Hemodynamic effects of pulsatile unloading of left ventricular assist devices (LVAD) on intraventricular flow and ventricular stress

被引:1
|
作者
Gu, Kaiyun [1 ,2 ]
Guan, Zhiyuan [1 ]
Chang, Yu [3 ]
Gao, Bin [3 ]
Ling, Yunpeng [1 ]
Song, Zhiming [2 ]
Wan, Feng [2 ]
机构
[1] Peking Univ, Hosp 3, 49 North Garden Rd, Beijing 100191, Peoples R China
[2] Toni Univ, Shanghai East Hosp, Dept Cardiac Surg, Sch Med, 150 Jimo Rd, Shanghai 200210, Peoples R China
[3] Beijing Univ Technol, Coll Life Sci & Bioengn, 100 Pingleyuan, Beijing 100124, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Pulsatile unloading; Left ventricular assist devices; Intraventricular flow; Ventricular stress; AORTIC-INSUFFICIENCY; CARDIOGENIC-SHOCK; SUPPORT; MODELS; HEART; MYOCARDIUM;
D O I
10.1016/j.jbiomech.2019.109425
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The role of pulsatile unloading in hemodynamic changes in intraventricular flow and ventricular wall stress remains unknown. In this study, a finite element model of the left ventricle (LV) is proposed to calculate the mechanical response. The constitutive model of the LV is composed of a quasi-incompressible transversely isotropic model and an active contraction of the myocardium model. Pulsatile unloading is provided by the left ventricular assist device (LVAD), which is implanted between the aortic root and aortic arch. Support models (constant speed and co-pulse) were utilized to study the effect of pulsatile unloading on intraventricular flow and ventricular stress. The result indicates that the formation time of the vortex increases under pulsatile unloading. The area rate of high time-averaged wall shear stress (TAWSS) increased after pulsatile unloading. The area of the high oscillatory shear index (OSI) region (OSI > 0.375) was calculated for heart failure, constant speed, and co-pulse (9.9 cm(2), 9.6 cm(2), and 9.2 cm(2), respectively). The maximum value of the stress that reflects the level of stretch declined after pulsatile unloading (66.4 kPa, 30.9 kPa, and 21.3 kPa, respectively). Besides, pulsatile unloading impacts the maximum value of thickness at the ventricular wall (-0.75 mm, -1 mm, and -1.25 mm, respectively). The change ratios of the thickness are 10%, 14%, and 17%, respectively. In conclusion, pulsatile unloading contributes to the distribution of intraventricular flow and the formation time of the vortex. Co-pulse support significantly reduces the maximum value of the ventricular wall stress and the area of high stress on the ventricular wall. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Effects of pulsatile- and continuous-flow left ventricular assist devices on left ventricular unloading
    Garcia, Santiago
    Kandar, Forum
    Boyle, Andrew
    Colvin-Adams, Monica
    Lliao, Kenneth
    Joyce, Lyle
    John, Ranjit
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (03): : 261 - 267
  • [2] Serial Assessment of Pulsatile and Non-Pulsatile Left Ventricular Assist Devices on Left Ventricular Unloading
    George, Robert S.
    Yacoub, Magdi H.
    Webb, Carole
    Bowles, Christopher
    Dean, Robert
    Hedger, Mike
    Dreyfus, Giles
    Khaghani, Asghar
    Birks, Emma J.
    [J]. CIRCULATION, 2008, 118 (18) : S1016 - S1016
  • [3] Hemodynamic Effects of Pacing in Patients with Durable Left Ventricular Assist Devices (LVAD)
    Akdogan, R. E.
    Kozaily, E.
    Rofael, M.
    Fu, S.
    Silverman, D.
    Atkins, J.
    Inampudi, C.
    Jackson, G.
    Griffin, J. M.
    Rao, V.
    Hajj, J.
    Witer, L.
    Kilic, A.
    Houston, B.
    Tedford, R.
    Carnicelli, A.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2024, 43 (04): : S391 - S391
  • [4] The Effects of Hemodynamic Unloading in African Americans Implanted with Left Ventricular Assist Devices
    Tehrani, David M.
    Rodgers, Daniel
    Adatya, Sirtaz
    Sarswat, Nitasha
    Raikhelkar, Jayant
    Kim, Gene H.
    Sayer, Gabriel
    Uriel, Nir
    [J]. ASAIO JOURNAL, 2019, 65 (02) : E15 - E17
  • [5] Hemodynamic and exercise performance with Pulsatile and continuous-flow left ventricular assist devices
    Haft, Jonathan
    Armstrong, William
    Dyke, David B.
    Aaronson, Keith D.
    Koelling, Todd M.
    Farrar, David J.
    Pagani, Francis D.
    [J]. CIRCULATION, 2007, 116 (11) : I8 - I15
  • [6] HEMODYNAMIC EVALUATION OF PULSATILE-FLOW GENERATING DEVICE IN LEFT VENTRICULAR ASSIST DEVICES
    Buchnev, A. S.
    Kuleshov, A. P.
    Esipova, O. Yu
    Drobyshev, A. A.
    Grudinin, N., V
    [J]. VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2023, 25 (01): : 106 - 112
  • [7] Effects of Continuous-Flow Versus Pulsatile-Flow Left Ventricular Assist Devices on Myocardial Unloading and Remodeling
    Kato, Tomoko S.
    Chokshi, Aalap
    Singh, Parvati
    Khawaja, Tuba
    Cheema, Faisal
    Akashi, Hirokazu
    Shahzad, Khurram
    Iwata, Shinichi
    Homma, Shunichi
    Takayama, Hiroo
    Naka, Yoshifumi
    Jorde, Ulrich
    Farr, Maryjane
    Mancini, Donna M.
    Schulze, P. Christian
    [J]. CIRCULATION-HEART FAILURE, 2011, 4 (05) : 546 - U34
  • [8] Left Ventricular (LV) Response to Unloading by Continuous-flow Left Ventricular Assist Devices (LVAD): Axial Vs. Centrifugal?
    Rauf, A.
    Johnson, A. K.
    Wright, G. A.
    Stoker, S.
    Reid, B. B.
    Caine, W. T.
    Goddard, M. K.
    Alharethi, R.
    Thomsen, G. E.
    Budge, D.
    Clayson, S. E.
    Rasmusson, B. Y.
    Kfoury, A. G.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04): : S155 - S155
  • [9] Comparison of the effects of continuous and pulsatile left ventricular-assist devices on ventricular unloading using a cardiac electromechanics model
    Lim, Ki Moo
    Constantino, Jason
    Gurev, Viatcheslav
    Zhu, Renjun
    Shim, Eun Bo
    Trayanova, Natalia A.
    [J]. JOURNAL OF PHYSIOLOGICAL SCIENCES, 2012, 62 (01): : 11 - 19
  • [10] Comparison of the effects of continuous and pulsatile left ventricular-assist devices on ventricular unloading using a cardiac electromechanics model
    Ki Moo Lim
    Jason Constantino
    Viatcheslav Gurev
    Renjun Zhu
    Eun Bo Shim
    Natalia A. Trayanova
    [J]. The Journal of Physiological Sciences, 2012, 62 : 11 - 19