Accuracy of Computed Tomography Attenuation Value of Lumbar Vertebra to Assess Bone Mineral Density

被引:3
|
作者
Chia, Kok King [1 ,2 ]
Haron, Juhara [1 ]
Malek, Nik Fatimah Salwati Nik [2 ]
机构
[1] Univ Sains Malaysia, Sch Med Sci, Dept Radiol, Kubang Kerian 1615O, Kelantan, Malaysia
[2] Hosp Sultanah Bahiyah, Dept Radiol, Alor Setar, Kedah, Malaysia
来源
MALAYSIAN JOURNAL OF MEDICAL SCIENCES | 2021年 / 28卷 / 01期
关键词
osteoporosis; post-menopausal bone loss; multidetector computed tomography; dual-energy X-ray absorptiometry; lumbar vertebrae; compression fracture; metabolic bone disease;
D O I
10.21315/mjms2021.28.1.6
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Computed tomography (CT) attenuation (Hounsfield unit [HU]) value of lumbar vertebra may provide an alternative method in the detection of osteoporosis during CT scans. Methods: A cross-sectional study on 50 patients of age 50 and above with contrast-enhanced CT (CECT) and dual-energy X-ray absorptiometry (DXA) was conducted from November 2018 to November 2019. Single region of interest (ROI) was placed at the anterior trabecular part of L1 vertebra on CELT to obtain HU value. Correlation of Cr HU value of L1 vertebra and DXA T-score, interrater reliability agreement between HU value of L1 vertebra and T-score in determining groups of with and without osteoporosis, ROC curve analysis for diagnostic accuracy and cut-off value of CT for detection of osteoporosis were identified. Results: Significant correlation between HU value of L1 vertebra and L1 T-score (r = 0.683)/lowest skeletal T-score (r = 0.703) (P < 0.001). Substantial agreement between HU value of L1 vertebra and DXA in determining the groups with and without osteoporosis (k = 0.8; P < 0.001). The area under the receiver operating characteristic (AUROC) curve was 0.93 (95% CI: 0.86, 1.00) using HU value (P < 0.001). Cut-off value for osteoporosis was 149 HU. Conclusion: HU value of lumbar vertebra is an effective alternative for the detection of osteoporosis with high diagnostic accuracy in hospitals without DXA facility.
引用
收藏
页码:41 / 50
页数:10
相关论文
共 50 条
  • [1] Bone Mineral Density Measurements of Lumbar Vertebrae by Quantitative Computed Tomography
    Riaz, Hassan
    Khan, Obaid Ullah
    Akram, Hamid
    RAWAL MEDICAL JOURNAL, 2009, 34 (01): : 4 - +
  • [2] Characterizing Bone Mineral Density Using Lumbar Spine Computed Tomography Attenuation in Patients With Distal Radius Fractures
    Ward, Christina M.
    Arnold, Mark A.
    Emohare, Osa
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2019, 10
  • [3] Assessment of the bone mineral density in the lumbar vertebrae of newborns by quantitative computed tomography
    Braillon, PM
    Lapillonne, A
    Ho, PS
    Bouvier, R
    Bochu, M
    Salle, BL
    SKELETAL RADIOLOGY, 1996, 25 (08) : 711 - 715
  • [4] Evaluation of bone mineral density after instrumented lumbar fusion with computed tomography
    Wanderman, Nathan
    Glassman, Steven D.
    Mkorombindo, Tino
    Dimar II, John R.
    Gum, Jeffrey L.
    Carreon, Leah Y.
    SPINE JOURNAL, 2022, 22 (06): : 951 - 956
  • [5] Hounsfield Units on Lumbar Computed Tomography for Predicting Regional Bone Mineral Density
    Kim, Kyung Joon
    Kim, Dong Hwan
    Lee, Jae Il
    Choi, Byung Kwan
    Han, In Ho
    Nam, Kyoung Hyup
    OPEN MEDICINE, 2019, 14 (01): : 545 - 551
  • [6] Fractional quantitative computed tomography for bone mineral density evaluation - Accuracy, precision, and comparison to quantitative computed tomography
    Lee, J
    Shin, HI
    Kim, SY
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (04) : 566 - 571
  • [7] Trabecular Bone Mineral Density Measurement Using Thoracic and Lumbar Quantitative Computed Tomography
    Budoff, Matthew J.
    Khairallah, Walid
    Li, Dong
    Gao, Yan Lin
    Ismaeel, Hussain
    Flores, Ferdinand
    Child, Janis
    Carson, Sivi
    Mao, Song Shou
    ACADEMIC RADIOLOGY, 2012, 19 (02) : 179 - 183
  • [8] Bone attenuation on chest computed tomography correlates with bone mineral density on densitometry in patients with emphysema and COPD
    Gutierrez, Jessica Gonzalez
    Ortega, Pilar Rivera
    Restituto, Patricia
    Varo, Nerea
    Colina, Inmaculada
    Calleja, Amparo
    Rodriguez, Macarena
    Mastarrika, Gorka
    Alcaide, Ana Belen
    Campo, Arantza
    Zulueta, Javier
    De Torres, Juan Pablo
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [9] Accuracy of Quantitative Computed Tomography Bone Mineral Density Measurements in Mandibles: A Cadaveric Study
    Miguel-Sanchez, Alfonso
    Vilaplana-Vivo, Jaime
    Vilaplana-Vivo, Carlos
    Angel Vilaplana-Gomez, Juan
    Camacho-Alonso, Fabio
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (04) : 693 - 699
  • [10] Accuracy of Opportunistic Bone Mineral Density Assessment on Staging Computed Tomography for Gynaecological Cancers
    O'Gorman, Catherine Anne
    Milne, Sarah
    Lambe, Gerard
    Sobota, Aleksandra
    Beddy, Peter
    Gleeson, Noreen
    MEDICINA-LITHUANIA, 2021, 57 (12):