An automated quasi-continuous capillary refill timing device

被引:24
|
作者
Blaxter, L. L. [1 ]
Morris, D. E. [1 ]
Crowe, J. A. [1 ]
Henry, C. [2 ]
Hill, S. [2 ]
Sharkey, D. [2 ]
Vyas, H. [2 ]
Hayes-Gill, B. R. [1 ]
机构
[1] Univ Nottingham, Fac Engn, Elect Syst & Opt Res Div, Nottingham NG7 2RD, England
[2] Queens Med Ctr, Acad Child Hlth, Sch Med, Nottingham NG7 2UH, England
基金
英国医学研究理事会;
关键词
capillary refill time; automation; sensor; monitoring; TIME; TEMPERATURE; SYSTEM;
D O I
10.1088/0967-3334/37/1/83
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of the skin surface. There is evidence to suggest that manually assessed CRT is subject to bias from ambient light conditions, a lack of standardisation of both blanching time and manually applied pressure, subjectiveness of return to normal colour, and variability in the manual assessment of time. We present a novel automated system for CRT measurement, incorporating three components: a non-invasive adhesive sensor incorporating a pneumatic actuator, a diffuse multi-wavelength reflectance measurement device, and a temperature sensor; a battery operated datalogger unit containing a self contained pneumatic supply; and PC based data analysis software for the extraction of refill time, patient skin surface temperature, and sensor signal quality. Through standardisation of the test, it is hoped that some of the shortcomings of manual CRT can be overcome. In addition, an automated system will facilitate easier integration of CRT into electronic record keeping and clinical monitoring or scoring systems, as well as reducing demands on clinicians. Summary analysis of volunteer (n = 30) automated CRT datasets are presented, from 15 healthy adults and 15 healthy children (aged from 5 to 15 years), as their arms were cooled from ambient temperature to 5 degrees C. A more detailed analysis of two typical datasets is also presented, demonstrating that the response of automated CRT to cooling matches that of previously published studies.
引用
收藏
页码:83 / 99
页数:17
相关论文
共 50 条
  • [1] CONTINUOUS AND QUASI-CONTINUOUS MODULES
    SMITH, PF
    TERCAN, A
    [J]. HOUSTON JOURNAL OF MATHEMATICS, 1992, 18 (03): : 339 - 348
  • [2] ON QUASI-CONTINUOUS RINGS
    NICHOLSON, WK
    YOUSIF, MF
    [J]. PROCEEDINGS OF THE AMERICAN MATHEMATICAL SOCIETY, 1994, 120 (04) : 1049 - 1051
  • [3] Quasi-continuous histograms
    Strauss, Olivier
    [J]. FUZZY SETS AND SYSTEMS, 2009, 160 (17) : 2442 - 2465
  • [4] AUTOMATED QUASI-CONTINUOUS IMMUNOANALYSIS OF PESTICIDES WITH A FLOW-INJECTION SYSTEM
    KRAMER, PM
    SCHMID, RD
    [J]. PESTICIDE SCIENCE, 1991, 32 (04): : 451 - 462
  • [5] CONTINUOUS MODULES AND QUASI-CONTINUOUS MODULES
    OSHIRO, K
    [J]. OSAKA JOURNAL OF MATHEMATICS, 1983, 20 (03) : 681 - 694
  • [6] MODULES AND QUASI-CONTINUOUS RINGS
    JEREMY, L
    [J]. COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES SERIE A, 1971, 273 (02): : 80 - &
  • [7] Modules with quasi-continuous submodules
    Al-Saadi, Saad Abdulkadhim
    [J]. Italian Journal of Pure and Applied Mathematics, 2022, 48 : 22 - 31
  • [8] The model of the quasi-continuous fragmentation
    Kuznetsov, VL
    Novikov, GG
    [J]. PROCEEDINGS OF THE METEOROIDS 2001 CONFERENCE, 2001, 495 : 255 - 258
  • [9] Modules with quasi-continuous submodules
    Al-Saadi, Saad Abdulkadhim
    [J]. ITALIAN JOURNAL OF PURE AND APPLIED MATHEMATICS, 2022, (48): : 22 - 31
  • [10] Modules with quasi-continuous submodules
    Al-Saadi, Saad Abdulkadhim
    [J]. ITALIAN JOURNAL OF PURE AND APPLIED MATHEMATICS, 2023, (48): : 22 - 31