Calibration of photonis XP3062/FL photomultiplier tube

被引:0
|
作者
Xiao, G. [1 ]
Zhang, Y. [1 ]
Baib, Y. [1 ]
Cao, Z. [1 ]
机构
[1] SW Jiaotong Univ China, Chengdu 610031, Peoples R China
关键词
D O I
暂无
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The absolute gain, linearity, photo-cathode response as a function of location and wavelength of PMT Photonis XP3062/FL is measured in this paper. The relative gain of the PMT as a function of the high voltage (HV) is calibrated from 600V to 2200V The absolute gain of the PMT at 2000V is measured by using the single photoelectron technique. Based on these measurements, the working high voltage at 1300V is determined. The linearity of the PMT over 3.5 orders of magnitudes is calibrated. The PMT's response to different wavelength light sources is measured from 200 similar to 500mn. The location dependence of the photocathode is measured by using a light source (UV LED) to scan the surface of the photocathode millimeter by millimeter.
引用
收藏
页码:21 / 24
页数:4
相关论文
共 16 条
  • [1] A photomultiplier tube test stand and on-site measurements to characterise the performance of Photonis XP3062 photomultiplier tubes at increased background light conditions and lower gain
    Zorn, J.
    Daumiller, K.
    Engel, R.
    Mathes, H-J
    Riegel, M.
    Smida, R.
    Werner, F.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 938 : 20 - 28
  • [2] Evaluation of new Photonis XP1472 nine-channel photomultiplier
    Moszynski, M
    Wolski, D
    Kapusta, M
    Balcerzyk, M
    Syntfeld, A
    Fontaine, C
    Lavoute, P
    Bascle, P
    Moussant, C
    Flyckt, SO
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1615 - 1620
  • [3] Evaluation of new photonis XP1472 nine-channel photomultiplier
    Moszynski, M
    Kapusta, A
    Wolski, D
    Balcerzyk, M
    Syntfeld, A
    Fontaine, C
    Lavoute, P
    Bascle, P
    Moussant, C
    Flyckt, SO
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 1027 - 1032
  • [4] Study of photonis XP1470 nine-channel photomultiplier tube for applications in high resolution single gamma and PET imagers
    Popov, Vladimir
    Majewski, Stan
    Proffitt, James
    McKisson, John
    Kross, Brian
    Weisenberger, Andrew
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2870 - 2874
  • [5] New Photonis XP20D0 photomultiplier for fast timing in nuclear medicine
    Moszynskia, M.
    Gierlik, M.
    Kapusta, M.
    Nassalski, A.
    Szczesniak, T.
    Fontaine, Ch.
    Lavoute, P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 567 (01): : 31 - 35
  • [6] An analytical model for photomultiplier tube calibration
    Kalousis, Leonidas N.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1058
  • [7] Calibration and characterization of the IceCube photomultiplier tube
    Abbasi, R.
    Abdou, Y.
    Abu-Zayyad, T.
    Adams, J.
    Aguilar, J. A.
    Ahlers, M.
    Andeen, K.
    Auffenberg, J.
    Bai, X.
    Baker, M.
    Barwick, S. W.
    Bay, R.
    Alba, J. L. Bazo
    Beattie, K.
    Beatty, J. J.
    Bechet, S.
    Becker, J. K.
    Becker, K. -H.
    Benabderrahmane, M. L.
    Berdermann, J.
    Berghaus, P.
    Berley, D.
    Bernardini, E.
    Bertrand, D.
    Besson, D. Z.
    Bissok, M.
    Blaufuss, E.
    Boersma, D. J.
    Bohm, C.
    Botner, O.
    Bradley, L.
    Braun, J.
    Buitink, S.
    Carson, M.
    Chirkin, D.
    Christy, B.
    Clem, J.
    Cohen, S.
    Colnard, C.
    Cowen, D. F.
    D'Agostino, M. V.
    Danninger, M.
    De Clercq, C.
    Demiroers, L.
    Depaepe, O.
    Descamps, F.
    Desiati, P.
    de Vries-Uiterweerd, G.
    DeYoung, T.
    Diaz-Velez, J. C.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 618 (1-3): : 139 - 152
  • [8] A SIMPLE METHOD OF PHOTOMULTIPLIER TUBE CALIBRATION
    LEIBOVITZ, C
    KASHA, H
    [J]. BULLETIN OF THE RESEARCH COUNCIL OF ISRAEL, 1962, F 10 (03): : 146 - &
  • [9] The 75 mm diameter photonis XP43D2 photomultiplier with the screening grid at the anode for timing experiments
    Szczesniak, T.
    Gierlik, M.
    Kapusta, M.
    Moszynski, M.
    Wolski, D.
    Lavoute, P.
    Rossignol, E.
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 729 - 734
  • [10] The photomultiplier tube calibration system of the MicroBooNE experiment
    Conrad, J.
    Jones, B. J. P.
    Moss, Z.
    Strauss, T.
    Toups, M.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10