Simultaneous quantitative trace analysis of anionic and nonionic surfactant mixtures by reversed-phase liquid chromatography

被引:24
|
作者
Portet, FI
Treiner, C
Desbène, PL
机构
[1] Univ Rouen, Lab Anal Syst Organ Complexes, UPRES EA 2659, IRCOF, F-27000 Evreux, France
[2] Univ Rouen, IFRMP, F-27000 Evreux, France
[3] Univ Paris 06, Lab Liquides Ion & Interfaces Chargees, UMR CNRS 7612, F-75005 Paris, France
关键词
factorial design; extraction methods; surfactants; poly(ethylene oxide); sodium dodecylsulphate;
D O I
10.1016/S0021-9673(00)00225-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of this work was to simultaneously analyse mixtures of a polydisperse polyethylene oxide (PEO) nonionic surfactant and an anionic surfactant (sodium dodecylsulphate, SDS) in water containing sodium chloride in order to quantify trace amounts of these mixtures after their adsorption at water-solid interfaces. A fractional factorial design was then used to optimise the separation by ion-pair reversed-phase liquid chromatography as a function of six factors: the chain length of the tetraalkylammonium salt used as ion-pairing reagent which varied from methyl (C-1) to n-propyl (C-3); the concentration of this ion-pairing salt; the acetonitrile percentage in water used as organic modifier; the flow-rate; the temperature of analysis and also the sodium chloride concentration. The factorial design enabled in a limited number of analyses, not only to determine which factors had significant effects on retention times or on resolution between a pair of nonionic oligomers, but also to modelize and then find the interesting and rugged area where this resolution was optimal as well as the conditions where time of analysis was not prohibitive, After optimisation of HPLC analysis, we used a trace enrichment procedure to quantify very low concentrations of SDS and C12E9 polydisperse PEO in water. A C-18 cartridge and a strong anionic exchange cartridge were coupled and the conditions of elution were optimised in order to obtain concentrated samples which were injected in the same eluent than the HPLC mobile phase. Under such conditions, we were able to quantify, in a single run, mixtures of anionic and nonionic surfactants at concentrations as low as 3.6 mu g l(-1) for SDS and 2.5 mu g l(-1) for each PEO oligomer in water. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:99 / 113
页数:15
相关论文
共 50 条
  • [1] Quantitative trace analysis of surfactant mixtures by reversed-phase high-performance liquid chromatography with refractometric detection
    Desbene, PL
    Portet, FI
    Goussot, GJ
    JOURNAL OF CHROMATOGRAPHY A, 1996, 730 (1-2) : 209 - 218
  • [2] QUANTITATIVE TRACE ANALYSIS BY REVERSED-PHASE LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    CHRISTENSEN, RG
    WHITE, E
    MEISELMAN, S
    HERTZ, HS
    JOURNAL OF CHROMATOGRAPHY, 1983, 271 (01): : 61 - 70
  • [3] Simultaneous analysis of clozapine, clomipramine and their metabolites by reversed-phase liquid chromatography
    Palego, L
    Dell'Osso, L
    Marazziti, D
    Biondi, L
    Sarno, N
    Ciapparelli, A
    Giromella, A
    Giannaccini, G
    Lucacchini, A
    Cassano, GB
    PROGRESS IN NEURO-PSYCHOPHARMACOLOGY & BIOLOGICAL PSYCHIATRY, 2001, 25 (03): : 519 - 533
  • [4] SIMULTANEOUS SEPARATION OF IONIC AND NONIONIC COMPOUNDS USING REVERSED-PHASE MICELLAR CHROMATOGRAPHY
    OKADA, T
    ANALYTICAL SCIENCES, 1993, 9 (01) : 59 - 64
  • [5] The effect of tween 80 nonionic surfactant on separation of barbiturates by reversed-phase high-performance liquid chromatography
    Rukhadze, MD
    Okudzhava, VM
    Makharadze, TG
    Rogava, MM
    ZHURNAL FIZICHESKOI KHIMII, 1998, 72 (05): : 952 - 954
  • [6] Quantitation of Compounds in Biodiesel Mixtures with Reversed-Phase Liquid Chromatography
    Santori, G.
    Arteconi, A.
    Di Nicola, G.
    Moglie, M.
    Stryjek, R.
    ENERGY & FUELS, 2009, 23 (07) : 3783 - 3789
  • [7] Simultaneous Determination of Mixtures of Nitrite and Nitrate by Reversed-Phase Ion-Pair Liquid Chromatography
    Qiu, Shiming
    Xi, Hongjuan
    Qing, Shaojun
    Hou, Xiaoning
    Gao, Zhixian
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2018, 65 (02) : 212 - 216
  • [8] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF ANIONIC AND ETHOXYLATED NONIONIC SURFACTANTS AND PESTICIDES IN LIQUID PESTICIDE FORMULATIONS
    BAN, T
    PAPP, E
    INCZEDY, J
    JOURNAL OF CHROMATOGRAPHY, 1992, 593 (1-2): : 227 - 231
  • [9] Quantitative analysis of forskolin in Coleus forskohlii (Lamiaceae) by reversed-phase liquid chromatography
    Schaneberg, BT
    Khan, IA
    JOURNAL OF AOAC INTERNATIONAL, 2003, 86 (03) : 467 - 470
  • [10] Quantitative analysis of flavonoids by reversed-phase high-performance liquid chromatography
    Crozier, A
    Jensen, E
    Lean, MEJ
    McDonald, MS
    JOURNAL OF CHROMATOGRAPHY A, 1997, 761 (1-2) : 315 - 321