Results of aortic valve replacement with pulmonary and aortic homografts

被引:0
|
作者
Naegele, H [1 ]
Bohlmann, M [1 ]
Döring, V [1 ]
Kalmar, P [1 ]
Rödiger, W [1 ]
机构
[1] Univ Clin Hamburg Eppendorf, Dept Cardiovasc & Vasc Surg, Hamburg, Germany
来源
JOURNAL OF HEART VALVE DISEASE | 2000年 / 9卷 / 02期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: Aortic valve replacement with cryopreserved human pulmonary or aortic valves (homografts) is an attractive alternative to the implantation of mechanical valves or bioprostheses, as anticoagulation can be avoided and a near-normal anatomy restored. However, few reports exist on the long-term follow up of patients with this type of valve. Methods: Between 1990 and 1997, a total of 64 homografts were implanted in 62 adults (mean age 42 +/- 12 years) with non-endocarditic valve lesions (insufficiency, n = 16; stenosis, n = 20; combined lesions, n = 12; redo, n = 16). In total, 23 pulmonary grafts (PG) and 41 aortic grafts (AG) were used. Valves were obtained from the European Homograft Bank in Brussels. Two patients with aortic homografts were lost to follow up; the others were examined clinically and echocardiographically at yearly intervals (mean 3.6 +/- 2.0 years). Children aged less than 16 years (n = 21), and patients receiving a homograft due to endocarditis (n = 28) or during a Ross procedure (n = 16) were excluded from the study. Results: Three patients (5%) died due to early postoperative complications (two with AG, one with PG). Three PG had to be explanted due to primary malfunction, and five (total 35%) during further follow up due to severe aortic insufficiency (at a mean of 3.3 +/- 1.8 years). In contrast, all AG were functioning at the end of the observation period (log rank test, p = 0.0001, chi-square test 13.9). The mean echocardiographic degree of regurgitation for PG was significantly higher than for AG (2.2 +/- 1 vs. 0.75 +/- 0.7, p <0.0001). The peak transvalvular gradient did not differ between groups (FG 12.3 +/- 9 mmHg vs. AG 16.7 +/- 10 mmHg, p = NS). In respect of perioperative parameters, patients with FG showed a significantly higher body temperature during the first seven postoperative days (37.3 +/- 0.6 degrees C vs. 36.8 +/- 0.3 degrees C, p = 0.003). All three patients with acute graft malfunction in long-term follow up had a perioperative febrile response without overt bacterial infection. Conclusion: In contrast to grafts of aortic origin, pulmonary homograft valves should not be used for aortic valve replacement because of their high rate of malfunction, both acutely and chronically. Higher postoperative body temperatures should lead to further investigations of possible enhanced immunoreactions against pulmonary homografts.
引用
收藏
页码:215 / 220
页数:6
相关论文
共 50 条
  • [1] Results of aortic valve replacement with pulmonary and aortic homografts - Discussion
    Bodnar, E
    Kalmar, P
    Gamba, A
    David, T
    Vesely, I
    JOURNAL OF HEART VALVE DISEASE, 2000, 9 (02): : 220 - 221
  • [2] USE OF AORTIC VALVE HOMOGRAFTS FOR AORTIC VALVE REPLACEMENT
    WALLACE, RB
    GIULIANI, ER
    TITUS, JL
    CIRCULATION, 1971, 43 (03) : 365 - &
  • [3] RESULTS OF AORTIC VALVE REPLACEMENT UTILIZING IRRADIATED VALVE HOMOGRAFTS
    MALM, JR
    BOWMAN, FO
    HARRIS, PD
    KAISER, GA
    KOVALIK, ATW
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1969, 147 (A18) : 740 - &
  • [4] Midterm Results of Aortic Valve Replacement with Cryopreserved Homografts
    Vuran, Can
    Simon, Paul
    Wollenek, Gregor
    Ozker, Emre
    Aslim, Erdal
    BALKAN MEDICAL JOURNAL, 2012, 29 (02) : 170 - 173
  • [5] Mitral and aortic valve replacement using fresh unstented pulmonary and aortic homografts
    Ozdogan, ME
    Oktar, L
    Gunaydin, S
    Halit, V
    Sinav, A
    Yener, A
    Ersoz, A
    JOURNAL OF HEART VALVE DISEASE, 1996, 5 (02): : 181 - 185
  • [6] AORTIC-VALVE REPLACEMENT WITH PULMONARY HOMOGRAFTS - EARLY EXPERIENCE
    GEROSA, G
    ROSS, DN
    BRUCKE, PE
    DZIATKOWIAK, A
    MOHAMMAD, S
    NORMAN, D
    DAVIES, J
    SBARBATI, A
    CASAROTTO, D
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 107 (02): : 424 - 437
  • [7] AORTIC HOMOGRAFTS FOR HETEROTOPIC VALVE REPLACEMENT
    ANGELL, WW
    WUERFLEI.RD
    STINSON, EB
    SHUMWAY, NE
    CIRCULATION, 1968, 38 (4S6) : VI34 - &
  • [8] Exercise after aortic valve replacement: Comparison of pulmonary autografts versus aortic homografts
    Laforest, I
    Pibarot, P
    Briand, M
    Cartier, PC
    Dumesnil, JGG
    CIRCULATION, 2001, 104 (17) : 760 - 760
  • [9] TRIPLE VALVE REPLACEMENT WITH AORTIC HOMOGRAFTS
    STINSON, EB
    ANGELL, WW
    SHUMWAY, NE
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1968, 204 (01): : 67 - &
  • [10] HOMOGRAFTS FOR REPLACEMENT OF AORTIC-VALVE
    PACIFICO, AD
    KARP, RB
    KIRKLIN, JW
    CIRCULATION, 1972, 45 (05) : I36 - &