Solid-state Cd/Cd2+ reference electrode based on PMMA gel electrolytes

被引:13
|
作者
Reiter, Jakub [1 ]
Vondrak, Jiri
Micka, Zdenek
机构
[1] Acad Sci Czech Republ, Inst Inorgan Chem, Rez 25068, Czech Republic
[2] Charles Univ Prague, Fac Sci, Prague 12840, Czech Republic
关键词
polymer gel electrolyte; cadmium; poly(methyl methacrylate); carbonate; reference electrode;
D O I
10.1016/j.ssi.2006.10.011
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
All solid-state reference electrode based on Cd/Cd2+ system was developed for the electrochemical measurements in aprotic organic carbonates (propylene PC, ethylene EC and dimethyl carbonate DMC). The electrode was designed by using poly(methyl methacrylate) - propylene carbonate polymer electrolyte with immobilised Cd(ClO4)(2) solution and a cadmium wire. The electrode performance in various solvents was studied including potential determination and its dependence on the solution ionic strength. Cyclic voltammetry of ferrocene in particular solvents showed good reproducibility of the electrode potential within the set of 18 electrodes: E(PMMA-Cd-Cd2+) = -0.439 +/- 0.013 vs. SCE in propylene carbonate. Also long-term chronopotentiometric measurements showed good potential stability and no potential drift within 3-week continuous experiment. Three versions of electrode material filling were studied (glass frit, ceramic separator and graphite rod) with the aim to reduce unwelcome penetration of chemicals into the electrode material and leakage of cadmium ions into solution. Reliable electrochemical data were obtained during the 5-year employment of the PMMA-Cd-Cd2+ electrode. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:3501 / 3506
页数:6
相关论文
共 50 条
  • [1] A SOLID-STATE MINIATURE REFERENCE ELECTRODE
    SMITH, RL
    SCOTT, DC
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (08) : 582 - 582
  • [2] CD2+/CD(HG) EXCHANGE IN ULTRA-PURIFIED ELECTROLYTES
    HAMPSON, NA
    LARKIN, D
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1968, 18 (04): : 401 - &
  • [3] Ionic gel effect on a reference electrode in a flexible solid-state pH sensor
    Pablo Tirado
    I. R. Chavez-Urbiola
    Jesus J. Alcantar-Peña
    MRS Communications, 2023, 13 : 41 - 46
  • [4] Ionic gel effect on a reference electrode in a flexible solid-state pH sensor
    Tirado, Pablo
    Chavez-Urbiola, I. R.
    Alcantar-Pena, Jesus J.
    MRS COMMUNICATIONS, 2023, 13 (01) : 41 - 46
  • [5] DETECTION OF ELECTROLYTES BASED ON SOLID-STATE ION-SELECTIVE ELECTRODE
    Chen, Li-Da
    Wang, Gou-Jen
    PROCEEDINGS OF ASME 2021 INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, IDETC-CIE2021, VOL 11, 2021,
  • [6] UPTAKE OF CD2+ AND OTHER DIVALENT-CATIONS BY CALCITE, SOLID-STATE DIFFUSION AND SOLID-SOLUTION FORMATION
    STIPP, SL
    HOCHELLA, MF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 178 - GEOC
  • [8] STANDARD POTENTIAL OF CDXHGY/CD2+ ELECTRODE
    CHOUDHARY, BK
    PRASAD, B
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 1973, 50 (02) : 153 - 154
  • [9] Promising new solid-state reference electrode
    Nagy, K
    Eine, K
    Syverud, K
    Aune, O
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1997, 144 (01) : L1 - L2
  • [10] CD spectra of solid-state samples
    Kuroda, R
    Honma, T
    CHIRALITY, 2000, 12 (04) : 269 - 277