Evaluation of platelet function in dogs with cardiac disease using the PFA-100 platelet function analyzer

被引:9
|
作者
Clancey, Noel [1 ]
Burton, Shelley [1 ]
Horney, Barbara [1 ]
MacKenzie, Allan [1 ]
Nicastro, Andrea [1 ]
Cote, Etienne [1 ]
机构
[1] Univ Prince Edward Isl, Dept Pathol & Microbiol, Atlantic Vet Coll, Charlottetown, PE C1A 4P3, Canada
关键词
Canine; cardiac; PFA-100; platelet; MUCOSA BLEEDING TIMES; ACETYLSALICYLIC-ACID; SODIUM-CITRATE; HEALTHY DOGS; AGGREGATION; HEMATOCRIT;
D O I
10.1111/j.1939-165X.2009.00138.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Cardiac disease has the potential to alter platelet function in dogs. Evaluation of platelet function using the PFA-100 analyzer in dogs of multiple breeds and with a broad range of cardiac conditions would help clarify the effect of cardiac disease on platelets. Objectives The objective of this study was to assess differences in closure time (CT) in dogs with cardiac disease associated with murmurs, when compared with that of healthy dogs. Methods Thirty-nine dogs with cardiac murmurs and turbulent blood flow as determined echocardiographically were included in the study. The dogs represented 23 different breeds. Dogs with murmurs were further divided into those with atrioventricular valvular insufficiency (n=23) and subaortic stenosis (n=9). Fifty-eight clinically healthy dogs were used as controls. CTs were determined in duplicate on a PFA-100 analyzer using collagen/ADP cartridges. Results Compared with CTs in the control group (mean +/- SD, 57.6 +/- 5.9 seconds; median, 56.5 seconds; reference interval, 48.0-77.0 seconds), dogs with valvular insufficiency (mean +/- SD, 81.9 +/- 26.3 seconds; median, 78.0 seconds; range, 52.5-187 seconds), subaortic stenosis (71.4 +/- 16.5 seconds; median, 66.0 seconds; range, 51.5-95.0 seconds), and all dogs with murmurs combined (79.6 +/- 24.1 seconds; median, 74.0 seconds; range, 48.0-187 seconds) had significantly prolonged CTs (P <.01). Conclusions The PFA-100 analyzer is useful in detecting platelet function defects in dogs with cardiac murmurs, most notably those caused by mitral and/or tricuspid valvular insufficiency or subaortic stenosis. The form of turbulent blood flow does not appear to be an important factor in platelet hypofunction in these forms of cardiac disease.
引用
收藏
页码:299 / 305
页数:7
相关论文
共 50 条
  • [1] Clinical evaluation of platelet function analyzer PFA-100 in dogs
    Keidel, A
    Mischke, R
    [J]. BERLINER UND MUNCHENER TIERARZTLICHE WOCHENSCHRIFT, 1998, 111 (11-12): : 452 - 456
  • [2] Evaluation of platelet function in the parturient using the platelet function analyzer (PFA-100®).
    Nair, A
    Arnold, I
    Goolie-Scindain, J
    Bodian, CA
    Hossain, S
    Beilin, Y
    [J]. ANESTHESIOLOGY, 2001, 94 (1A) : U30 - U30
  • [3] EVALUATION OF PLATELET FUNCTION DURING PREGNANCY USING THE PLATELET FUNCTION ANALYZER (PFA-100)
    Kousoulakou, A.
    Perdiou, A.
    Papadopoulou, G.
    Leveta, G.
    Trigka, A.
    Statherou, K.
    Andromida, M.
    Tsoukanas, V.
    [J]. HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2009, 94 : 530 - 530
  • [4] Evaluation of the hemostatic function of stored platelet concentrates using the platelet function analyzer (PFA-100™)
    Borzini, P
    Lazzaro, A
    Mazzucco, L
    [J]. HAEMATOLOGICA, 1999, 84 (12) : 1104 - 1109
  • [5] Evaluation of platelet function in a pediatric setting using the platelet function analyzer (PFA-100(TM))
    Carcao, MD
    Dean, J
    He, L
    Stain, AM
    Sparling, CR
    Christensen, H
    Freedman, J
    Balanchette, VS
    Rand, ML
    [J]. THROMBOSIS AND HAEMOSTASIS, 1997, : PS300 - PS300
  • [6] EVALUATION OF THE FUNCTION OF DONOR PLATELETS USING A PLATELET FUNCTION ANALYZER PFA-100
    Han, K.
    Choi, J.
    Kim, H.
    [J]. VOX SANGUINIS, 2009, 97 : 38 - 38
  • [7] Platelet function during pregnancy : An evaluation with PFA-100 analyzer
    Nathan, N
    Vincelot, A
    Julia, A
    Collet, D
    Grandchamp, P
    [J]. ANESTHESIOLOGY, 2000, 93 (3A) : U215 - U215
  • [8] Platelet function analyzer (PFA-100)™ closure time in the evaluation of platelet disorders and platelet function:: a rebuttal
    Serebruany, V. L.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2006, 4 (06) : 1428 - 1429
  • [9] Platelet function in preeclampsia: Platelet function analyzer (PFA-100) vs TEG
    Davies, J
    Fernando, R
    Hallworth, S
    [J]. ANESTHESIOLOGY, 2001, 94 (1A)
  • [10] Platelet dysfunction in primary thrombocythemia using the platelet function analyzer, PFA-100
    Cesar, JM
    de Miguel, D
    Avello, AG
    Burgaleta, C
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2005, 123 (05) : 772 - 777