Quantitative pulmonary blood flow measurement using 15O-H2O PET with and without tissue fraction correction: a comparison study

被引:6
|
作者
Matsunaga, Keiko [1 ,2 ]
Yanagawa, Masahiro [3 ]
Otsuka, Tomoyuki [4 ]
Hirata, Haruhiko [4 ]
Kijima, Takashi [4 ]
Kumanogoh, Atsushi [4 ]
Tomiyama, Noriyuki [3 ]
Shimosegawa, Eku [1 ,2 ]
Hatazawa, Jun [2 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Mol Imaging Med, Suita, Osaka, Japan
[2] Osaka Univ, Grad Sch Med, Dept Nucl Med & Tracer Kinet, 2-2 Yamadaoka, Suita, Osaka, Japan
[3] Osaka Univ, Grad Sch Med, Diagnost & Intervent Radiol, Suita, Osaka, Japan
[4] Osaka Univ, Grad Sch Med, Dept Resp Med Allergy & Rheumat Dis, Suita, Osaka, Japan
来源
EJNMMI RESEARCH | 2017年 / 7卷
关键词
PET; O-15-H2O; Pulmonary blood flow; Tissue fraction correction; REGIONAL LUNG DENSITY; POSITRON EMISSION; COPD; MORPHOMETRY; TOMOGRAPHY;
D O I
10.1186/s13550-017-0350-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Physiological measures per lung parenchyma, rather than per lung volume, sometimes reflect the disease status. PET images of the lung, which are usually expressed per lung volume, could confound the interpretation of the disease status, especially in cases with a prominent heterogeneity in aeration. The aim of the present study was to develop a method for measuring pulmonary blood flow (PBF) with aeration correction using O-15-H2O PET and to compare the results with those obtained using a conventional method. We obtained the voxel-based tissue fraction (TF) derived from density images converted from transmission images obtained using an external Cs-137 point source. Quantitative PBF values with and without the TF were calculated using O-15-H2O PET to examine contralateral lung tissue in 9 patients with unilateral lung cancer. The heterogeneity in PBF before and after TF correction was then evaluated and compared. As a measure of PBF heterogeneity, we used the skewness and kurtosis of the PBF distribution. Results: The mean PBF of contralateral lung was 1.4 +/- 0.3 mL/min per mL of lung. The TF-corrected PBF was 5.0 +/- 0.6 mL/min per mL of lung parenchyma. After TF correction, the skewness and kurtosis of the PBF decreased significantly. Conclusions: The present PBF calculation method using TF correction demonstrated that the normal PBF increased significantly and the PBF distribution became uniform. The proposed TF correction method is a promising technique to account for variations in density when interpreting PBF in PET studies.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Quantitative pulmonary blood flow measurement using 15O-H2O PET with and without tissue fraction correction: a comparison study
    Keiko Matsunaga
    Masahiro Yanagawa
    Tomoyuki Otsuka
    Haruhiko Hirata
    Takashi Kijima
    Atsushi Kumanogoh
    Noriyuki Tomiyama
    Eku Shimosegawa
    Jun Hatazawa
    EJNMMI Research, 7
  • [2] Pulmonary perfusion measured by 15O-H2O PET with and without a correction for tissue fraction
    Matsunaga, Keiko
    Yanagawa, Masahiro
    Watabe, Hiroshi
    Fujino, Kouichi
    Kato, Hiroki
    Shimosegawa, Eku
    Hatazawa, Jun
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [3] Comparison of electrocardiogram synchronization and asynchronization in myocardial blood flow measurement with 15O-H2O PET
    Kato, Shinya
    Aikawa, Tadao
    Naya, Masanao
    Magota, Keiichi
    Manabe, Osamu
    Kawauchi, Keisuke
    Katoh, Chietsugu
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [4] Effects of motion correction on quantification of myocardial blood flow with 15O-H2O PET
    Koshino, K
    Kawachi, N
    Hayashi, T
    Watabe, H
    Hasegawa, S
    Hatazawa, J
    Iida, H
    QUANTITATION IN BIOMEDICAL IMAGING WITH PET AND MRI, 2004, (1265): : 106 - 110
  • [5] Improved spillover correction model to quantify myocardial blood flow by 11C-acetate PET: comparison with 15O-H2O PET
    Yuki Mori
    Osamu Manabe
    Masanao Naya
    Yuuki Tomiyama
    Keiichiro Yoshinaga
    Keiichi Magota
    Noriko Oyama-Manabe
    Kenji Hirata
    Hiroyuki Tsutsui
    Nagara Tamaki
    Chietsugu Katoh
    Annals of Nuclear Medicine, 2015, 29 : 15 - 20
  • [6] Improved spillover correction model to quantify myocardial blood flow by 11C-acetate PET: comparison with 15O-H2O PET
    Mori, Yuki
    Manabe, Osamu
    Naya, Masanao
    Tomiyama, Yuuki
    Yoshinaga, Keiichiro
    Magota, Keiichi
    Oyama-Manabe, Noriko
    Hirata, Kenji
    Tsutsui, Hiroyuki
    Tamaki, Nagara
    Katoh, Chietsugu
    ANNALS OF NUCLEAR MEDICINE, 2015, 29 (01) : 15 - 20
  • [7] Quantification of myocardial blood flow with 11C-hydroxyephedrine dynamic PET: comparison with 15O-H2O PET
    Hiroshima, Yuji
    Manabe, Osamu
    Naya, Masanao
    Tomiyama, Yuuki
    Magota, Keiichi
    Obara, Masahiko
    Aikawa, Tadao
    Oyama-Manabe, Noriko
    Yoshinaga, Keiichiro
    Hirata, Kenji
    Kroenke, Markus
    Tamaki, Nagara
    Katoh, Chietsugu
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (04) : 1118 - 1125
  • [8] Quantification of Myocardial blood flow with 11C-hydroxyephedrine Dynamic PET: comparison with 15O-H2O PET
    Hiroshima, Yuji
    Manabe, Osamu
    Naya, Masanao
    Aikawa, Tadao
    Obara, Masahiko
    Yoshinaga, Keiichiro
    Tomiyama, Yuuki
    Magota, Keiichi
    Tamaki, Nagara
    Katoh, Chietsugu
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [9] Quantification of myocardial blood flow with 11C-hydroxyephedrine dynamic PET: comparison with 15O-H2O PET
    Yuji Hiroshima
    Osamu Manabe
    Masanao Naya
    Yuuki Tomiyama
    Keiichi Magota
    Masahiko Obara
    Tadao Aikawa
    Noriko Oyama-Manabe
    Keiichiro Yoshinaga
    Kenji Hirata
    Markus Kroenke
    Nagara Tamaki
    Chietsugu Katoh
    Journal of Nuclear Cardiology, 2020, 27 : 1118 - 1125
  • [10] Improvement of method for quantification of regional myocardial blood flow using 11C-acetate PET: Comparison with 15O-H2O PET
    Mori, Yuki
    Katoh, Chietsugu
    Naya, Masanao
    Manabe, Osamu
    Yoshinaga, Keiichiro
    Tomiyama, Yuuki
    Tamaki, Nagara
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54