Three-unit posterior zirconia-ceramic fixed dental prostheses (FDPs) veneered with layered and milled (CAD-on) veneering ceramics: 1-year follow-up of a randomized controlled clinical trial

被引:20
|
作者
Grohmann, Philipp [1 ]
Bindl, Andreas [2 ]
Haemmerle, Christoph [3 ]
Mehl, Albert [4 ]
Sailer, Irena [5 ]
机构
[1] Univ Zurich, Ctr Dent Med, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Reconstruct Dent, Zurich, Switzerland
[2] Univ Zurich, Ctr Dent Med, Clin Prevent Dent Periodontol & Cariol, Zurich, Switzerland
[3] Univ Zurich, Ctr Dent Med, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Zurich, Switzerland
[4] Univ Zurich, Ctr Dent Med, Clin Prevent Dent Periodontol & Cariol, Dept Computerized Dent, Zurich, Switzerland
[5] Univ Geneva, Ctr Dent & Oral Med, Div Fixed Prosthodont & Biomat, CH-1205 Geneva, Switzerland
来源
QUINTESSENCE INTERNATIONAL | 2015年 / 46卷 / 10期
关键词
CAD/CAM; CAD-on; fixed dental prosthesis; lithium disilicate; zirconia; LITHIUM-DISILICATE CROWNS; PARTIAL DENTURES; SURVIVAL RATES;
D O I
10.3290/j.qi.a34701
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The aim of this multicenter randomized controlled clinical trial was to test posterior zirconia-ceramic fixed dental prostheses (FDPs) veneered with a computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate veneering ceramic (CAD-on) and manually layered zirconia veneering ceramic with respect to survival of the FDPs, and technical and biologic outcomes. Method and Materials: Sixty patients in need of one posterior three-unit FDP were included. The zirconia frameworks were produced with a CAD/CAM system (Cerec inLab 3D/Cerec inEOS inLab). Thirty FDPs were veneered with a CAD/CAM lithium disilicate veneering ceramic (Cad-on) (test) and 30 were veneered with a layered zirconia veneering ceramic (control). For the clinical evaluation at baseline, 6, and 12 months, the United States Public Health Service (USPHS) criteria were used. The biologic outcome was judged by comparing the plaque control record (PCR), bleeding on probing (BOP), and probing pocket depth (PPD). Data were statistically analyzed. Results: Fifty-six patients were examined at a mean follow-up of 13.9 months. At the 1-year follow-up the survival rate was 100% in the test and in the control group. No significant differences of the technical outcomes occurred. Major chipping occurred in the control group (n = 3) and predominantly minor chipping in the test group (minor n = 2, major n = 1). No biologic problems or differences were found. Conclusions: Both types of zirconia-ceramic FDPs exhibited very good clinical outcomes without differences between groups. Chipping occurred in both types of FDPs at small amounts, yet the extension of the chippings differed. The test FDPs predominantly exhibited minor chipping, the control FDPs major chipping.
引用
收藏
页码:871 / 880
页数:10
相关论文
共 15 条
  • [1] A randomized controlled clinical trial of 3-unit posterior zirconia-ceramic fixed dental prostheses (FDP) with layered or pressed veneering ceramics: 3-year results
    Naenni, Nadja
    Bindl, Andreas
    Sax, Caroline
    Haemmerle, Christoph
    Sailer, Irena
    [J]. JOURNAL OF DENTISTRY, 2015, 43 (11) : 1365 - 1370
  • [2] Randomized Controlled Clinical Trial of Zirconia-Ceramic and Metal-Ceramic Posterior Fixed Dental Prostheses: A 3-year Follow-up
    Sailer, Irena
    Gottner, Jacqueline
    Kaenel, Sarah
    Haemmerle, Christoph Hans Franz
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2009, 22 (06) : 553 - 560
  • [3] Randomized clinical trial comparing monolithic and veneered zirconia three-unit posterior fixed partial dentures in a complete digital flow: three-year follow-up
    Paula Pontevedra
    Carlos Lopez-Suarez
    Veronica Rodriguez
    Jesus Pelaez
    Maria J. Suarez
    [J]. Clinical Oral Investigations, 2022, 26 : 4327 - 4335
  • [4] Randomized clinical trial comparing monolithic and veneered zirconia three-unit posterior fixed partial dentures in a complete digital flow: three-year follow-up
    Pontevedra, Paula
    Lopez-Suarez, Carlos
    Rodriguez, Veronica
    Pelaez, Jesus
    Suarez, Maria J.
    [J]. CLINICAL ORAL INVESTIGATIONS, 2022, 26 (06) : 4327 - 4335
  • [5] A Randomized Clinical Trial Comparing Zirconia and Metal-Ceramic Three-Unit Posterior Fixed Partial Dentures: A 5-Year Follow-Up
    Suarez, Maria J.
    Perez, Cristina
    Pelaez, Jesus
    Lopez-Suarez, Carlos
    Gonzalo, Esther
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (07): : 750 - 756
  • [6] Comparison of Metal-Ceramic and All-Ceramic Three-Unit Posterior Fixed Dental Prostheses: A 3-Year Randomized Clinical Trial
    Nicolaisen, Maj H.
    Bahrami, Golnosh
    Schropp, Lars
    Isidor, Flemming
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (03) : 259 - 264
  • [7] Fourteen-year evaluation of posterior zirconia-based three-unit fixed dental prostheses A Prospective clinical study of all ceramic prosthesis
    Zarone, Fernando
    Di Mauro, Maria Irene
    Spagnuolo, Gianrico
    Gherlone, Enrico
    Sorrentino, Roberto
    [J]. JOURNAL OF DENTISTRY, 2020, 101
  • [8] Clinical prospective evaluation of zirconia-based three-unit posterior fixed dental prostheses: Up-to ten-year results.
    Ioannidis, Alexis
    Bindl, Andreas
    [J]. JOURNAL OF DENTISTRY, 2016, 47 : 80 - 85
  • [9] A Randomized Clinical Trial Comparing the Clinical Fit of CAD/CAM Monolithic Zirconia Fixed Dental Prostheses on Ti-Base Abutments Based on Digital or Conventional Impression Techniques: 1-Year Follow-up
    Derksen, Wiebe
    Tahmaseb, Ali
    Wismeijer, Daniel
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (06) : 733 - 743
  • [10] Prospective Clinical Study of Zirconia-Based Posterior Four-Unit Fixed Dental Prostheses: Four-Year Follow-up
    Salido, Maria P.
    Martinez-Rus, Francisco
    del Rio, Fernando
    Pradies, Guillermo
    Oezcan, Mutlu
    Suarez, Maria J.
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (04) : 403 - 409