Gomez, S. M. Sanchez
    [J]. RADIOLOGIA, 2010, 52 : 14 - 17
  • [5] MAMMOGRAPHY AND COMPUTER-ASSISTED DIAGNOSIS
    GALE, AG
    ROEBUCK, EJ
    WORTHINGTON, BS
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (704): : 823 - 823
  • [6] Correlation of histological diagnosis and a computer-assisted detection system for mammography
    Wollenweber, T.
    Janke, B.
    Teichmann, A.
    Freund, M.
    [J]. GEBURTSHILFE UND FRAUENHEILKUNDE, 2007, 67 (02) : 135 - 141
  • [7] COMPUTER-ASSISTED DIAGNOSIS FOR DIGITAL MAMMOGRAPHY
    QIAN, W
    CLARKE, LP
    ZHENG, B
    KALLERGI, M
    CLARK, R
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1995, 14 (05): : 561 - 569
  • [8] COMPUTER-ASSISTED TESTING
    BURLI, A
    [J]. PSYCHOLOGIE-SCHWEIZERISCHE ZEITSCHRIFT FUR PSYCHOLOGIE UND IHRE ANDWENDUNGEN, 1973, 32 (01): : 26 - 45
  • [9] COMPUTER-ASSISTED TESTING
    DAVID, CW
    [J]. PHYSICS TODAY, 1983, 36 (04) : 94 - 94
  • [10] Virtual colonoscopy: effect of computer-assisted detection (CAD) on radiographer performance
    Burling, D.
    Moore, A.
    Marshall, M.
    Weldon, J.
    Gillen, C.
    Baldwin, R.
    Smith, K.
    Pickhardt, P.
    Honeyfield, L.
    Taylor, S.
    [J]. CLINICAL RADIOLOGY, 2008, 63 (05) : 549 - 556