Absorption Efficiency Assessment and Uncertainty Measurement of the Sodium Arsenite Method for Ambient NO2 Determination

被引:4
|
作者
Agarwal, Rishu [1 ,2 ]
Aggarwal, Shankar G. [1 ,2 ]
机构
[1] CSIR, Acad Sci & Innovat Res AcSIR, Natl Phys Lab Campus, New Delhi 110012, India
[2] Natl Phys Lab, Environm Sci & Biomed Metrol Div, CSIR, New Delhi 110012, India
关键词
Gaseous NO2 pollution; Sodium arsenite method; Absorption efficiency; Measurement uncertainty; NITROGEN-DIOXIDE;
D O I
10.4209/aaqr.200583
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The absorption efficiency and uncertainty involved in the sodium arsenite method (modified Jacobs and Hochheiser method) of NO2 measurement were studied using two standard gas concentrations (4.86 +/- 0.10 mu mol mol(-1) (ppm) and 1.95 +/- 0.10 mu mol mol(-1) (ppm)). An average of 71 +/- 3% and 71 +/- 6% absorption efficiencies, respectively were observed against reported efficiency of 82% in the published standard (IS 5182 (Part 6): 2006, BIS, 2006a) in 1-impinger system at sampling flow rate of 1 L min(-1) and absorbing solution temperature of 10-15 degrees C during gas absorption in impinger. The difference is accounted for by the variation in flow rate used in present study (1 L min(-1)) and that in standard method (0.2 L min(-1)). Uncertainty involved in the method was calculated considering a range of factors directly or indirectly affecting the measurement and was found to be 15%. Based on the comparison study performed for NO2 ambient measurements using an equivalent method (chemiluminescence continuous method) and 1-impinger system reference method, the present study highlights the importance of accurate determination of absorption efficiency factor in the NO2 pollutant measurement at laboratory level. Variations observed in the absorption efficiency and the data from inter-comparison study between manual and real-time method warranted this study to be taken up to provide solutions for improvement of the method. The use of at least three absorbers/impingers (connected in series) instead of one to obtain absorption efficiency close to unity is proposed to make the reference method independent from the use of absorption efficiency factor thus ensuring the improved data quality and comparability.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条
  • [1] EVALUATION OF SODIUM ARSENITE METHOD FOR MEASUREMENT OF NO2 IN AMBIENT AIR
    MARGESON, JH
    BEARD, ME
    SUGGS, JC
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1977, 27 (06): : 553 - 556
  • [2] Effect of temperature on absorption efficiency of NO2 in arsenite method
    Goyal, SK
    Gavane, AG
    Aggarwal, AL
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2000, 61 (02) : 283 - 289
  • [3] Effect of Temperature on Absorption Efficiency of NO2 in Arsenite Method
    S. K. Goyal
    A. G. Gavane
    A. L. Aggarwal
    Environmental Monitoring and Assessment, 2000, 61 (2) : 285 - 291
  • [4] Effect of sample flow rate and sampling duration on the absorption of NO2 in the sodium arsenite monitoring method
    Goyal, SK
    JOURNAL OF ENVIRONMENTAL MONITORING, 2002, 4 (04): : 579 - 582
  • [5] Assessment of Uncertainty in Ambient NO2 Concentration Determination and its Minimization through Application of Lab Scale Findings
    Goyal S.K.
    Chavhan C.D.
    Journal of The Institution of Engineers (India): Series A, 2015, 96 (2) : 131 - 137
  • [6] COLLABORATIVE TESTING OF A MANUAL SODIUM ARSENITE METHOD FOR MEASUREMENT OF NITROGEN-DIOXIDE IN AMBIENT AIR
    MARGESON, JH
    SUGGS, JC
    CONSTANT, PC
    SHARP, MC
    SCHEIL, GW
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1978, 12 (03) : 294 - 297
  • [7] AN ASSESSMENT OF THE LUMINOL CHEMILUMINESCENCE TECHNIQUE FOR MEASUREMENT OF NO2 IN AMBIENT AIR
    KELLY, TJ
    SPICER, CW
    WARD, GF
    ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1990, 24 (09): : 2397 - 2403
  • [8] Assessment of uncertainty of NO2 measurements by the chemiluminescence method and discussion of the quality objective of the NO2 European Directive
    Gerboles, M
    Lagler, F
    Rembges, D
    Brun, C
    JOURNAL OF ENVIRONMENTAL MONITORING, 2003, 5 (04): : 529 - 540
  • [9] Standardisation of a European reference measurement method for the determination of Pb, As, Cd and Ni in ambient air - Validation and determination of the measurement uncertainty
    Berger, K
    Bunzel, F
    Neuroth, R
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2003, 63 (04): : 157 - 162
  • [10] Motor Efficiency Determination of SynRM and Measurement Uncertainty
    Kim, Youn-Hwan
    Jun, Hee-Deuk
    Moon, Jae-Won
    Kim, Rae-Eun
    Rhyu, Se-Hyun
    Jung, Sang-Young
    2019 INTERNATIONAL AEGEAN CONFERENCE ON ELECTRICAL MACHINES AND POWER ELECTRONICS (ACEMP) & 2019 INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT (OPTIM), 2019, : 233 - 239