Artificial Neural Network Algorithm for Online Glucose Prediction from Continuous Glucose Monitoring

被引:180
|
作者
Perez-Gandia, C. [1 ,2 ]
Facchinetti, A. [3 ]
Sparacino, G. [3 ]
Cobelli, C. [3 ]
Gomez, E. J. [2 ]
Rigla, M. [2 ,4 ]
de Leiva, A. [2 ,5 ]
Hernando, M. E. [2 ]
机构
[1] Univ Politecn Madrid, ETSI Telecomunicac, Grp Bioingn & Telemed, E-28040 Madrid, Spain
[2] Networking Res Ctr Bioengn Biomat & Nanomed CIBE, Madrid, Spain
[3] Univ Padua, Dipartimento Ingn Informaz, Padua, Italy
[4] Hosp Sabadell, Dept Endocrinol, Sabadell, Spain
[5] Hosp Santa Creu & Sant Pau, Dept Endocrinol, Barcelona, Spain
关键词
D O I
10.1089/dia.2009.0076
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Aims: Continuous glucose monitoring (CGM) devices could be useful for real-time management of diabetes therapy. In particular, CGM information could be used in real time to predict future glucose levels in order to prevent hypo-/hyperglycemic events. This article proposes a new online method for predicting future glucose concentration levels from CGM data. Methods: The predictor is implemented with an artificial neural network model (NNM). The inputs of the NNM are the values provided by the CGM sensor during the preceding 20 min, while the output is the prediction of glucose concentration at the chosen prediction horizon (PH) time. The method performance is assessed using datasets from two different CGM systems (nine subjects using the Medtronic [Northridge, CA] Guardian (R) and six subjects using the Abbott [Abbott Park, IL] Navigator (R)). Three different PHs are used: 15, 30, and 45 min. The NNM accuracy has been estimated by using the root mean square error (RMSE) and prediction delay. Results: The RMSE is around 10, 18, and 27mg/dL for 15, 30, and 45 min of PH, respectively. The prediction delay is around 4, 9, and 14 min for upward trends and 5, 15, and 26min for downward trends, respectively. A comparison with a previously published technique, based on an autoregressive model (ARM), has been performed. The comparison shows that the proposed NNM is more accurate than the ARM, with no significant deterioration in the prediction delay. Conclusions: The proposed NNM is a reliable solution for the online prediction of future glucose concentrations from CGM data.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 50 条
  • [1] Research of GPCEMBP Glucose Prediction Algorithm Based on Continuous Glucose Monitoring
    Cai, Lijun
    Ge, Wancheng
    Liu, Tingyu
    [J]. JOURNAL OF SENSORS, 2023, 2023
  • [2] Jump neural network for online short-time prediction of blood glucose from continuous monitoring sensors and meal information
    Zecchin, C.
    Facchinetti, A.
    Sparacino, G.
    Cobelli, C.
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2014, 113 (01) : 144 - 152
  • [3] Artificial Neural Network for Blood Glucose Level Prediction
    Hamdi, Takoua
    Ben Ali, Jaouher
    Fnaiech, Nader
    Di Costanzo, Veronique
    Fnaiech, Farhat
    Moreau, Eric
    Ginoux, Jean-Marc
    [J]. 2017 INTERNATIONAL CONFERENCE ON SMART, MONITORED AND CONTROLLED CITIES (SM2C), 2017, : 91 - 95
  • [4] A Review of Continuous Blood Glucose Monitoring and Prediction of Blood Glucose Level for Diabetes Type 1 Patient in Different Prediction Horizons (PH) Using Artificial Neural Network (ANN)
    Asad, Muhammad
    Qamar, Usman
    [J]. INTELLIGENT SYSTEMS AND APPLICATIONS, VOL 2, 2020, 1038 : 684 - 695
  • [5] Continuous blood glucose level prediction of Type 1 Diabetes based on Artificial Neural Network
    Ben Ali, Jaouher
    Hamdi, Takoua
    Fnaiech, Nader
    Di Costanzo, Veronique
    Fnaiech, Farhat
    Ginoux, Jean-Marc
    [J]. BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2018, 38 (04) : 828 - 840
  • [6] Glucose prediction from continuous subcutaneous monitoring data
    Maran, A
    Sparacino, G
    Pavanini, A
    Crepaldi, C
    Poscia, A
    Tiengo, A
    Avogaro, A
    Cobelli, C
    [J]. DIABETES, 2004, 53 : A105 - A105
  • [7] From insulin pump and continuous glucose monitoring to the artificial pancreas
    Apablaza, Pamela
    Soto, Nestor
    Codner, Ethel
    [J]. REVISTA MEDICA DE CHILE, 2017, 145 (05) : 630 - 640
  • [8] Artificial intelligence biosensors for continuous glucose monitoring
    Jin, Xiaofeng
    Cai, Andrew
    Xu, Tailin
    Zhang, Xueji
    [J]. INTERDISCIPLINARY MATERIALS, 2023, 2 (02): : 290 - 307
  • [9] A New Neural Network Approach for Short-Term Glucose Prediction Using Continuous Glucose Monitoring Time-Series and Meal Information
    Zecchin, C.
    Facchinetti, A.
    Sparacino, G.
    De Nicolao, G.
    Cobelli, C.
    [J]. 2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 5653 - 5656
  • [10] Enhanced Algorithm for glucose estimation using the Continuous Glucose Monitoring System
    Leal, Yenny
    Garcia-Gabin, Winston
    Bondia, Jorge
    Esteve, Eduardo
    Ricart, Wifredo
    Fernandez-Real, Jose-Manuel
    Vehi, Josep
    [J]. MEDICAL SCIENCE MONITOR, 2010, 16 (06): : MT51 - MT58