Distraction forces on repaired bucket-handle lesions in the medial meniscus

被引:38
|
作者
Becker, Roland
Brettschneider, Olaf
Groebel, Karl-Heinz
von Versen, Ruediger
Staerke, Christian
机构
[1] City Hosp Brandenburg, Dept Orthopaed & Traumatol, D-14770 Brandenburg, Germany
[2] Otto Von Guericke Univ, Dept Orthopaed, Magdeburg, Germany
[3] Johanniter Hosp, Dept Anaesthesia, Stendal, Germany
[4] Otto Von Guericke Univ, Inst Mech, Magdeburg, Germany
[5] German Inst Cell & Tissue Transplantat, Berlin, Germany
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2006年 / 34卷 / 12期
关键词
knee joint; meniscus lesion; human; biomechanics;
D O I
10.1177/0363546506290667
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Numerous studies have investigated the biomechanical properties of meniscal repair techniques. One of the most commonly discussed parameters is the failure load in the axis of insertion, although little is known about the distraction forces actually occurring at repaired bucket-handle lesions. Hypothesis: There are clinically relevant distraction forces on repaired meniscus bucket-handle lesions. Study Design: Controlled laboratory study. Methods: Meniscus bucket-handle lesions were created and repaired in human cadaveric knees with a vertical suture made from a braided steel wire. A small-sized load sensor was connected to the wire at the periphery of the meniscus. The distraction forces acting on the lesion were measured at different knee joint angles (0 degrees-120 degrees of flexion) with internal and external rotation and with and without weight loading. Forces in excess of 10 N were considered to have clinical relevance. Results: Mean forces on the meniscus repair ranged from 1.64 to 4.72 N.. Irrespective of the modalities (ie, different flexion angles, weight load, direction of rotation), it was found that the forces were well below the cutoff value of 10 N (P <.01). Increasing flexion angles generally did not cause an increase in distraction forces. Conclusion: The data suggest that distraction forces are riot the primary factor in the mechanical stability of meniscal repair. It must therefore be assumed that other factors such as shear forces are of greater significance. Clinical Relevance: The results may help to validate the biomechanical properties of different, meniscal repair techniques.
引用
收藏
页码:1941 / 1947
页数:7
相关论文
共 50 条
  • [1] BUCKET-HANDLE TEAR OF MEDIAL MENISCUS
    CARGILL, AOR
    JACKSON, JP
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (02): : 248 - 251
  • [2] MR IMAGING OF DISPLACED BUCKET-HANDLE TEAR OF THE MEDIAL MENISCUS
    SINGSON, RD
    FELDMAN, F
    STARON, R
    KIERNAN, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (01) : 121 - 124
  • [3] Clinical outcomes following surgically repaired bucket-handle meniscus tears
    Moses, Michael J.
    Wang, David E.
    Weinberg, Maxwell
    Strauss, Eric J.
    PHYSICIAN AND SPORTSMEDICINE, 2017, 45 (03): : 329 - 336
  • [4] The double ACL sign: an unusual bucket-handle tear of medial meniscus
    Takayama, Koji
    Matsushita, Takehiko
    Matsumoto, Tomoyuki
    Kubo, Seiji
    Kurosaka, Masahiro
    Kuroda, Ryosuke
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (08) : 1343 - 1346
  • [5] Outcomes After Repair of Chronic Bucket-Handle Tears of Medial Meniscus
    Espejo-Reina, Alejandro
    Serrano-Fernandez, Jose Miguel
    Martin-Castilla, Belen
    Estades-Rubio, Francisco Javier
    Briggs, Karen K.
    Espejo-Baena, Alejandro
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (04): : 492 - 496
  • [6] Arthroscopic Treatment of a "Bucket-Handle Like Tear" Lesion of the Medial Meniscus
    Kouzelis, Antonis
    Solou, Konstantina
    Panagopoulos, Andreas
    Kokkalis, Zinon
    Gliatis, John
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [7] The double ACL sign: an unusual bucket-handle tear of medial meniscus
    Koji Takayama
    Takehiko Matsushita
    Tomoyuki Matsumoto
    Seiji Kubo
    Masahiro Kurosaka
    Ryosuke Kuroda
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 1343 - 1346
  • [8] DISPLACED BUCKET-HANDLE TEARS OF THE MEDIAL MENISCUS MASKING ANTERIOR CRUCIATE DEFICIENCY
    KONG, KC
    HAMLET, MR
    PECKHAM, T
    MOWBRAY, MAS
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1994, 114 (01) : 51 - 52
  • [9] Bucket-handle tear of the medial plica
    Gerbino, PG
    Micheli, LJ
    CLINICAL JOURNAL OF SPORT MEDICINE, 1996, 6 (04): : 265 - 268
  • [10] Bucket-Handle Tear of the Medial Meniscus in a 2-Year-Old Child
    不详
    ORTHOPEDICS, 2018, 41 (04) : E580 - E582