Paralleling of 3-phase 4-wire DC-AC Inverters Using Repetitive Control

被引:3
|
作者
Ainsworth, Nathan [1 ]
Murphree, Jerry [1 ]
机构
[1] DRS Test & Energy Management LLC, Huntsville, AL USA
关键词
D O I
10.1109/APEC.2009.4802642
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Constant frequency inverters, such as the 60Hz 120V UPS or the 208V 3-phase power system may be paralleled with the utility for backup power or paralleled with similar supplies to increase output capabilities. Previous research has addressed paralleling 3-phase 4-wire inverters. This paper will examine the parallel operation of 2 similar 3-phase 4-wire inverters using repetitive control. Repetitive control is a technique which takes advantage of the fixed frequency to reduce periodic disturbances. This type of control provides further benefits when paralleling supplies.
引用
收藏
页码:116 / 120
页数:5
相关论文
共 50 条
  • [1] H∞ control of the neutral point in 3-phase 4-wire DC-AC converters
    Zhong, QC
    Green, TC
    Liang, J
    Weiss, G
    IECON-2002: PROCEEDINGS OF THE 2002 28TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4, 2002, : 520 - 525
  • [2] ONE-KVA, 3-PHASE DC-AC INVERTER WITH DIGITAL CONTROL
    KNIGHT, MA
    TORKILDSEN, RA
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1969, AES5 (06) : 989 - +
  • [3] 3-PHASE 4-WIRE UNIMULTIGROUND DISTRIBUTION SYSTEM
    YEH, KC
    ELECTRICAL ENGINEERING IN JAPAN, 1966, 86 (09) : 52 - &
  • [4] New controllability criteria for 3-phase 4-wire inverters applied to shunt active power filters
    Perales, MA
    Terrón, L
    Sánchez, JA
    de la Torre, A
    Carrasco, JM
    Franquelo, LG
    IECON-2002: PROCEEDINGS OF THE 2002 28TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4, 2002, : 638 - 643
  • [5] Individual-phase control of 3-phase 4-wire voltage-source converter
    Fazeli, Seyed Mahdi
    Ping, Hew Wooi
    Bin Abd Rahim, Nasrudin
    Ooi, Boon Teck
    IET POWER ELECTRONICS, 2014, 7 (09) : 2354 - 2364
  • [6] The new concept for 3-phase 4-wire UPS system
    Hanaoka, Hiroyuki
    Matsuo, Hideaki
    Yanagisawa, Nanimi
    2015 IEEE INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2015,
  • [7] Dynamic Voltage Restoration in 3-Phase 4-Wire System
    Chlebis, Petr
    Odlevak, Lukas
    Hromjak, Michal
    Oplustil, Josef
    2013 INTERNATIONAL CONFERENCE ON APPLIED ELECTRONICS (AE), 2013, : 113 - 116
  • [8] Control of high performance DC-AC inverters using iterative learning control
    Wei, W
    Panda, SK
    Xu, JX
    TENCON 2004 - 2004 IEEE REGION 10 CONFERENCE, VOLS A-D, PROCEEDINGS: ANALOG AND DIGITAL TECHNIQUES IN ELECTRICAL ENGINEERING, 2004, : D132 - D135
  • [9] SagWave for the 3-Phase 4-Wire Voltage Sag Generator Prototype
    Oranpiroj, Kosol
    Premrudeeprechacharn, Suttichai
    Higuchi, Khoji
    2010 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, 2010, : 2209 - 2212
  • [10] POWER QUALITY IMPROVEMENT WITH UPQC IN 3-PHASE 4-WIRE SYSTEMS
    Kesler, Metin
    Ozdemir, Engin
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2010, 25 (04): : 681 - 691