Energy consumption and energy-saving potential analysis of pollutant abatement systems in a 1000-MW coal-fired power plant

被引:9
|
作者
Yang, Hang [1 ]
Zhang, Yongxin [1 ]
Zheng, Chenghang [1 ]
Wu, Xuecheng [1 ]
Chen, Linghong [1 ]
Gao, Xiang [1 ]
Fu, Joshua S. [2 ]
机构
[1] Zhejiang Univ, State Key Lab Clean Energy Utilizat, Hangzhou, Zhejiang, Peoples R China
[2] Univ Tennessee, Dept Civil & Environm Engn, Knoxville, TN USA
关键词
EFFICIENCY INVESTMENTS; BARRIERS; INDUSTRY; PREDICTION; BUILDINGS; CLIMATE; SECTOR;
D O I
10.1080/10962247.2018.1454992
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pollutant abatement systems are widely applied in the coal-fired power sector, and the energy consumption is considered an important part of the auxiliary power. An energy consumption analysis and assessment model of pollutant abatement systems in a power unit was developed based on the dynamic parameters and technology. The energy consumption of pollutant abatement systems in a 1000-MW coal-fired power unit that meets the ultra-low emission limits and the factors of operating parameters, including unit load and inlet concentration of pollutants, on the operating power were analyzed. The results show that the total power consumption of the pollutant abatement systems accounted for 1.27% of the gross power generation during the monitoring period. The wet flue gas desulfurization (WFGD) system consumed 67% of the rate, whereas the selective catalytic reduction (SCR) and electrostatic precipitator (ESP) systems consumed 8.9% and 24.1%, respectively. The power consumption rate of pollutant abatement systems decreased with the increase of unit load and increased with the increase of the inlet concentration of pollutants. The operation adjustment was also an effective method to increase the energy efficiency. For example, the operation adjustment of slurry circulation pumps could promote the energy-saving operation of the WFGD system.Implications: The application of pollutant abatement technologies increases the internal energy consumption of the power plant, which will lead to an increase of power generation costs. The real-time energy consumption of the different pollutant abatement systems in a typical power unit is analyzed based on the dynamic operating data. Further, the influence of different operating parameters on the operating power of the system and the possible energy-saving potential are analyzed.
引用
收藏
页码:920 / 930
页数:11
相关论文
共 50 条
  • [2] Energy-saving and Optimization of Pulverizing System in Coal-fired Power Plant
    Li, Ji
    Wei, Jun
    Yang, Yongping
    [J]. RENEWABLE AND SUSTAINABLE ENERGY, PTS 1-7, 2012, 347-353 : 3151 - 3159
  • [3] Energy-saving and emission-abatement potential of Chinese coal-fired power enterprise: A non-parametric analysis
    Wei, Chu
    Loeschel, Andreas
    Liu, Bing
    [J]. ENERGY ECONOMICS, 2015, 49 : 33 - 43
  • [4] Energy-saving Analysis Based on the Specific Consumption Theory for Large Coal-fired Power Units
    Yang Yongping
    Yang Zhiping
    Yang Chenyao
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [5] Emergy analysis of energy-saving and emission reduction of coal-fired generation
    Li, Yonghua
    Wang, Jun
    Yan, Weiping
    [J]. ADVANCED RESEARCH ON INDUSTRY, INFORMATION SYSTEM AND MATERIAL ENGINEERING, 2012, 459 : 110 - 113
  • [6] Fuel Saving in Coal-fired Power Plant with Augmentation of Solar Energy
    Patel, Vivek
    Saha, Balaram
    Chatterjee, Kalyan
    [J]. 2014 INTERNATIONAL CONFERENCE ON POWER, CONTROL AND EMBEDDED SYSTEMS (ICPCES), 2014,
  • [7] THE OPERATING PARAMETERS SENSITIVE ANALYSIS OF ENERGY CONSUMPTION FOR COAL-FIRED POWER PLANT
    Wang, Hui-Jie
    Zhang, Chun-Fa
    Zhao, Ning
    [J]. PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON WAVELET ANALYSIS AND PATTERN RECOGNITION, VOLS 1 AND 2, 2008, : 862 - 867
  • [8] Tempospacial energy-saving effect-based diagnosis in large coal-fired power units: Energy-saving benchmark state
    Fu Peng
    Wang NingLing
    Yang YongPing
    Xu Han
    Li XiaoEn
    Zhang YuMeng
    [J]. SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2015, 58 (12) : 2025 - 2037
  • [9] Energy saving potential and system energy saving model of flue gas waste heat in coal-fired power plant boiler
    [J]. Duan, Aixia (dax0307@163.com), 1600, Italian Association of Chemical Engineering - AIDIC (62):
  • [10] Tempospacial energy-saving effect-based diagnosis in large coal-fired power units: Energy-saving benchmark state
    Peng Fu
    NingLing Wang
    YongPing Yang
    Han Xu
    XiaoEn Li
    YuMeng Zhang
    [J]. Science China Technological Sciences, 2015, 58 : 2025 - 2037