Long-Term Electrocardiographic Follow-Up after Repair of Tetralogy of Fallot

被引:10
|
作者
Massin, Martial M. [1 ]
Malekzadeh-Milani, Sophie G. [1 ]
Schifflers, Stefan [1 ]
Dessy, Hugues [1 ]
Verbeet, Thierry [2 ]
机构
[1] Queen Fabiola Childrens Univ Hosp HUDERF, Div Pediat Cardiol, B-1020 Brussels, Belgium
[2] Free Univ Brussels ULB, Univ Hosp Brugmann, Dept Cardiol, Brussels, Belgium
关键词
conduction disorders; follow-up; congenital heart disease; tetralogy of Fallot; PULMONARY VALVE-REPLACEMENT; QRS DURATION; SUDDEN-DEATH; BLOCK; PROLONGATION; ARRHYTHMIA; CHILDREN; RISK;
D O I
10.1111/j.1542-474X.2011.00460.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Fallot patients with conduction disturbances are prone to sudden cardiac death. However, knowledge about long-term electrocardiographic changes after Fallot repair is limited. Methods: Measurements were performed on electrocardiograms recorded preoperatively, postoperatively, and during annual follow-up in 35 Fallot patients included in three groups: G1 if they received no patch (n = 7), G2 if they received a transannular patch (n = 13), and G3 if they received a pulmonary homograft (n = 15). Results: PR interval increased over the study period in all groups (Z-score: from 0.9 +/- 1.1 to 1.3 +/- 0.9 in G1, 0.9 +/- 1.2 to 1.7 +/- 1.6 in G2, and 0.7 +/- 0.7 to 1.4 +/- 1.3 in G3). The QRS duration increased during the follow-up at a rate of 1.78 msec/year in G1, 2.34 msec/year in G2 despite pulmonary valve replacement in 10 patients, and 1.81 msec/year in G3 despite conduit replacement in 9. At the later follow-up, the QRS duration was significantly increased (Z = 4.5 +/- 3.6 in G1, 5.7 +/- 1.4 in G2, and 4.6 +/- 1.9 in G3). One patient in each group had QRS duration of 170 msec or longer and the one in G3 had a history of serious ventricular arrhythmia. Three patients had a QTc duration above 460 msec. Conclusions: Progressive conduction disorders are noted during long-term follow-up in Fallot patients who received transannular patch but also in those who received no patch or a pulmonary homograft. It suggests that volume overloading related to the transannular patch but also pressure overloading and myocardial injury related to surgery contribute to their development. Ann Noninvasive Electrocardiol 2011; 16(4): 336-343
引用
下载
收藏
页码:336 / 343
页数:8
相关论文
共 50 条
  • [1] Long-term follow-up in adults after tetralogy of Fallot repair
    Natalia Dłużniewska
    Piotr Podolec
    Maciej Skubera
    Monika Smaś-Suska
    Jacek Pająk
    Małgorzata Urbańczyk-Zawadzka
    Wojciech Płazak
    Maria Olszowska
    Lidia Tomkiewicz-Pająk
    Cardiovascular Ultrasound, 16
  • [2] Long-term follow-up in adults after tetralogy of Fallot repair
    Dluzniewska, Natalia
    Podolec, Piotr
    Skubera, Maciej
    Smas-Suska, Monika
    Pajak, Jacek
    Urbanczyk-Zawadzka, Malgorzata
    Plazak, Wojciech
    Olszowska, Maria
    Tomkiewicz-Pajak, Lidia
    CARDIOVASCULAR ULTRASOUND, 2018, 16
  • [3] Follow-up of tetralogy of Fallot after repair
    Van Aerschot, Isabelle
    Iserin, Laurence
    PRESSE MEDICALE, 2011, 40 (7-8): : 740 - 747
  • [4] Late complications following tetralogy of fallot repair: The need for long-term follow-up
    Ho, Kay Woon
    Tan, Ru San
    Wong, Keng Yean
    Tan, Teng Hong
    Shankar, Sriram
    Tan, Ju Le
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2007, 36 (11) : 947 - 953
  • [5] Long-term follow-up after transatrial-transpulmonary repair of tetralogy of Fallot: influence of timing on outcome
    van den Bosch, Eva
    Bogers, Ad J. J. C.
    Roos-Hesselink, Jolien W.
    van Dijk, Arie P. J.
    van Wijngaarden, Marie H. E. J.
    Boersma, Eric
    Nijveld, Aagje
    Luijten, Linda W. G.
    Tanke, Ronald
    Koopman, Laurens P.
    Helbing, Willem A.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 57 (04) : 635 - 643
  • [6] ELECTROPHYSIOLOGIC STUDY OF PATIENTS WITH VENTRICULAR DYSRHYTHMIAS DURING LONG-TERM FOLLOW-UP AFTER REPAIR OF TETRALOGY OF FALLOT
    SATOH, M
    AIZAWA, Y
    MURATA, M
    SUZUKI, K
    AIZAWA, M
    FUNAZAKI, T
    SHIBATA, A
    MIYAMURA, H
    EGUCHI, S
    MATSUKAWA, T
    JAPANESE HEART JOURNAL, 1988, 29 (01): : 69 - 77
  • [7] Long-Term Follow-Up After Pulmonary Valve Replacement in Repaired Tetralogy of Fallot
    Sabate Rotes, Anna
    Eidem, Benjamin W.
    Connolly, Heidi M.
    Bonnichsen, Crystal R.
    Rosedahl, Jordan K.
    Schaff, Hartzell V.
    Dearani, Joseph A.
    Burkhart, Harold M.
    AMERICAN JOURNAL OF CARDIOLOGY, 2014, 114 (06): : 901 - 908
  • [8] LONG-TERM PSYCHOLOGICAL FOLLOW-UP OF PATIENTS AFTER CORRECTIVE SURGERY FOR TETRALOGY OF FALLOT
    BAER, PE
    FREEDMAN, DA
    GARSON, A
    JOURNAL OF THE AMERICAN ACADEMY OF CHILD AND ADOLESCENT PSYCHIATRY, 1984, 23 (05): : 622 - 625
  • [9] Postoperative assessment of a modified surgical approach to repair of tetralogy of Fallot - Long-term follow-up
    AtallahYunes, NH
    Kavey, REW
    Bove, EL
    Smith, FC
    Kveselis, DA
    Byrum, CJ
    Gaum, WE
    CIRCULATION, 1996, 94 (09) : 22 - 26
  • [10] POSTOPERATIVE ASSESSMENT OF A MODIFIED SURGICAL APPROACH TO REPAIR OF TETRALOGY OF FALLOT - LONG-TERM FOLLOW-UP
    ATALLAHYUNES, NH
    KAVEY, REW
    BOVE, EL
    SMITH, FC
    BYRUM, CJ
    KVESELIS, DA
    GAUM, WE
    CIRCULATION, 1995, 92 (08) : 1173 - 1173