Capillary liquid chromatography using a hydrophilic/cation-exchange monolithic column with a dynamically modified cationic surfactant

被引:13
|
作者
Lin, Jian [1 ]
Lin, Jia [1 ]
Lin, Xucong [1 ]
Xie, Zenghong [1 ]
机构
[1] Fuzhou Univ, Dept Chem, Fuzhou 350002, Peoples R China
关键词
Monolithic stationary phases; Dynamically modified capillary liquid chromatography; Hydrophilic interaction; Reversed-phase mode; REVERSED-PHASE; MASS-SPECTROMETRY; SILICA MONOLITHS; SEPARATION; ELECTROCHROMATOGRAPHY; TECHNOLOGY; MODE;
D O I
10.1016/j.chroma.2009.08.071
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel form of reversed-phase liquid chromatography (RPLC) by the dynamically modified hydrophilic interaction monolithic column has been described in this paper. A porous poly(SPMA-co-PETA) monolith with strong cation-exchange (SCX) was prepared and the resulting monolith showed a typical hydrophilic interaction chromatography (HILIC) mechanism at higher organic solvent content (ACN% > 50%). The good selectivity for neutral, basic and acidic polar analytes was observed in the HILIC mode. In order to increase the hydrophobic interaction, the monolith with SCX was dynamically modified with a long-chain quaternary ammonium salt, cetyltrimethylammonium bromide (CTAB), which was added to the mobile phase. CTAB ions were adsorbed onto the surface of the SCX monolithic material, and the resulting hydrophobic layer was used as the stationary phase. Using the dynamically modified SCX monolithic column, neutral, basic and acidic hydrophobic analytes were well separated with the RPLC mode. Crown Copyright (C) 2009 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:7728 / 7731
页数:4
相关论文
共 50 条
  • [1] Capillary electrochromatography using a strong cation-exchange column with a dynamically modified cationic surfactant
    Ye, ML
    Zou, HF
    Liu, Z
    Ni, JY
    Zhang, YK
    ANALYTICAL CHEMISTRY, 2000, 72 (03) : 616 - 621
  • [2] Weak cation-exchange monolithic column for capillary liquid chromatography of peptides and proteins
    Chen, Xin
    Tolley, H. Dennis
    Lee, Milton L.
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (16-17) : 2063 - 2071
  • [3] Polymeric strong cation-exchange monolithic column for capillary liquid chromatography of peptides and proteins
    Chen, Xin
    Tolley, H. Dennis
    Lee, Milton L.
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (15-16) : 2565 - 2573
  • [4] Preparation and Application of Cation-exchange Capillary Monolithic Column in Capillary Ion Chromatography
    Li Jing
    Zhu Yan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (03) : 400 - 405
  • [5] Capillary electrochromatography with a silica column with a dynamically modified cationic surfactant
    Ye, ML
    Zou, HF
    Liu, Z
    Ni, JY
    Zhang, YK
    JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) : 137 - 145
  • [6] Silica-supported polymeric monolithic column with a mixed mode of hydrophilic and strong cation-exchange interactions for microcolumn liquid chromatography
    Ren, Hang
    Zhang, Xinyue
    Li, Zhen
    Liu, Zhaobin
    Li, Jinxiang
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (04) : 826 - 833
  • [7] Separation of proteins by cation-exchange sequential injection chromatography using a polymeric monolithic column
    Masini, Jorge Cesar
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (05) : 1445 - 1452
  • [8] Separation of proteins by cation-exchange sequential injection chromatography using a polymeric monolithic column
    Jorge Cesar Masini
    Analytical and Bioanalytical Chemistry, 2016, 408 : 1445 - 1452
  • [9] Monolithic column with double mixed-modes of hydrophilic interaction/cation-exchange and reverse-phase/cation-exchange stationary phase for pressurized capillary electrochromatography
    Wang, Jiabin
    Lue, Haixia
    Lin, Xucong
    Xie, Zenghong
    ELECTROPHORESIS, 2008, 29 (04) : 928 - 935
  • [10] Hydrophilic interaction/cation-exchange chromatography for glycopeptide enrichment by using a modified strong-cation exchange material
    Chen, Linlin
    Dong, Xuefang
    Cao, Liwei
    Guo, Zhimou
    Yu, Long
    Zou, Lijuan
    Liang, Xinmiao
    ANALYTICAL METHODS, 2013, 5 (24) : 6919 - 6924