Liquid Cooling in Data Centers

被引:0
|
作者
Cader, Tahir [1 ]
Sorel, Vali [1 ]
Westra, Levi [1 ]
Marquez, Andres [1 ]
机构
[1] SprayCool, Liberty Lake, WA USA
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Semiconductor manufacturers have aggressively attacked the problem of escalating microprocessor power consumption levels. Today, server manufacturers can purchase microprocessors that currently have power consumption levels capped at 341.2 BTU/hr (100 W) maximum. However total server power levels continue to increase, with the increase in power consumption coming from the supporting chipsets, memory, and other components. In turn, full rack heat loads are very aggressively climbing as well, and this is making it increasingly difficult and cost-prohibitive for facility owners to cool these high power racks. As a result, facilities owners are turning to alternative, and more energy efficient, cooling solutions that deploy liquids in one form or another. The paper discusses the advent of the adoption of liquid-cooling in high performance computing centers. Preparation for a liquid-cooled data center, retrofit and green field (new), is discussed herein, with a focus on the key issues that are common to all liquid-cooling technologies that depend upon the delivery of water to the rack (or in some deployments, a Coolant Distribution Unit). The paper then discusses, in some detail, the actual implementation and deployment of a liquid device-level cooled (spray cooled) supercomputer at the Pacific Northwest National Laboratory Initial results from a successful 30 day compliance test show excellent hardware stability, operating system (OS) and software stack stability, application stability and performance, and an availability level that exceeded expectations at 99.94%. The liquid-cooled supercomputer achieved a peak performance of 9.287 Tera-Flops, which placed it at number 101 in the June 2007 Top500 fastest supercomputers worldwide. Long-term performance and energy efficiency testing is currently underway, and detailed results will be reported in up coming publications.
引用
收藏
页码:231 / +
页数:2
相关论文
共 50 条
  • [1] LIQUID COOLING FOR THERMAL MANAGEMENT OF DATA CENTERS
    Mulay, Veerendra
    Agonafer, Dereje
    Schmidt, Roger
    [J]. IMECE2008: PROCEEDINGS OF THE INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2008, VOL 6, 2009, : 95 - 101
  • [2] Liquid Cooling in Data Centers, Part 2
    Sorell, Vali
    Tuma, Phil
    Newcombe, Liam
    [J]. 2013 ASHRAE ANNUAL CONFERENCE, 2013,
  • [3] Liquid-Cooling Trends In Data Centers
    Beaty, Donald L.
    Quirk, David
    Morrison, Frank T.
    [J]. ASHRAE JOURNAL, 2019, 61 (07) : 56 - 62
  • [4] Liquid-cooling trends in data centers
    Beaty, Donald L.
    Quirk, David
    Morrison, Frank T.
    [J]. ASHRAE Journal, 2019, 61 (06) : 56 - 62
  • [5] Liquid cooling of data centers: A necessity facing challenges
    Azarifar, Mohammad
    Arik, Mehmet
    Chang, Je -Young
    [J]. APPLIED THERMAL ENGINEERING, 2024, 247
  • [6] LIQUID TO LIQUID COOLING FOR HIGH HEAT DENSITY LIQUID COOLED DATA CENTERS
    Heydari, Ali
    Shahi, Pardeep
    Radmard, Vahideh
    Eslami, Bahareh
    Chowdhury, Uschas
    Saini, Satyam
    Bansode, Pratik
    Miyamura, Harold
    Agonafer, Dereje
    Rodriguez, Jeremy
    [J]. PROCEEDINGS OF ASME 2022 INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, INTERPACK2022, 2022,
  • [7] FACILITY COOLING FAILURE ANALYSIS OF DIRECT LIQUID COOLING SYSTEM IN DATA CENTERS
    Alkharabsheh, Sami
    Puvvadi, Udaya L. N.
    Ramakrishnan, Bharath
    Ghose, Kanad
    Sammakia, Bahgat
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, 2018, 2019,
  • [8] FAILURE ANALYSIS OF DIRECT LIQUID COOLING SYSTEM IN DATA CENTERS
    Alkharabsheh, Sami
    Ramakrishnan, Bharath
    Sammakia, Bahgat
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, 2017, 2017,
  • [9] LIQUID COOLING NETWORK SYSTEMS FOR ENERGY CONSERVATION IN DATA CENTERS
    Ouchi, Mayumi
    Abe, Yoshiyuki
    Fukagaya, Masato
    Ohta, Haruhiko
    Shinmoto, Yasuhisa
    Sato, Masahide
    Iimura, Ken-ichi
    [J]. PROCEEDINGS OF THE ASME PACIFIC RIM TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC SYSTEMS, MEMS AND NEMS 2011, VOL 2, 2012, : 443 - +
  • [10] Failure Analysis of Direct Liquid Cooling System in Data Centers
    Alkharabsheh, Sami
    Puvvadi, Udaya L. N.
    Ramakrishnan, Bharath
    Ghose, Kanad
    Sammakia, Bahgat
    [J]. JOURNAL OF ELECTRONIC PACKAGING, 2018, 140 (02)